Application of artificial intelligence to the electrocardiogram
Open accessThe DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
Artificial intelligence (AI) has given the electrocardiogram (ECG) and clinicians reading them super-human diagnostic abilities. Trained without hard-coded rules by finding often subclinical patterns in huge datasets, AI transforms the ECG, a ubiquitous, non-invasive cardiac test that is integrated into practice workflows, into a screening tool and predictor of cardiac and non-cardiac diseases, often in asymptomatic individuals. This review describes the mathematical background behind supervised AI algorithms, and discusses selected AI ECG cardiac screening algorithms including those for the detection of left ventricular dysfunction, episodic atrial fibrillation from a tracing recorded during normal sinus rhythm, and other structural and valvular diseases. The ability to learn from big data sets, without the need to understand the biological mechanism, has created opportunities for detecting non-cardiac diseases as COVID-19 and introduced challenges with regards to data privacy. Like all medical tests, the AI ECG must be carefully vetted and validated in real-world clinical environments. Finally, with mobile form factors that allow acquisition of medical-grade ECGs from smartphones and wearables, the use of AI may enable massive scalability to democratize healthcare.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Grad-CAM: Visual Explanations from Deep Networks via Gradient-Based Localization
Selvaraju, R. R., Cogswell, M., Das, A., Vedantam, R., Parikh, D., & Batra, D. (2017) · 2017 IEEE International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2017.74 · Cited by 24,513
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström-Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P. E., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 9,971
Survey on deep learning with class imbalance
Johnson, J. M., & Khoshgoftaar, T. M. (2019) · Journal of Big Data · doi:10.1186/s40537-019-0192-5 · Cited by 3,032
Cryptogenic stroke and underlying atrial fibrillation
Sanna, T., Diener, H.-C., Passman, R. S., Di Lazzaro, V., Bernstein, R. A., Morillo, C. A., Rymer, M. M., Thijs, V., Rogers, T., Beckers, F., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1313600 · Cited by 2,161 · cited 2×
“14,38 In patients with embolic stroke of uncertain source, the choice of anti-platelet vs. anticoagulant therapy depends on the absence or presence of AF.”
Attia, Z. I., Noseworthy, P. A., Lopez-Jimenez, F., Asirvatham, S. J., Deshmukh, A. J., Gersh, B. J., Carter, R. E., Yao, X., Rabinstein, A. A., Erickson, B. J., et al. (2019) · The Lancet · doi:10.1016/s0140-6736(19)31721-0 · Cited by 1,613 · cited 2×
“2,3,13,14 17 The ECG is a rapid, cost-effective, point-of-care test that requires no blood and no reagents, that is massively scalable with smartphone technology to medical and non-medical environments.”
Self-citationAttia, Z. I., Kapa, S., Lopez-Jimenez, F., McKie, P. M., Ladewig, D. J., Satam, G., Pellikka, P. A., Enriquez-Sarano, M., Noseworthy, P. A., Munger, T. M., et al. (2019) · Nature Medicine · doi:10.1038/s41591-018-0240-2 · Cited by 1,389 · cited 3×
“2,3,13,14 17 The ECG is a rapid, cost-effective, point-of-care test that requires no blood and no reagents, that is massively scalable with smartphone technology to medical and non-medical environments.”
Self-citationArtificial intelligence-enhanced electrocardiography in cardiovascular disease management
Siontis, K. C., Noseworthy, P. A., Attia, Z. I., & Friedman, P. A. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-00503-2 · Cited by 914
Self-citationPassive Detection of Atrial Fibrillation Using a Commercially Available Smartwatch
Tison, G. H., Sanchez, J. M., Ballinger, B., Singh, A., Olgin, J. E., Pletcher, M. J., Vittinghoff, E., Lee, E. S., Fan, S. M., Gladstone, R. A., et al. (2018) · JAMA Cardiology · doi:10.1001/jamacardio.2018.0136 · Cited by 566
Electrocardiographic interpretation in athletes: the ‘Seattle Criteria’
Drezner, J. A., Ackerman, M. J., Anderson, J., Ashley, E., Asplund, C. A., Baggish, A. L., Börjesson, M., Cannon, B. C., Corrado, D., DiFiori, J. P., et al. (2013) · British Journal of Sports Medicine · doi:10.1136/bjsports-2012-092067 · Cited by 550
Early Surgery or Conservative Care for Asymptomatic Aortic Stenosis
Kang, D.-H., Park, S.-J., Lee, S.-A., Lee, S., Kim, D.-H., Kim, H.-K., Yun, S.-C., Hong, G.-R., Song, J.-M., Chung, C.-H., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa1912846 · Cited by 537 · cited 1×
“48 Current screening methods rely on expert examination and auscultation that prompt echocardiography.”
Cited by
Artificial intelligence in clinical medicine: catalyzing a sustainable global healthcare paradigm
Krishnan, G., Singh, S., Pathania, M., Gosavi, S., Abhishek, S., Parchani, A., & Dhar, M. (2023) · Frontiers in Artificial Intelligence · doi:10.3389/frai.2023.1227091 · Cited by 296
Prospective evaluation of smartwatch-enabled detection of left ventricular dysfunction
Attia, Z. I., Harmon, D. M., Dugan, J., Manka, L., Lopez-Jimenez, F., Lerman, A., Siontis, K. C., Noseworthy, P. A., Yao, X., Klavetter, E. W., et al. (2022) · Nature Medicine · doi:10.1038/s41591-022-02053-1 · Cited by 154
Self-citationLin, C.-S., Liu, W.-T., Tsai, D.-J., Lou, Y.-S., Chang, C.-H., Lee, C.-C., Fang, W.-H., Wang, C.-C., Chen, Y.-Y., Lin, W.-S., et al. (2024) · Nature Medicine · doi:10.1038/s41591-024-02961-4 · Cited by 115
“Physicians may order additional tests based on previous evidence that the AI-ECG identified subtle changes in underlying cardiac diseases 34 , particularly low EF 17 and paroxysmal atrial fibrillation 18 .”
A systematic review of intermediate fusion in multimodal deep learning for biomedical applications
Guarrasi, V., Aksu, F., Caruso, C. M., Di Feola, F., Rofena, A., Ruffini, F., & Soda, P. (2025) · Image and Vision Computing · doi:10.1016/j.imavis.2025.105509 · Cited by 95
Lin, C., Chau, T., Lin, C.-S., Shang, H.-S., Fang, W.-H., Lee, D.-J., Lee, C.-C., Tsai, S.-H., Wang, C.-H., & Lin, S.-H. (2022) · npj Digital Medicine · doi:10.1038/s41746-021-00550-0 · Cited by 62
Oikonomou, E. K., Sangha, V., Dhingra, L. S., Aminorroaya, A., Coppi, A., Krumholz, H. M., Baldassarre, L. A., & Khera, R. (2025) · Circulation: Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.124.011504 · Cited by 60
Harmon, D. M., Mangold, K., Baez Suarez, A., Scott, C. G., Murphree, D. H., Malik, A., Attia, Z. I., Lopez-Jimenez, F., Friedman, P. A., Dispenzieri, A., et al. (2023) · JACC: Advances · doi:10.1016/j.jacadv.2023.100612 · Cited by 47
“14 While each of these AI models, including our own, has exhibited high accuracy and clinical promise, it remains critical to understand the strengths, limitations, and maintenance needs of each algorithm as they become increasingly accessible to practitioners in various clinical environments.”
Self-citationSiontis, K. C., Wieczorek, M. A., Maanja, M., Hodge, D. O., Kim, H.-K., Lee, H.-J., Lee, H., Lim, J., Park, C. S., Ariga, R., et al. (2024) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztae029 · Cited by 44
Self-citationArtificial intelligence and the electrocardiogram: A modern renaissance
Palermi, S., Vecchiato, M., Ng, F. S., Attia, Z., Cho, Y., Anselmino, M., De Ferrari, G. M., Saglietto, A., Sau, A., Chiu, I.-M., et al. (2025) · European Journal of Internal Medicine · doi:10.1016/j.ejim.2025.04.036 · Cited by 42
Self-citationArtificial intelligence-enhanced patient evaluation: bridging art and science
Oikonomou, E. K., & Khera, R. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae415 · Cited by 34
König, S., Hohenstein, S., Nitsche, A., Pellissier, V., Leiner, J., Stellmacher, L., Hindricks, G., & Bollmann, A. (2024) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztad081 · Cited by 21
“10,11 A high variance of performance results for external validation studies reflects both the necessity and difficulty of such analyses, which are influenced by the setting of model application.”
BackgroundArtificial intelligence-enabled electrocardiography from scientific research to clinical application
Lin, C.-S., Liu, W.-T., Chen, Y.-H., Lin, S.-H., & Lin, C. (2025) · EMBO Molecular Medicine · doi:10.1038/s44321-025-00351-y · Cited by 15
“AI-ECG has emerged not only as a diagnostic tool but also as a powerful method for risk strati fi cation and is capable of identifying “ previvors ” , de fi ned as individuals who appear healthy but harbor a high predisposition to disease (Attia et al, 2021).”
Palantzas, A., & Anagnostouli, M. (2025) · International Journal of Molecular Sciences · doi:10.3390/ijms26178217 · Cited by 11
“Prognostically, they predict HF up to 10 years in advance and AF within 6 months to 10 years and perform risk stratification for SCD, stroke, and mortality, even in patients with normal ECGs [191,193,194,196,197].”
Chase, A., Most, A., Sikora, A., Smith, S. E., Devlin, J. W., Xu, S., Liu, T., & Murray, B. (2026) · American Journal of Health-System Pharmacy · doi:10.1093/ajhp/zxaf168 · Cited by 11
Lin, C., Chen, C.-C., Chau, T., Lin, C.-S., Tsai, S.-H., Lee, D.-J., Lee, C.-C., Shang, H.-S., & Lin, S.-H. (2022) · Clinica Chimica Acta · doi:10.1016/j.cca.2022.09.021 · Cited by 10
Lin, C., Kuo, F.-C., Chau, T., Shih, J.-H., Lin, C.-S., Chen, C.-C., Lee, C.-C., & Lin, S.-H. (2024) · Communications Medicine · doi:10.1038/s43856-024-00472-4 · Cited by 8
Diagnosis of cardiac conditions from 12-lead electrocardiogram through natural language supervision
Zhou, X., Li, T., Hayama, H., Nakamura, K., Liu, S.-H., Chen, W., & Zhu, X. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-02074-3 · Cited by 8
Yang, C.-C., Lin, C.-S., Lin, C., Liu, W.-T., Lai, Z.-Y., & Chuang, Y.-J. (2026) · Internal and Emergency Medicine · doi:10.1007/s11739-025-04209-6 · Cited by 3
Metadata
- Authors
- Attia, Z. I., Harmon, D. M., Behr, E. R., & Friedman, P. A.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2021-09-17
- Volume
- 42
- Issue
- 46
- Pages
- 4717-4730
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W3199206152
- Cited by
- 312
- References
- 49
- FWCI
- 25.66
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.