Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 235

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Noninvasive Prediction of Glucose by Near-Infrared Diffuse Reflectance Spectroscopy

Open access
Malin, Stephen F, Ruchti, Timothy L, Blank, Thomas B, Thennadil, Suresh N, Monfre, Stephen L·1999·Clinical Chemistry

Abstract

Background: Self-monitoring of blood glucose by diabetics is crucial in the reduction of complications related to diabetes. Current monitoring techniques are invasive and painful, and discourage regular use. The aim of this study was to demonstrate the use of near-infrared (NIR) diffuse reflectance over the 1050–2450 nm wavelength range for noninvasive monitoring of blood glucose. Methods: Two approaches were used to develop calibration models for predicting the concentration of blood glucose. In the first approach, seven diabetic subjects were studied over a 35-day period with random collection of NIR spectra. Corresponding blood samples were collected for analyte analysis during the collection of each NIR spectrum. The second approach involved three nondiabetic subjects and the use of oral glucose tolerance tests (OGTTs) over multiple days to cause fluctuations in blood glucose concentrations. Twenty NIR spectra were collected over the 3.5-h test, with 16 corresponding blood specimens taken for analyte analysis. Results: Statistically valid calibration models were developed on three of the seven diabetic subjects. The mean standard error of prediction through cross-validation was 1.41 mmol/L (25 mg/dL). The results from the OGTT testing of three nondiabetic subjects yielded a mean standard error of calibration of 1.1 mmol/L (20 mg/dL). Validation of the calibration model with an independent test set produced a mean standard error of prediction equivalent to 1.03 mmol/L (19 mg/dL). Conclusions: These data provide preliminary evidence and allow cautious optimism that NIR diffuse reflectance spectroscopy using the 1050–2450 nm wavelength range can be used to predict blood glucose concentrations noninvasively. Substantial research is still required to validate whether this technology is a viable tool for long-term home diagnostic use by diabetics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/45.9.1651

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Research works printed but not linked: 19

  1. 1992, Clin Chem, 38, 1618, 10.1093/clinchem/38.9.1618 · DOI · Paper page
  2. 1992, Appl Spectrosc, 46, 959, 10.1366/0003702924124493 · doi:10.1366/0003702924124493
  3. 1994, Artif Org, 18, 439, 10.1111/j.1525-1594.1994.tb02230.x · DOI
  4. 1993, Appl Spectrosc, 47, 875, 10.1366/0003702934415354 · DOI · Paper page
  5. 1994, SPIE Proc, 2089, 114, 10.1117/12.166662 · doi:10.1117/12.166662
  6. 1995, Z Phys Chem, 191S, 179
  7. 1997, Fresenius J Anal Chem, 359, 78, 10.1007/s002160050539 · doi:10.1007/s002160050539
  8. 1998, LEOS Newslett, 12, 9
  9. 1997, Int J Artif Organs, 20, 285, 10.1177/039139889702000509 · DOI
  10. 1995, Appl Optics, 34, 610, 10.1364/AO.34.000610 · DOI
  11. 1999, Clin Chem, 45, 165, 10.1093/clinchem/45.2.165 · DOI · Paper page
  12. 1990, Anal Chem, 62, 1457, 10.1021/ac00213a021 · DOI
  13. 1996, Anal Chem, 68, 1124, 10.1021/ac950751x · DOI
  14. 1998, Anal Chem, 70, 1773, 10.1021/ac9710801 · DOI
  15. 1986, Anal Chim Acta, 185, 1, 10.1016/0003-2670(86)80028-9 · DOI · Paper page
  16. 1985, Appl Spectrosc, 39, 491, 10.1366/0003702854248656 · DOI · Paper page
  17. 1981, J Investig Dermatol, 77, 13, 10.1111/1523-1747.ep12479191 · DOI · Paper page
  18. 1989, IEEE Trans Biomed Eng, 36, 1146, 10.1109/10.42108 · DOI · Paper page
  19. 1993, J Soc Cosmet Chem, 44, 249

Cited by

See all 235

Metadata

Authors
Malin, S. F., Ruchti, T. L., Blank, T. B., Thennadil, S. N., & Monfre, S. L.
Venue
Clinical Chemistry
Published
1999-09-01
Volume
45
Issue
9
Pages
1651-1658
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2120439062
Cited by
235
References
2
FWCI
2.73
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Noninvasive Prediction of Glucose by Near-Infrared Diffuse Reflectance Spectroscopy. https://app.cochat.ai/papers/10.1093/clinchem/45.9.1651
The paper
Malin, S. F., Ruchti, T. L., Blank, T. B., Thennadil, S. N., & Monfre, S. L. (1999). Noninvasive Prediction of Glucose by Near-Infrared Diffuse Reflectance Spectroscopy. Clinical Chemistry. https://doi.org/10.1093/clinchem/45.9.1651

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.