An Overview of Minimally Invasive Technologies
The DOI matches its Crossref record.
Abstract
Self-measurement of blood glucose is an integral part of diabetes mellitus therapy. As many as 65% of diabetic people (4-5 million people) perform some degree of self-monitoring and approximately 20-30% do so frequently. Most patients consider this the most onerous part of their diabetes therapy. It requires obtaining blood, frequently in public, and is usually the most painful part of therapy, being significantly more painful than insulin self-administration. Patients therefore are anxious for a less-invasive method for glucose measurement. Methods exist or are being developed for minimally invasive glucose monitoring, which use body fluids other than blood (e.g., sweat and saliva), subcutaneous tissue, or blood measured less invasively. Sweat and saliva are relatively easily obtained but their glucose concentration lags significantly behind blood glucose. Methods to increase sweating have been developed and seem to increase the timeliness of the sweat glucose measurement. Subcutaneous glucose measurement seems to lag only a few minutes behind blood glucose and may actually be a better measurement of the critical values of glucose concentrations in brain, muscle, and other tissue. Glucose can be measured by noninvasive or minimally invasive methods, such as those making skin or mucous membranes permeable to glucose or those placing a reporter molecule in the subcutaneous tissue. Needle-type sensors have been improved in accuracy, size, and stability and can be placed into the subcutaneous tissue or peripheral veins to monitor blood glucose with miniature instruments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tierney, M. J., Tamada, J. A., Potts, R. O., Jovanovic, L., & Garg, S. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00189-0 · Cited by 390
Spectroscopic and Clinical Aspects of Noninvasive Glucose Measurements
Khalil, O. S. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.2.165 · Cited by 331
Maier, J. S., Walker, S. A., Fantini, S., Franceschini, M. A., & Gratton, E. (1994) · Optics Letters · doi:10.1364/ol.19.002062 · Cited by 318
Noninvasively measuring blood glucose using saliva
Yamaguchi, M., Mitsumori, M., & Kano, Y. (1998) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.677170 · Cited by 129
Overview on self-monitoring of blood glucose
Montagnana, M., Caputo, M., Giavarina, D., & Lippi, G. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.01.002 · Cited by 116
“These techniques have been widely discussed in previous articles [61–66] and, along with telemedicine, they represent the most promising scenario for SMBG.”
MethodSakaguchi, K., Hirota, Y., Hashimoto, N., Ogawa, W., Hamaguchi, T., Matsuo, T., Miyagawa, J.-I., Namba, M., Sato, T., Okada, S., et al. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700313 · Cited by 50
Non-invasive monitoring of gingival crevicular fluid for estimation of blood glucose level
Yamaguchi, M., Kawabata, Y., Kambe, S., W⇘rdell, K., Nystrom, F. H., Naitoh, K., & Yoshida, H. (2004) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344706 · Cited by 36
Metadata
- Authors
- Ginsberg, B. H.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1992-09-01
- Volume
- 38
- Issue
- 9
- Pages
- 1596-1600
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2116652687
- Cited by
- 71
- References
- 0
- FWCI
- 1.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.