Microchip systems for immunoassay: an integrated immunoreactor with electrophoretic separation for serum theophylline determination
Abstract
A glass microchip is described in which reagents and serum samples for competitive immunoassay of serum theophylline can be mixed, reacted, separated, and analyzed. The device functions as an automated microfluidic immunoassay system, creating a lab-on-a-chip. Electroosmotic pumping was used to control first the mixing of 50-fold-diluted serum sample with labeled theophylline tracer in a 1:1 ratio, followed by 1:1 mixing and reaction with anti-theophylline antibody. The 51-nL on-chip mixer gave the same concentration as dilution performed off-chip, within 3%. A 100-pL plug of the reacted solution was then injected into an electrophoresis separation channel integrated within the same chip. Measurements of free and bound tracer by fluorescence detection gave linear calibration curves of signal vs log[theophylline] between 0 and 40 mg/L, with a slope of 0.52 ± 0.03 and an intercept of −0.04 ± 0.04 after a 90-s reaction time. A detection limit of 0.26 mg/L in serum (expressed before the dilution step, actual concentration of 1.3 μg/L at the detector) was obtained. Recovery values were 107% ± 8% for 15 mg/L serum samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zone electrophoresis in open-tubular glass capillaries
Jorgenson, J. W., & Lukacs, K. D. (1981) · Analytical Chemistry · doi:10.1021/ac00231a037 · Cited by 2,229
Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip
Harrison, D. J., Fluri, K., Seiler, K., Fan, Z., Effenhauser, C. S., & Manz, A. (1993) · Science · doi:10.1126/science.261.5123.895 · Cited by 1,800
Self-citation(1995) · Springer eBooks · doi:10.1007/978-94-011-0161-5 · Cited by 1,250
Capillary electrophoresis and sample injection systems integrated on a planar glass chip
Harrison, D. J., Manz, A., Fan, Z., Luedi, H., & Widmer, H. M. (1992) · Analytical Chemistry · doi:10.1021/ac00041a030 · Cited by 1,226
Self-citationWoolley, A. T., Hadley, D., Landre, P., deMello, A. J., Mathies, R. A., & Northrup, M. A. (1996) · Analytical Chemistry · doi:10.1021/ac960718q · Cited by 730
Jacobson, S. C., Hergenroder, R., Koutny, L. B., Warmack, R. J., & Ramsey, J. M. (1994) · Analytical Chemistry · doi:10.1021/ac00079a028 · Cited by 669
Effenhauser, C. S., Bruin, G. J. M., Paulus, A., & Ehrat, M. (1997) · Analytical Chemistry · doi:10.1021/ac9703919 · Cited by 640
Handbook of Biochemistry. Selected Data for Molecular Biology.
(1969) · Annals of Internal Medicine · doi:10.7326/0003-4819-70-1-239 · Cited by 559
Transport, Manipulation, and Reaction of Biological Cells On-Chip Using Electrokinetic Effects
Li, P. C. H., & Harrison, D. J. (1997) · Analytical Chemistry · doi:10.1021/ac9606564 · Cited by 422
Self-citationChiem, N., & Harrison, D. J. (1997) · Analytical Chemistry · doi:10.1021/ac9606620 · Cited by 397
Self-citation
Cited by
Soft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,607
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
Microfluidic devices fabricated in Poly(dimethylsiloxane) for biological studies
Sia, S. K., & Whitesides, G. M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305584 · Cited by 1,717
Point-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
Johnson, T. J., Ross, D., & Locascio, L. E. (2002) · Analytical Chemistry · doi:10.1021/ac010895d · Cited by 547
Microfluidic chips for clinical and forensic analysis
Verpoorte, E. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200203)23:5<677::aid-elps677>3.0.co;2-8 · Cited by 526
Lab-on-a-chip for drug development
Weigl, B. H., Bardell, R. L., & Cabrera, C. R. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(02)00223-5 · Cited by 481
High-throughput and ultra-high-throughput screening: solution- and cell-based approaches
Sundberg, S. (2000) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(99)00051-8 · Cited by 455
Molecular profiling of human cancer
Liotta, L., & Petricoin, E. (2000) · Nature Reviews Genetics · doi:10.1038/35049567 · Cited by 446
Design of a Compact Disk-like Microfluidic Platform for Enzyme-Linked Immunosorbent Assay
Lai, S., Wang, S., Luo, J., Lee, L. J., Yang, S.-T., & Madou, M. J. (2004) · Analytical Chemistry · doi:10.1021/ac0348322 · Cited by 418
A rapid diffusion immunoassay in a T-sensor
Hatch, A., Kamholz, A. E., Hawkins, K. R., Munson, M. S., Schilling, E. A., Weigl, B. H., & Yager, P. (2001) · Nature Biotechnology · doi:10.1038/88135 · Cited by 383
Immunoassays in microfluidic systems
Ng, A. H. C., Uddayasankar, U., & Wheeler, A. R. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3678-8 · Cited by 345
Yakovleva, J., Davidsson, R., Lobanova, A., Bengtsson, M., Eremin, S., Laurell, T., & Emnéus, J. (2002) · Analytical Chemistry · doi:10.1021/ac015645b · Cited by 330
Handbook of Affinity Chromatography
(2005) · CRC Press eBooks · doi:10.1201/9780824751982 · Cited by 310
Bousse, L., Mouradian, S., Minalla, A., Yee, H., Williams, K., & Dubrow, R. (2001) · Analytical Chemistry · doi:10.1021/ac0012492 · Cited by 283
Microfluidic systems in proteomics
Lion, N., Rohner, T. C., Dayon, L., Arnaud, I. L., Damoc, E., Youhnovski, N., Wu, Z., Roussel, C., Josserand, J., Jensen, H., et al. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305629 · Cited by 262
Metadata
- Authors
- Chiem, N. H., & Harrison, D. J.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-03-01
- Volume
- 44
- Issue
- 3
- Pages
- 591-598
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W1829459140
- Cited by
- 264
- References
- 13
- FWCI
- 31.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.