Blood Pressure Measurement Anno 2016
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
The rational management of hypertension (HT) inevitably starts with accurate measurement of blood pressure (BP). The recently published Systolic Blood Pressure Intervention Trial implemented automated office BP measurement. However, event-driven studies have overwhelmingly indicated that out-of-the-office BP monitoring is a prerequisite for risk stratification and for identifying the need of initiating or adjusting antihypertensive drug treatment. 24-Hour ambulatory BP monitoring is the preferred method of BP measurement and addresses major issues not covered by conventional or automated office BP measurement or home BP monitoring, such as reliably diagnosing nocturnal HT (the time window of the day during which BP is most predictive of adverse cardiovascular outcome), hypotension, or masked HT, a condition that affects 15% of the general populations and carries a risk equal to that of HT on both office and out-of-the-office BP measurement. Moreover, 24-hour ambulatory BP monitoring is cost-effective. Outcome-driven criteria support single BP thresholds that can be applied in both sexes and across the age range. In conclusion, the overall evidence now overwhelmingly shows that ambulatory BP monitoring is mandatory for the proper management of HT. Health care providers should therefore facilitate access to this technique in both primary and specialized care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Randomized Trial of Intensive versus Standard Blood-Pressure Control
The SPRINT Research Group (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1511939 · Cited by 6,325
O'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., et al. (2003) · Journal of Hypertension · doi:10.1097/00004872-200305000-00001 · Cited by 1,655
Self-citationStaessen, J. A. (1999) · JAMA · doi:10.1001/jama.282.6.539 · Cited by 1,592
Self-citationEuropean Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Self-citationDolan, E., Stanton, A., Thijs, L., Hinedi, K., Atkins, N., McClory, S., Hond, E. D., McCormack, P., Staessen, J. A., & O’Brien, E. (2005) · Hypertension · doi:10.1161/01.hyp.0000170138.56903.7a · Cited by 1,227
Self-citationGBD 2010: design, definitions, and metrics
Murray, C. J., Ezzati, M., Flaxman, A. D., Lim, S., Lozano, R., Michaud, C., Naghavi, M., Salomon, J. A., Shibuya, K., Vos, T., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61899-6 · Cited by 1,103
Prognostic Value of Ambulatory Blood-Pressure Recordings in Patients with Treated Hypertension
Clement, D. L., De Buyzere, M. L., De Bacquer, D. A., de Leeuw, P. W., Duprez, D. A., Fagard, R. H., Gheeraert, P. J., Missault, L. H., Braun, J. J., Six, R. O., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022273 · Cited by 1,085
Self-citationPrognostic accuracy of day versus night ambulatory blood pressure: a cohort study
Boggia, J., Li, Y., Thijs, L., Hansen, T. W., Kikuya, M., Björklund-Bodegård, K., Richart, T., Ohkubo, T., Kuznetsova, T., Torp-Pedersen, C., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61538-4 · Cited by 887
Self-citationNiiranen, T. J., Hänninen, M.-R., Johansson, J., Reunanen, A., & Jula, A. M. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.149336 · Cited by 390
Ben-Dov, I. Z., Kark, J. D., Ben-Ishay, D., Mekler, J., Ben-Arie, L., & Bursztyn, M. (2007) · Hypertension · doi:10.1161/hypertensionaha.107.087262 · Cited by 367
Diagnostic Thresholds for Ambulatory Blood Pressure Monitoring Based on 10-Year Cardiovascular Risk
Kikuya, M., Hansen, T. W., Thijs, L., Björklund-Bodegård, K., Kuznetsova, T., Ohkubo, T., Richart, T., Torp-Pedersen, C., Lind, L., Ibsen, H., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.662254 · Cited by 314
Self-citationLovibond, K., Jowett, S., Barton, P., Caulfield, M., Heneghan, C., Hobbs, F. R., Hodgkinson, J., Mant, J., Martin, U., Williams, B., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)61184-7 · Cited by 311
Staessen, J. A. (2004) · JAMA · doi:10.1001/jama.291.8.955 · Cited by 288
Self-citationMeasurement of Blood Pressure in the Office: Recognizing the Problem and Proposing the Solution
Myers, M. G., Godwin, M., Dawes, M., Kiss, A., Tobe, S. W., & Kaczorowski, J. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.141879 · Cited by 260
Masked Hypertension in Diabetes Mellitus: Treatment Implications for Clinical Practice
Franklin, S. S., Thijs, L., Li, Y., Hansen, T. W., Boggia, J., Liu, Y., Asayama, K., Björklund-Bodegård, K., Ohkubo, T., Jeppesen, J., et al. (2013) · Hypertension · doi:10.1161/hypertensionaha.111.00289 · Cited by 167
Self-citationParati, G., Omboni, S., Albini, F., Piantoni, L., Giuliano, A., Revera, M., Illyes, M., & Mancia, G. (2009) · Journal of Hypertension · doi:10.1097/hjh.0b013e3283163caf · Cited by 166
Niiranen, T. J., Asayama, K., Thijs, L., Johansson, J. K., Ohkubo, T., Kikuya, M., Boggia, J., Hozawa, A., Sandoya, E., Stergiou, G. S., et al. (2013) · Hypertension · doi:10.1161/hypertensionaha.111.00100 · Cited by 120
Self-citationHome Self Blood Pressure Measurement in General Practice The SMART Study
Chatellier, G. (1996) · American Journal of Hypertension · doi:10.1016/0895-7061(96)00018-0 · Cited by 116
Asayama, K., Thijs, L., Brguljan-Hitij, J., Niiranen, T. J., Hozawa, A., Boggia, J., Aparicio, L. S., Hara, A., Johansson, J. K., Ohkubo, T., et al. (2014) · PLoS Medicine · doi:10.1371/journal.pmed.1001591 · Cited by 87
Self-citationHara, A., Tanaka, K., Ohkubo, T., Kondo, T., Kikuya, M., Metoki, H., Hashimoto, T., Satoh, M., Inoue, R., Asayama, K., et al. (2012) · Hypertension · doi:10.1161/hypertensionaha.111.174938 · Cited by 79
Self-citationStaessen, J. A., Thijs, L., Ohkubo, T., Kikuya, M., Richart, T., Boggia, J., Adiyaman, A., Dechering, D. G., Kuznetsova, T., Thien, T., et al. (2008) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3283108f93 · Cited by 56
Self-citationDefining Thresholds for Home Blood Pressure Monitoring in Octogenarians
Aparicio, L. S., Thijs, L., Boggia, J., Jacobs, L., Barochiner, J., Odili, A. N., Alfie, J., Asayama, K., Cuffaro, P. E., Nomura, K., et al. (2015) · Hypertension · doi:10.1161/hypertensionaha.115.05800 · Cited by 45
Self-citation
Cited by
Staplin, N., de la Sierra, A., Ruilope, L. M., Emberson, J. R., Vinyoles, E., Gorostidi, M., Ruiz-Hurtado, G., Segura, J., Baigent, C., & Williams, B. (2023) · The Lancet · doi:10.1016/s0140-6736(23)00733-x · Cited by 290
Wearable Devices for Precision Medicine and Health State Monitoring
Jeong, I. C., Bychkov, D., & Searson, P. C. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2871638 · Cited by 155
“Normal blood pressure for adults over 20 years of age is less than 120 mm Hg for the systolic pressure and less than 80 mm Hg for the diastolic pressure [103].”
Background(2022) · PubMed Central · doi:10.6515/acs.202205_38(3).20220321a · Cited by 117
Ambulatory blood pressure monitoring in the 21st century
O'Brien, E., White, W. B., Parati, G., & Dolan, E. (2018) · The Journal of Clinical Hypertension · doi:10.1111/jch.13275 · Cited by 66
“individual’s awake and asleep time intervals as reported by each individual; (2) summary statistics for BP and heart rate separately for the 24 h, the daytime (awake), the night-time (asleep), and the white-coat window periods; and (3) the raw BP data.”
BackgroundMethodSelf-citationPatterns of ambulatory blood pressure: clinical relevance and application
O'Brien, E., Kario, K., Staessen, J. A., de la Sierra, A., & Ohkubo, T. (2018) · The Journal of Clinical Hypertension · doi:10.1111/jch.13277 · Cited by 40
Self-citation
Metadata
- Authors
- Staessen, J. A., Li, Y., Hara, A., Asayama, K., Dolan, E., & O’Brien, E.
- Venue
- American Journal of Hypertension
- Publisher
- Oxford University Press (OUP)
- Published
- 2017-01-04
- Volume
- 30
- Issue
- 5
- Pages
- hpw148
- ISSN
- 0895-7061 (ISSN-L)
- 1941-7225
- OpenAlex
- W2569146144
- Cited by
- 76
- References
- 22
- FWCI
- 9.24
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.