Numerical Modeling of Turbulent and Laminar Airflow and Odorant Transport during Sniffing in the Human and Rat Nose
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Human sniffing behavior usually involves bouts of short, high flow rate inhalation (>300 ml/s through each nostril) with mostly turbulent airflow. This has often been characterized as a factor enabling higher amounts of odorant to deposit onto olfactory mucosa than for laminar airflow and thereby aid in olfactory detection. Using computational fluid dynamics human nasal cavity models, however, we found essentially no difference in predicted olfactory odorant flux (g/cm2 s) for turbulent versus laminar flow for total nasal flow rates between 300 and 1000 ml/s and for odorants of quite different mucosal solubility. This lack of difference was shown to be due to the much higher resistance to lateral odorant mass transport in the mucosal nasal airway wall than in the air phase. The simulation also revealed that the increase in airflow rate during sniffing can increase odorant uptake flux to the nasal/olfactory mucosa but lower the cumulative total uptake in the olfactory region when the inspired air/odorant volume was held fixed, which is consistent with the observation that sniff duration may be more important than sniff strength for optimizing olfactory detection. In contrast, in rats, sniffing involves high-frequency bouts of both inhalation and exhalation with laminar airflow. In rat nose odorant uptake simulations, it was observed that odorant deposition was highly dependent on solubility and correlated with the locations of different types of receptors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effect of Anatomy on Human Nasal Air Flow and Odorant Transport Patterns: Implications for Olfaction
Zhao, K. (2004) · Chemical Senses · doi:10.1093/chemse/bjh033 · Cited by 361 · cited 6×
“A 3D anatomically accurate finite volume nasal model (Zhao et al. , 2004) constructed from an axial CT of a healthy adult female (1-mm slices, 512 · 512 pixels, pixel size = 1.0 · 0.3906 · 0.3906 mm) that includes both sides of the human nasal cavity and the nasopharynx was used in this study.”
InfluentialSelf-citationNumerical Simulation of Airflow in the Human Nasal Cavity
Keyhani, K., Scherer, P. W., & Mozell, M. M. (1995) · Journal of Biomechanical Engineering · doi:10.1115/1.2794204 · Cited by 360 · cited 7×
“Using Hahn’s experimental measurements for validation, Keyhani et al. (1995, 1997) developed a finite element numerical model of the right side of the human nasal cavity, obtained from the computerized axial tomography (CAT) scans used by Hahn to construct his large physical model and computed…”
InfluentialSelf-citationVelocity profiles measured for airflow through a large-scale model of the human nasal cavity
Hahn, I., Scherer, P. W., & Mozell, M. M. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.75.5.2273 · Cited by 355 · cited 4×
“The only available experimental measurements of turbulence intensity in the human nasal cavity are those obtained by Hahn et al. (1993) who studied both laminar and turbulent flows in a 20 · scaled anatomically accurate model based on coronal computerized tomography (CT) scan images.”
InfluentialSelf-citationRespiratory Defense Mechanisms.
(1978) · Annals of Internal Medicine · doi:10.7326/0003-4819-88-4-584_1 · Cited by 336
COMPUTATIONAL FLUID DYNAMICS SIMULATIONS OF INSPIRATORY AIRFLOW IN THE HUMAN NOSE AND NASOPHARYNX
Subramaniam, R. P., Richardson, R. B., Morgan, K. T., Kimbell, J. S., & Guilmette, R. A. (1998) · Inhalation Toxicology · doi:10.1080/089583798197772 · Cited by 269 · cited 1×
“Subramaniam et al. (1999) presented a similar model constructed from magnetic resonance imaging scans that included both sides of the human nasal passages and also the posterior nasal airway and nasopharynx.”
Detailed flow patterns in the nasal cavity
Kelly, J. T., Prasad, A. K., & Wexler, A. S. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.1.323 · Cited by 248 · cited 1×
“…measurement in these casts was made by visualizing smoke in airflow (Proetz, 1951), using miniature pitot tubes (Swift and Proctor, 1977), laser Doppler velocimetry (Girardin et al. , 1983), radioactive tracers (Hornung et al. , 1987), and particle image velocimetry (Kelly et al. , 2000).”
A quantitative analysis of sniffing strategies in rats performing odor detection tasks
Youngentob, S. L., Mozell, M. M., Sheehe, P. R., & Hornung, D. E. (1987) · Physiology & Behavior · doi:10.1016/0031-9384(87)90131-4 · Cited by 207 · cited 1×
“Typical physiological values (Youngentob et al. , 1987) are as follows: frequency 1.0–8 Hz, external nares hydraulic diameter ; 0.18 cm, nasal cavity length ; 3.0 cm, and average air velocity in nares, 70–380 cm/s.”
InfluentialComputer Simulation of Inspiratory Airflow in All Regions of the F344 Rat Nasal Passages
Kimbell, J. S., Godo, M. N., Gross, E. A., Joyner, D. R., Richardson, R. B., & Morgan, K. T. (1997) · Toxicology and Applied Pharmacology · doi:10.1006/taap.1997.8206 · Cited by 197 · cited 3×
“Although CFD has previously been applied to study airflow in the rat nose (Kimbell et al. , 1993, 1997), it was utilized primarily for the purposes of understanding the deposition pattern and nasal toxicity of various chemical agents and not to evaluate the impact of airflow on olfactory perception.”
A Numerical Model of Nasal Odorant Transport for the Analysis of Human Olfaction
Keyhani, K., Scherer, P. W., & Mozell, M. M. (1997) · Journal of Theoretical Biology · doi:10.1006/jtbi.1996.0347 · Cited by 191 · cited 2×
“Using Hahn’s experimental measurements for validation, Keyhani et al. (1995, 1997) developed a finite element numerical model of the right side of the human nasal cavity, obtained from the computerized axial tomography (CAT) scans used by Hahn to construct his large physical model and computed…”
Self-citationSpatial patterning of response to odors in the peripheral olfactory system
Moulton, D. G. (1976) · Physiological Reviews · doi:10.1152/physrev.1976.56.3.578 · Cited by 180 · cited 1×
“The spatial odorant deposition pattern on the olfactory mucosa has been postulated by many researchers to be a determinant of olfactory perception (Mozell, 1966, 1970; Numerical Modeling and Odorant Transport during Sniffing 5 Mozell and Jagodowicz, 1973; Moulton, 1976).”
Kimbell, J. S., Gross, E. A., Joyner, D. R., Godo, M. N., & Morgan, K. T. (1993) · Toxicology and Applied Pharmacology · doi:10.1006/taap.1993.1152 · Cited by 176 · cited 2×
“Although CFD has previously been applied to study airflow in the rat nose (Kimbell et al. , 1993, 1997), it was utilized primarily for the purposes of understanding the deposition pattern and nasal toxicity of various chemical agents and not to evaluate the impact of airflow on olfactory perception.”
Strotmann, J. M., Wanner, I. B., Helfrich, T., Beck, A., Meinken, C., Kubick, S., & Breer, H. (1994) · Cell and Tissue Research · doi:10.1007/bf00343941 · Cited by 170 · cited 1×
“These two patterns of odorant absorption correspond roughly to (Strotmann et al. , 1994) zone I (dorsomedial) and zones II and III (lateral) types of receptors, respectively, and imply a structural–functional airflow and odorant detection relationship.”
Mozell, M. M., & Jagodowicz, M. (1973) · Science · doi:10.1126/science.181.4106.1247 · Cited by 157 · cited 1×
“The spatial odorant deposition pattern on the olfactory mucosa has been postulated by many researchers to be a determinant of olfactory perception (Mozell, 1966, 1970; Numerical Modeling and Odorant Transport during Sniffing 5 Mozell and Jagodowicz, 1973; Moulton, 1976).”
Evidence for a Chromatographic Model of Olfaction
Mozell, M. M. (1970) · The Journal of General Physiology · doi:10.1085/jgp.56.1.46 · Cited by 147 · cited 1×
“The spatial odorant deposition pattern on the olfactory mucosa has been postulated by many researchers to be a determinant of olfactory perception (Mozell, 1966, 1970; Numerical Modeling and Odorant Transport during Sniffing 5 Mozell and Jagodowicz, 1973; Moulton, 1976).”
XLI Air Currents in the Upper Respiratory Tract and Their Clinical Importance
Proetz, A. W. (1951) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348945106000216 · Cited by 123 · cited 4×
“The earliest nasal physical models were usually cast from noses of human cadavers (Proetz, 1951; Swift and Proctor, 1977; Girardin et al., 1983; Hornung et al., 1987).”
InfluentialA Numerical Simulation of Intranasal Air Temperature During Inspiration
Lindemann, J., Keck, T., Wiesmiller, K., Sander, B., Brambs, H., Rettinger, G., & Pless, D. (2004) · The Laryngoscope · doi:10.1097/00005537-200406000-00015 · Cited by 110 · cited 1×
“A preliminary simulation of turbulent airflow was carried out by Lindemann et al. (2004) in a recent study, but they did not compare their results to a laminar flow simulation.”
Sniffing Longer rather than Stronger to Maintain Olfactory Detection Threshold
Sobel, N. (2000) · Chemical Senses · doi:10.1093/chemse/25.1.1 · Cited by 104 · cited 2×
“Sobel et al. (2000) has shown that a flow-restricted nostril can achieve a similar perceptual performance (with longer sniff duration) as a high airflow nostril.”
The Spatiotemporal Analysis of Odorants at the Level of the Olfactory Receptor Sheet
Mozell, M. M. (1966) · The Journal of General Physiology · doi:10.1085/jgp.50.1.25 · Cited by 99 · cited 1×
“The spatial odorant deposition pattern on the olfactory mucosa has been postulated by many researchers to be a determinant of olfactory perception (Mozell, 1966, 1970; Numerical Modeling and Odorant Transport during Sniffing 5 Mozell and Jagodowicz, 1973; Moulton, 1976).”
Experimental Study of Velocity Fields in a Human Nasal Fossa by Laser Anemometry
Girardin, M., Bilgen, E., & Arbour, P. (1983) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348948309200304 · Cited by 96 · cited 2×
“The earliest nasal physical models were usually cast from noses of human cadavers (Proetz, 1951; Swift and Proctor, 1977; Girardin et al. , 1983; Hornung et al. , 1987).”
Zhao, K., Pribitkin, E. A., Cowart, B. J., Rosen, D. M., Scherer, P. W., & Dalton, P. (2006) · American Journal of Rhinology · doi:10.2500/ajr.2006.20.2848 · Cited by 87 · cited 1×
“Zhao et al. followed up on Keyhani’s work by developing a rapid meshing procedure starting with CAT scans to compute airflows in the nasal cavities of healthy human subjects (Zhao et al. , 2004) and rhinosinusitis patients, who underwent endoscopic surgery (Zhao et al. , 2006).”
Self-citationKent, P. F., Mozell, M. M., Murphy, S., & Hornung, D. E. (1996) · Journal of Neuroscience · doi:10.1523/jneurosci.16-01-00345.1996 · Cited by 84 · cited 1×
“Kent et al. (1996) employed the voltage-sensitive dye technique to study olfactory mucosal neural activity patterns by puffing three odorants with varying solubility directly onto the entire rat olfactory mucosa and also by drawing the odorants at three different flow rates along the mucosal flow path.”
Airflow Patterns in a Human Nasal Model
Hornung, D. E., Leopold, D. A., Youngentob, S. L., Sheehe, P. R., Gagne, G. M., THOMAS, F. D., & Mozell, M. M. (1987) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.1987.01860020061013 · Cited by 69
Flow Simulation in the Human Upper Respiratory Tract
Martonen, T. B., Quan, L., Zhang, Z., & Musante, C. J. (2002) · Cell Biochemistry and Biophysics · doi:10.1385/cbb:37:1:27 · Cited by 66 · cited 1×
“Martonen et al. (2002) constructed a three-dimensional (3D) physiologically realistic computer model of the human upper respiratory tract that included both nasal cavities.”
Cited by
Odorant Reception in Insects: Roles of Receptors, Binding Proteins, and Degrading Enzymes
Leal, W. S. (2013) · Annual Review of Entomology · doi:10.1146/annurev-ento-120811-153635 · Cited by 1,705
The Sniff Is Part of the Olfactory Percept
Mainland, J., & Sobel, N. (2006) · Chemical Senses · doi:10.1093/chemse/bjj012 · Cited by 392
Sniffing controls an adaptive filter of sensory input to the olfactory bulb
Verhagen, J. V., Wesson, D. W., Netoff, T. I., White, J. A., & Wachowiak, M. (2007) · Nature Neuroscience · doi:10.1038/nn1892 · Cited by 381
All in a Sniff: Olfaction as a Model for Active Sensing
Wachowiak, M. (2011) · Neuron · doi:10.1016/j.neuron.2011.08.030 · Cited by 353
The fluid dynamics of canine olfaction: unique nasal airflow patterns as an explanation of macrosmia
Craven, B. A., Paterson, E. G., & Settles, G. S. (2010) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0490 · Cited by 301
Metadata
- Authors
- Zhao, K., Dalton, P., Yang, G. C., & Scherer, P. W.
- Venue
- Chemical Senses
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-12-14
- Volume
- 31
- Issue
- 2
- Pages
- 107-118
- ISSN
- 0379-864X (ISSN-L)
- 1464-3553
- OpenAlex
- W2169810067
- Cited by
- 189
- References
- 23
- FWCI
- 3.14
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.