Non-invasive assessment of the age related changes in stiffness of major branches of the human arteries
The DOI matches its Crossref record.
Abstract
The static mechanical properties of major branches of the human arteries (common carotid artery, abdominal aorta, femoral artery, and brachial artery) were studied in 39 subjects, aged 6-81 years, using an ultrasonic phase locked echo tracking system that allows continuous transcutaneous measurement of the diameter of the artery. The stiffness indices were calculated from the relation between systemic blood pressure and arterial diameter. With advancing age there was a significant increase in the diameter of all arteries with a reduction in percentage change in diameter. The stiffness index increased with age in all arteries; however, in the brachial and femoral arteries there was considerable variation in the individual values for a given age. The age associated increase in stiffness was statistically significant only in the common carotid artery and the abdominal aorta. Although the mechanical properties of the peripheral arteries were significantly influenced by the measuring environment, the calculated stiffness indices were less vulnerable to these stimuli in the central arteries. These results indicate that the stiffness indices of the peripheral muscular arteries are modified appreciably by vasoactive stimuli and that the mechanical properties of the deeper elastic arteries provide sufficiently reliable information about changes caused by aging and arteriosclerosis. The new ultrasonic method used appears to be suitable for this analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Is Pulse Pressure Useful in Predicting Risk for Coronary Heart Disease?: The Framingham Heart Study
Franklin, S. S., Khan, S. A., Wong, N. D., Larson, M. G., & Levy, D. (1999) · Circulation · doi:10.1161/01.cir.100.4.354 · Cited by 1,759
Clinical applications of arterial stiffness; definitions and reference values
O'Rourke, M. F., Staessen, J. A., Vlachopoulos, C., Duprez, D., & Plante, G. E. E. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(01)02319-6 · Cited by 1,100
Ageing of the conduit arteries
Greenwald, S. (2007) · The Journal of Pathology · doi:10.1002/path.2101 · Cited by 637
Benetos, A., Laurent, S., Hoeks, A. P., Boutouyrie, P. H., & Safar, M. E. (1993) · Arteriosclerosis and Thrombosis: A Journal of Vascular Biology · doi:10.1161/01.atv.13.1.90 · Cited by 587
Salomaa, V., Riley, W., Kark, J. D., Nardo, C., & Folsom, A. R. (1995) · Circulation · doi:10.1161/01.cir.91.5.1432 · Cited by 582
Noninvasive Pulse Wave Analysis for the Early Detection of Vascular Disease
Cohn, J. N., Finkelstein, S., McVeigh, G., Morgan, D., LeMay, L., Robinson, J., & Mock, J. (1995) · Hypertension · doi:10.1161/01.hyp.26.3.503 · Cited by 474
Shirai, K., Hiruta, N., Song, M., Kurosu, T., Suzuki, J., Tomaru, T., Miyashita, Y., Saiki, A., Takahashi, M., Suzuki, K., et al. (2011) · Journal of Atherosclerosis and Thrombosis · doi:10.5551/jat.7716 · Cited by 458
Metabolic syndrome amplifies the age-associated increases in vascular thickness and stiffness
Scuteri, A., Najjar, S. S., Muller, D. C., Andres, R., Hougaku, H., Metter, E. J., & Lakatta, E. G. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.10.061 · Cited by 447
Chen, C.-H., Ting, C.-T., Nussbacher, A., Nevo, E., Kass, D. A., Pak, P., Wang, S.-P., Chang, M.-S., & Yin, F. C. P. (1996) · Hypertension · doi:10.1161/01.hyp.27.2.168 · Cited by 401
Gan, C. T.-J., Lankhaar, J.-W., Westerhof, N., Marcus, J. T., Becker, A., Twisk, J. W. R., Boonstra, A., Postmus, P. E., & Vonk-Noordegraaf, A. (2007) · Chest · doi:10.1378/chest.07-1246 · Cited by 394
van der Heijden-Spek, J. J., Staessen, J. A., Fagard, R. H., Hoeks, A. P., Boudier, H. A. S., & Van Bortel, L. M. (2000) · Hypertension · doi:10.1161/01.hyp.35.2.637 · Cited by 388
Parallel cardiac and vascular adaptation in hypertension.
Roman, M. J., Saba, P. S., Pini, R., Spitzer, M., Pickering, T. G., Rosen, S., Alderman, M. H., & Devereux, R. B. (1992) · Circulation · doi:10.1161/01.cir.86.6.1909 · Cited by 365
Fatigue and durability of Nitinol stents
Pelton, A. R., Schroeder, V., Mitchell, M. R., Gong, X.-Y., Barney, M., & Robertson, S. W. (2008) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2007.08.001 · Cited by 365
Simons, P. C. G., Algra, A., Bots, M. L., Grobbee, D. E., & van der Graaf, Y. (1999) · Circulation · doi:10.1161/01.cir.100.9.951 · Cited by 349
Jourdan, C., Wühl, E., Litwin, M., Fahr, K., Trelewicz, J., Jobs, K., Schenk, J.-P., Grenda, R., Mehls, O., Tröger, J., et al. (2005) · Journal of Hypertension · doi:10.1097/01.hjh.0000178834.26353.d5 · Cited by 347
Methods and devices for measuring arterial compliance in humans
Pannier, B. M., Avolio, A. P., Hoeks, A., Mancia, G., & Takazawa, K. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(02)02962-x · Cited by 343
Determinants of Echocardiographic Aortic Root Size: The Framingham Heart Study
Vasan, R. S., Larson, M. G., & Levy, D. (1995) · Circulation · doi:10.1161/01.cir.91.3.734 · Cited by 315
Kumeda, Y., Inaba, M., Goto, H., Nagata, M., Henmi, Y., Furumitsu, Y., Ishimura, E., Inui, K., Yutani, Y., Miki, T., et al. (2002) · Arthritis & Rheumatism · doi:10.1002/art.10269 · Cited by 313
Dernellis, J., & Panaretou, M. (2005) · Hypertension · doi:10.1161/01.hyp.0000157818.58878.93 · Cited by 306
Martin, H., Hu, J., Gennser, G., & Norman, M. (2000) · Circulation · doi:10.1161/01.cir.102.22.2739 · Cited by 295
Diameter and compliance in the human common carotid artery — variations with age and sex
Hansen, F., Mangell, P., Sonesson, B., & Länne, T. (1995) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(94)00090-5 · Cited by 293
Sex differences in mechanisms of arterial stiffness
DuPont, J. J., Kenney, R. M., Patel, A. R., & Jaffe, I. Z. (2019) · British Journal of Pharmacology · doi:10.1111/bph.14624 · Cited by 290
Olprinone: A Phosphodiesterase III Inhibitor with Positive Inotropic and Vasodilator Effects
Mizushige, K., Ueda, T., Yukiiri, K., & Suzuki, H. (2002) · Cardiovascular Drug Reviews · doi:10.1111/j.1527-3466.2002.tb00085.x · Cited by 285
Physiological Diagnostic Criteria for Vascular Failure
Tanaka, A., Tomiyama, H., Maruhashi, T., Matsuzawa, Y., Miyoshi, T., Kabutoya, T., Kario, K., Sugiyama, S., Munakata, M., Ito, H., et al. (2018) · Hypertension · doi:10.1161/hypertensionaha.118.11554 · Cited by 280
AGE, HYPERTENSION AND ARTERIAL FUNCTION
McEniery, C. M., Wilkinson, I. B., & Avolio, A. P. (2007) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/j.1440-1681.2007.04657.x · Cited by 267
Compliance properties of conduits used in vascular reconstruction
Tai, N. R., Salacinski, H. J., Edwards, A., Hamilton, G., & Seifalian, A. M. (2000) · Journal of British Surgery · doi:10.1046/j.1365-2168.2000.01566.x · Cited by 267
Saba, P. S., Roman, M. J., Pini, R., Spitzer, M., Ganau, A., & Devereux, R. B. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90772-s · Cited by 266
Dart, A. M., Lacombe, F., Yeoh, J. K., Cameron, J. D., Jennings, G. L., Laufer, E., & Esmore, D. S. (1991) · The Lancet · doi:10.1016/0140-6736(91)90415-l · Cited by 261
Compliance and diameter in the human abdominal aorta—The influence of age and sex
Sonesson, B., Hansen, F., Stale, H., & Länne, T. (1993) · European Journal of Vascular Surgery · doi:10.1016/s0950-821x(05)80718-2 · Cited by 252
Fleenor, B. S., Marshall, K. D., Durrant, J. R., Lesniewski, L. A., & Seals, D. R. (2010) · The Journal of Physiology · doi:10.1113/jphysiol.2010.194753 · Cited by 212
“As is the case in humans (Kawasaki et al. 1987; Tanaka et al. 1998), the B6D2F1 mouse demonstrates stiffening of the carotid artery with ageing in the absence of increases in peripheral artery stiffness (Lesniewski et al. 2009).”
BackgroundAortic root disease and valve disease associated with ankylosing spondylitis
Roldan, C. A., Chavez, J., Wiest, P. W., Qualls, C. R., & Crawford, M. H. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00393-3 · Cited by 198
“From four to six blood pressure measurements during TEE and the root diameters, aortic elasticity at the sinuses and tubular portions were calculated by the Peterson’s pressure– strain elastic modulus as 10(6) dynes cm(22) and the pressureindependent stiffness index (B) (18,19).”
MethodDiameter and compliance in the male human abdominal aorta: Influence of age and aortic aneurysm
Länne, T., Sonesson, B., Bergqvist, D., Bengtsson, H., & Gustafsson, D. (1992) · European Journal of Vascular Surgery · doi:10.1016/s0950-821x(05)80237-3 · Cited by 197
Shirai, K., Song, M., Suzuki, J., Kurosu, T., Oyama, T., Nagayama, D., Miyashita, Y., Yamamura, S., & Takahashi, M. (2011) · Journal of Atherosclerosis and Thrombosis · doi:10.5551/jat.3582 · Cited by 195
Wall shear stress in the human common carotid artery as function of age and gender
Samijo, S. K., Willigers, J. M., Barkhuysen, R., Kitslaar, P. J. E. H. M., Reneman, R. S., Brands, P. J., & Hoeks, A. P. G. (1998) · Cardiovascular Research · doi:10.1016/s0008-6363(98)00074-1 · Cited by 190
Khamdaeng, T., Luo, J., Vappou, J., Terdtoon, P., & Konofagou, E. E. (2012) · Ultrasonics · doi:10.1016/j.ultras.2011.09.006 · Cited by 156
Genesis of the normal and abnormal arterial pulse
Vlachopoulos, C., & O'Rourke, M. (2000) · Current Problems in Cardiology · doi:10.1067/mcd.2000.104057 · Cited by 125
Dernellis, J., & Panaretou, M. (2002) · American Heart Journal · doi:10.1067/mhj.2002.120766 · Cited by 115
Blache, D., Devaux, S., Joubert, O., Loreau, N., Schneider, M., Durand, P., Prost, M., Gaume, V., Adrian, M., Laurant, P., et al. (2006) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2006.04.008 · Cited by 105
Theoretical study on the effect of sensor contact force on pulse transit time
Teng, X.-F., & Zhang, Y.-T. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.900815 · Cited by 94
Metadata
- Authors
- KAWASAKI, T., SASAYAMA, S., YAGI, S.-I., ASAKAWA, T., & HIRAI, T.
- Venue
- Cardiovascular Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1987-09-01
- Volume
- 21
- Issue
- 9
- Pages
- 678-687
- ISSN
- 0008-6363 (ISSN-L)
- OpenAlex
- W2014231512
- Cited by
- 655
- References
- 0
- FWCI
- 0.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.