CoChat

Evaluation of Glucose-6-Phosphate Dehydrogenase from Leuconostoc mesenteroides in the Hexokinase Method for Determining Glucose in Serum

Bondar, Richard J L, Mead, Donna C · 1974 · Clinical Chemistry
Cited by 357

The DOI matches its Crossref record.

Abstract

The hexokinase (EC 2.7.1.1)/glucose-6-phosphate dehydrogenase (I) (EC 1.1.1.49) method of glucose analysis is highly accurate, precise, and sensitive when I from Leuconostoc mesenteroides and NAD+ are used. Coefficients of variation ranged from 0.68 to 8.9% for glucose standards between 0.56 and 27.7 mmol/liter. Recovery was 103 ± 10% for glucose standards added to sera of known glucose content. Although no substances investigated interfere with the test system when present at their normal or likely concentrations in serum, final reaction mixtures containing mannose (>0.28 mmol/liter), fructose (3.7 mmol/liter), or 2-deoxy-D-glucose (4.01 mmol/liter) inhibit the analysis. With all constituents lyophilized, the reagent mixture is stable for at least a year at 4 °C and for five days at 40 °C. Within-day reproducibility averaged 0.83%; day-to-day precision was 1.3%. We compared results of hexokinase/glucose procedures by using I from yeast (with NADP+) and from L. mesenteroides (with either NAD+ or NADP+ as coenzyme); there was complete correlation over a serum glucose range of 4 to 12 mmol/liter (72 to 217 mg/dl). Use of NAD+ with I from L. mesenteroides is advantageous because of the decreased cost and greater stability of the coenzyme.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/20.5.586

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Bondar, R. J. L., & Mead, D. C.
Venue
Clinical Chemistry
Published
1974-05-01
Volume
20
Issue
5
Pages
586-590
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1955042231
Cited by
357
References
0
FWCI
2.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.