Noninvasive Prediction of Glucose by Near-Infrared Diffuse Reflectance Spectroscopy
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Background: Self-monitoring of blood glucose by diabetics is crucial in the reduction of complications related to diabetes. Current monitoring techniques are invasive and painful, and discourage regular use. The aim of this study was to demonstrate the use of near-infrared (NIR) diffuse reflectance over the 1050–2450 nm wavelength range for noninvasive monitoring of blood glucose. Methods: Two approaches were used to develop calibration models for predicting the concentration of blood glucose. In the first approach, seven diabetic subjects were studied over a 35-day period with random collection of NIR spectra. Corresponding blood samples were collected for analyte analysis during the collection of each NIR spectrum. The second approach involved three nondiabetic subjects and the use of oral glucose tolerance tests (OGTTs) over multiple days to cause fluctuations in blood glucose concentrations. Twenty NIR spectra were collected over the 3.5-h test, with 16 corresponding blood specimens taken for analyte analysis. Results: Statistically valid calibration models were developed on three of the seven diabetic subjects. The mean standard error of prediction through cross-validation was 1.41 mmol/L (25 mg/dL). The results from the OGTT testing of three nondiabetic subjects yielded a mean standard error of calibration of 1.1 mmol/L (20 mg/dL). Validation of the calibration model with an independent test set produced a mean standard error of prediction equivalent to 1.03 mmol/L (19 mg/dL). Conclusions: These data provide preliminary evidence and allow cautious optimism that NIR diffuse reflectance spectroscopy using the 1050–2450 nm wavelength range can be used to predict blood glucose concentrations noninvasively. Substantial research is still required to validate whether this technology is a viable tool for long-term home diagnostic use by diabetics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Smoothing and Differentiation of Data by Simplified Least Squares Procedures.
Savitzky, A., & Golay, M. J. E. (1964) · Analytical Chemistry · doi:10.1021/ac60214a047 · Cited by 21,904
Partial least-squares regression: a tutorial
Geladi, P., & Kowalski, B. R. (1986) · Analytica Chimica Acta · doi:10.1016/0003-2670(86)80028-9 · Cited by 6,992 · cited 1×
“Calibration models were developed through PLS regression ( 19 ). Model performance is reported as the standard error of calibration (SEC) and SEP corresponding to the root mean square error of the glucose predictions over the calibration and test sets, respectively.”
MethodA review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Anderson, R. R., & Parrish, J. A. (1981) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12479191 · Cited by 2,456
Linearization and Scatter-Correction for Near-Infrared Reflectance Spectra of Meat
Geladi, P., MacDougall, D., & Martens, H. (1985) · Applied Spectroscopy · doi:10.1366/0003702854248656 · Cited by 1,513 · cited 1×
“single-subject studies Spectra collected on each subject were converted to absorbance units and preprocessed via multiplicative scatter correction ( 20 ) and Savisky-Golay 55-point smoothing (21 ). Calibration models were developed through PLS using the wavelength ranges 1100 ‐1380, 1450 ‐1850, and 2050 ‐2375 nm. Howe…”
MethodMassart, D. L. (1988) · Cited by 1,347
Van Gemert, M. J. C., Jacques, S. L., Sterenborg, H. J. C. M., & Star, W. M. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.42108 · Cited by 807
Spectroscopic and Clinical Aspects of Noninvasive Glucose Measurements
Khalil, O. S. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.2.165 · Cited by 331 · cited 1×
“Additionally, accurate noninvasive estimation of blood glucose is limited at present by the available NIR technology and the dynamic nature of the sample: the skin and living tissue of the patient [for example, see Khalil ( 14 )]. Chemical, structural, and physiological variations occur that produce dramatic and nonli…”
BackgroundNoninvasive Glucose Monitoring in Diabetic Patients: A Preliminary Evaluation
Robinson, M. R., Eaton, R. P., Haaland, D. M., Koepp, G. W., Thomas, E. V., Stallard, B. R., & Robinson, P. L. (1992) · Clinical Chemistry · doi:10.1093/clinchem/38.9.1618 · Cited by 284
Research works printed but not linked: 6
- 1992, Appl Spectrosc, 46, 959, 10.1366/0003702924124493 · doi:10.1366/0003702924124493
- 1994, SPIE Proc, 2089, 114, 10.1117/12.166662 · doi:10.1117/12.166662
- 1995, Z Phys Chem, 191S, 179
- 1997, Fresenius J Anal Chem, 359, 78, 10.1007/s002160050539 · doi:10.1007/s002160050539
- 1998, LEOS Newslett, 12, 9
- 1993, J Soc Cosmet Chem, 44, 249
Cited by
NIR spectroscopy: a rapid-response analytical tool
Blanco, M., & Villarroya, I. (2002) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(02)00404-1 · Cited by 874
Non-invasive glucose monitoring technology in diabetes management: A review
Vashist, S. K. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.03.043 · Cited by 575
Prospects and limitations of non-invasive blood glucose monitoring using near-infrared spectroscopy
Yadav, J., Rani, A., Singh, V., & Murari, B. M. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.01.005 · Cited by 374
Advances in cost-effective integrated spectrometers
Li, A., Yao, C., Xia, J., Wang, H., Cheng, Q., Penty, R., Fainman, Y., & Pan, S. (2022) · Light: Science & Applications · doi:10.1038/s41377-022-00853-1 · Cited by 309
Sensors for glucose monitoring: technical and clinical aspects
Koschinsky, T., & Heinemann, L. (2001) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.188 · Cited by 288
Tura, A., Maran, A., & Pacini, G. (2007) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2006.10.027 · Cited by 283
“Notes Definitions of NIR band are not always in agreement: some authors define NIR in the 750–2500 nm band [9], others in 1000–2500 nm band, whereas they define the 700–1000 nm band as the infrared band [10].”
BackgroundRecent developments in nanostructure based electrochemical glucose sensors
Zaidi, S. A., & Shin, J. H. (2016) · Talanta · doi:10.1016/j.talanta.2015.11.033 · Cited by 281
Non-Invasive Glucose Measurement Technologies: An Update from 1999 to the Dawn of the New Millennium
Khalil, O. S. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2004.6.660 · Cited by 255
Pullano, S. A., Greco, M., Bianco, M. G., Foti, D., Brunetti, A., & Fiorillo, A. S. (2022) · Theranostics · doi:10.7150/thno.64035 · Cited by 210
Tear glucose analysis for the noninvasive detection and monitoring of diabetes mellitus
Baca, J. T., Finegold, D. N., & Asher, S. A. (2007) · The Ocular Surface · doi:10.1016/s1542-0124(12)70094-0 · Cited by 187
Thennadil, S. N., Rennert, J. L., Wenzel, B. J., Hazen, K. H., Ruchti, T. L., & Block, M. B. (2001) · Diabetes Technology & Therapeutics · doi:10.1089/15209150152607132 · Cited by 166
Self-citation
Metadata
- Authors
- Malin, S. F., Ruchti, T. L., Blank, T. B., Thennadil, S. N., & Monfre, S. L.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-09-01
- Volume
- 45
- Issue
- 9
- Pages
- 1651-1658
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2120439062
- Cited by
- 235
- References
- 19
- FWCI
- 2.73
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.