The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Microchip systems for immunoassay: an integrated immunoreactor with electrophoretic separation for serum theophylline determination
Abstract
A glass microchip is described in which reagents and serum samples for competitive immunoassay of serum theophylline can be mixed, reacted, separated, and analyzed. The device functions as an automated microfluidic immunoassay system, creating a lab-on-a-chip. Electroosmotic pumping was used to control first the mixing of 50-fold-diluted serum sample with labeled theophylline tracer in a 1:1 ratio, followed by 1:1 mixing and reaction with anti-theophylline antibody. The 51-nL on-chip mixer gave the same concentration as dilution performed off-chip, within 3%. A 100-pL plug of the reacted solution was then injected into an electrophoresis separation channel integrated within the same chip. Measurements of free and bound tracer by fluorescence detection gave linear calibration curves of signal vs log[theophylline] between 0 and 40 mg/L, with a slope of 0.52 ± 0.03 and an intercept of −0.04 ± 0.04 after a 90-s reaction time. A detection limit of 0.26 mg/L in serum (expressed before the dilution step, actual concentration of 1.3 μg/L at the detector) was obtained. Recovery values were 107% ± 8% for 15 mg/L serum samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zone electrophoresis in open-tubular glass capillaries
Jorgenson, J. W., & Lukacs, K. D. (1981) · Analytical Chemistry · doi:10.1021/ac00231a037 · Cited by 2,229
Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip
Harrison, D. J., Fluri, K., Seiler, K., Fan, Z., Effenhauser, C. S., & Manz, A. (1993) · Science · doi:10.1126/science.261.5123.895 · Cited by 1,800
Self-citation(1995) · Springer eBooks · doi:10.1007/978-94-011-0161-5 · Cited by 1,250
Capillary electrophoresis and sample injection systems integrated on a planar glass chip
Harrison, D. J., Manz, A., Fan, Z., Luedi, H., & Widmer, H. M. (1992) · Analytical Chemistry · doi:10.1021/ac00041a030 · Cited by 1,226
Self-citationWoolley, A. T., Hadley, D., Landre, P., deMello, A. J., Mathies, R. A., & Northrup, M. A. (1996) · Analytical Chemistry · doi:10.1021/ac960718q · Cited by 730
Jacobson, S. C., Hergenroder, R., Koutny, L. B., Warmack, R. J., & Ramsey, J. M. (1994) · Analytical Chemistry · doi:10.1021/ac00079a028 · Cited by 669
Effenhauser, C. S., Bruin, G. J. M., Paulus, A., & Ehrat, M. (1997) · Analytical Chemistry · doi:10.1021/ac9703919 · Cited by 640
Handbook of Biochemistry. Selected Data for Molecular Biology.
(1969) · Annals of Internal Medicine · doi:10.7326/0003-4819-70-1-239 · Cited by 559
Transport, Manipulation, and Reaction of Biological Cells On-Chip Using Electrokinetic Effects
Li, P. C. H., & Harrison, D. J. (1997) · Analytical Chemistry · doi:10.1021/ac9606564 · Cited by 422
Self-citationChiem, N., & Harrison, D. J. (1997) · Analytical Chemistry · doi:10.1021/ac9606620 · Cited by 397
Self-citationMicrochip Electrophoretic Immunoassay for Serum Cortisol
Koutny, L. B., Schmalzing, D., Taylor, T. A., & Fuchs, M. (1996) · Analytical Chemistry · doi:10.1021/ac9508311 · Cited by 315
Manz, A., Fettinger, J. C., Verpoorte, E., Lüdi, H., Widmer, H. M., & Harrison, D. J. (1991) · TrAC Trends in Analytical Chemistry · doi:10.1016/0165-9936(91)85116-9 · Cited by 228
Self-citationPrototype miniature blood gas analyser fabricated on a silicon wafer
Shoji, S., Esashi, M., & Matsuo, T. (1988) · Sensors and Actuators · doi:10.1016/0250-6874(88)80057-x · Cited by 124
Cited by
Soft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,607
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
Microfluidic devices fabricated in Poly(dimethylsiloxane) for biological studies
Sia, S. K., & Whitesides, G. M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305584 · Cited by 1,717
Point-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
Johnson, T. J., Ross, D., & Locascio, L. E. (2002) · Analytical Chemistry · doi:10.1021/ac010895d · Cited by 547
Metadata
- Authors
- Chiem, N. H., & Harrison, D. J.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-03-01
- Volume
- 44
- Issue
- 3
- Pages
- 591-598
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1829459140
- Cited by
- 264
- References
- 13
- FWCI
- 31.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.