Application of artificial intelligence to the electrocardiogram
Open accessThe DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
Artificial intelligence (AI) has given the electrocardiogram (ECG) and clinicians reading them super-human diagnostic abilities. Trained without hard-coded rules by finding often subclinical patterns in huge datasets, AI transforms the ECG, a ubiquitous, non-invasive cardiac test that is integrated into practice workflows, into a screening tool and predictor of cardiac and non-cardiac diseases, often in asymptomatic individuals. This review describes the mathematical background behind supervised AI algorithms, and discusses selected AI ECG cardiac screening algorithms including those for the detection of left ventricular dysfunction, episodic atrial fibrillation from a tracing recorded during normal sinus rhythm, and other structural and valvular diseases. The ability to learn from big data sets, without the need to understand the biological mechanism, has created opportunities for detecting non-cardiac diseases as COVID-19 and introduced challenges with regards to data privacy. Like all medical tests, the AI ECG must be carefully vetted and validated in real-world clinical environments. Finally, with mobile form factors that allow acquisition of medical-grade ECGs from smartphones and wearables, the use of AI may enable massive scalability to democratize healthcare.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Grad-CAM: Visual Explanations from Deep Networks via Gradient-Based Localization
Selvaraju, R. R., Cogswell, M., Das, A., Vedantam, R., Parikh, D., & Batra, D. (2017) · 2017 IEEE International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2017.74 · Cited by 24,513
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström-Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P. E., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 9,971
Survey on deep learning with class imbalance
Johnson, J. M., & Khoshgoftaar, T. M. (2019) · Journal of Big Data · doi:10.1186/s40537-019-0192-5 · Cited by 3,032
Cryptogenic stroke and underlying atrial fibrillation
Sanna, T., Diener, H.-C., Passman, R. S., Di Lazzaro, V., Bernstein, R. A., Morillo, C. A., Rymer, M. M., Thijs, V., Rogers, T., Beckers, F., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1313600 · Cited by 2,161 · cited 2×
“14,38 In patients with embolic stroke of uncertain source, the choice of anti-platelet vs. anticoagulant therapy depends on the absence or presence of AF.”
Attia, Z. I., Noseworthy, P. A., Lopez-Jimenez, F., Asirvatham, S. J., Deshmukh, A. J., Gersh, B. J., Carter, R. E., Yao, X., Rabinstein, A. A., Erickson, B. J., et al. (2019) · The Lancet · doi:10.1016/s0140-6736(19)31721-0 · Cited by 1,613 · cited 2×
“2,3,13,14 17 The ECG is a rapid, cost-effective, point-of-care test that requires no blood and no reagents, that is massively scalable with smartphone technology to medical and non-medical environments.”
Self-citationAttia, Z. I., Kapa, S., Lopez-Jimenez, F., McKie, P. M., Ladewig, D. J., Satam, G., Pellikka, P. A., Enriquez-Sarano, M., Noseworthy, P. A., Munger, T. M., et al. (2019) · Nature Medicine · doi:10.1038/s41591-018-0240-2 · Cited by 1,389 · cited 3×
“2,3,13,14 17 The ECG is a rapid, cost-effective, point-of-care test that requires no blood and no reagents, that is massively scalable with smartphone technology to medical and non-medical environments.”
Self-citationArtificial intelligence-enhanced electrocardiography in cardiovascular disease management
Siontis, K. C., Noseworthy, P. A., Attia, Z. I., & Friedman, P. A. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-00503-2 · Cited by 914
Self-citationPassive Detection of Atrial Fibrillation Using a Commercially Available Smartwatch
Tison, G. H., Sanchez, J. M., Ballinger, B., Singh, A., Olgin, J. E., Pletcher, M. J., Vittinghoff, E., Lee, E. S., Fan, S. M., Gladstone, R. A., et al. (2018) · JAMA Cardiology · doi:10.1001/jamacardio.2018.0136 · Cited by 566
Electrocardiographic interpretation in athletes: the ‘Seattle Criteria’
Drezner, J. A., Ackerman, M. J., Anderson, J., Ashley, E., Asplund, C. A., Baggish, A. L., Börjesson, M., Cannon, B. C., Corrado, D., DiFiori, J. P., et al. (2013) · British Journal of Sports Medicine · doi:10.1136/bjsports-2012-092067 · Cited by 550
Early Surgery or Conservative Care for Asymptomatic Aortic Stenosis
Kang, D.-H., Park, S.-J., Lee, S.-A., Lee, S., Kim, D.-H., Kim, H.-K., Yun, S.-C., Hong, G.-R., Song, J.-M., Chung, C.-H., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa1912846 · Cited by 537 · cited 1×
“48 Current screening methods rely on expert examination and auscultation that prompt echocardiography.”
Age and Sex Estimation Using Artificial Intelligence From Standard 12-Lead ECGs
Attia, Z. I., Friedman, P. A., Noseworthy, P. A., Lopez-Jimenez, F., Ladewig, D. J., Satam, G., Pellikka, P. A., Munger, T. M., Asirvatham, S. J., Scott, C. G., et al. (2019) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.119.007284 · Cited by 455
Self-citationYao, X., Rushlow, D. R., Inselman, J. W., McCoy, R. G., Thacher, T. D., Behnken, E. M., Bernard, M. E., Rosas, S. L., Akfaly, A., Misra, A., et al. (2021) · Nature Medicine · doi:10.1038/s41591-021-01335-4 · Cited by 424 · cited 1×
“The EAGLE study 50 and Yao et al. 36 were a pragmatic clustered trial study that randomized 120 primary care teams including 358 clinicians to an intervention group (access to AI screening results, 181 clinicians) or control (usual care, 177 clinicians), across 48 clinics/hospitals.”
Self-citationKo, W.-Y., Siontis, K. C., Attia, Z. I., Carter, R. E., Kapa, S., Ommen, S. R., Demuth, S. J., Ackerman, M. J., Gersh, B. J., Arruda-Olson, A. M., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.12.030 · Cited by 404 · cited 2×
“2,3,13,14 17 The ECG is a rapid, cost-effective, point-of-care test that requires no blood and no reagents, that is massively scalable with smartphone technology to medical and non-medical environments.”
Self-citationSheikh, N., Papadakis, M., Ghani, S., Zaidi, A., Gati, S., Adami, P. E., Carré, F., Schnell, F., Wilson, M., Avila, P., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.006179 · Cited by 324
Galloway, C. D., Valys, A. V., Shreibati, J. B., Treiman, D. L., Petterson, F. L., Gundotra, V. P., Albert, D. E., Attia, Z. I., Carter, R. E., Asirvatham, S. J., et al. (2019) · JAMA Cardiology · doi:10.1001/jamacardio.2019.0640 · Cited by 318
Self-citationRaghunath, S., Pfeifer, J. M., Ulloa-Cerna, A. E., Nemani, A., Carbonati, T., Jing, L., vanMaanen, D. P., Hartzel, D. N., Ruhl, J. A., Lagerman, B. F., et al. (2021) · Circulation · doi:10.1161/circulationaha.120.047829 · Cited by 312
Seet, R. C. S., Friedman, P. A., & Rabinstein, A. A. (2011) · Circulation · doi:10.1161/circulationaha.111.029801 · Cited by 276
Self-citationRedfield, M. M., Rodeheffer, R. J., Jacobsen, S. J., Mahoney, D. W., Bailey, K. R., & Burnett, J. C. (2004) · Circulation · doi:10.1161/01.cir.0000130845.38133.8f · Cited by 264
Electrocardiogram screening for aortic valve stenosis using artificial intelligence
Cohen-Shelly, M., Attia, Z. I., Friedman, P. A., Ito, S., Essayagh, B. A., Ko, W.-Y., Murphree, D. H., Michelena, H. I., Enriquez-Sarano, M., Carter, R. E., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab153 · Cited by 252 · cited 2×
“In published valvular disease detection algorithms, for example, 6,7 the authors use saliency-based methods to highlight the portions of the ECG that contributed to the model’s output in selected samples.”
Self-citationDeep Learning–Based Algorithm for Detecting Aortic Stenosis Using Electrocardiography
Kwon, J., Lee, S. Y., Jeon, K., Lee, Y., Kim, K., Park, J., Oh, B., & Lee, M. (2020) · Journal of the American Heart Association · doi:10.1161/jaha.119.014717 · Cited by 224 · cited 1×
“In published valvular disease detection algorithms, for example, 6,7 the authors use saliency-based methods to highlight the portions of the ECG that contributed to the model’s output in selected samples.”
Noseworthy, P. A., Attia, Z. I., Brewer, L. C., Hayes, S. N., Yao, X., Kapa, S., Friedman, P. A., & Lopez-Jimenez, F. (2020) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.119.007988 · Cited by 220
Self-citationAutomated and interpretable patient ECG profiles for disease detection, tracking, and discovery
Tison, G. H., Zhang, J., Delling, F. N., & Deo, R. C. (2019) · Circulation: Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.118.005289 · Cited by 208
Ethics of using and sharing clinical imaging data for artificial intelligence: a proposed framework
Larson, D. B., Magnus, D. C., Lungren, M. P., Shah, N. H., & Langlotz, C. P. (2020) · Radiology · doi:10.1148/radiol.2020192536 · Cited by 199 · cited 1×
“Sharing identified health information without proper approval is unethical, 54 risks eroding trust in health care institutions, and violates national and international laws, including HIPAA in the USA 55 and GDPR in Europe 56 To avoid infringing on patient privacy and to comply with regulations,…”
Attia, Z. I., Kapa, S., Yao, X., Lopez‐Jimenez, F., Mohan, T. L., Pellikka, P. A., Carter, R. E., Shah, N. D., Friedman, P. A., & Noseworthy, P. A. (2019) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13889 · Cited by 196
Self-citationAdedinsewo, D., Carter, R. E., Attia, Z., Johnson, P., Kashou, A. H., Dugan, J. L., Albus, M., Sheele, J. M., Bellolio, F., Friedman, P. A., et al. (2020) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.120.008437 · Cited by 169
Self-citationExplainable artificial intelligence to detect atrial fibrillation using electrocardiogram
Jo, Y., Cho, Y., Lee, S. Y., Kwon, J., Kim, K., Jeon, K., Cho, S., Park, J., & Oh, B. (2020) · International Journal of Cardiology · doi:10.1016/j.ijcard.2020.11.053 · Cited by 144
Alizadehsani, R., Roshanzamir, M., Hussain, S., Khosravi, A., Koohestani, A., Zangooei, M. H., Abdar, M., Beykikhoshk, A., Shoeibi, A., Zare, A., et al. (2024) · Annals of Operations Research · doi:10.1007/s10479-021-04006-2 · Cited by 143
Bos, J. M., Attia, Z. I., Albert, D. E., Noseworthy, P. A., Friedman, P. A., & Ackerman, M. J. (2021) · JAMA Cardiology · doi:10.1001/jamacardio.2020.7422 · Cited by 142
Self-citationDeep learning models for electrocardiograms are susceptible to adversarial attack
Han, X., Hu, Y., Foschini, L., Chinitz, L., Jankelson, L., & Ranganath, R. (2020) · Nature Medicine · doi:10.1038/s41591-020-0791-x · Cited by 139
Predicting atrial fibrillation in primary care using machine learning
Hill, N. R., Ayoubkhani, D., McEwan, P., Sugrue, D. M., Farooqui, U., Lister, S., Lumley, M., Bakhai, A., Cohen, A. T., O’Neill, M., et al. (2019) · PLOS ONE · doi:10.1371/journal.pone.0224582 · Cited by 137
Kwon, J.-M., Kim, K.-H., Jeon, K.-H., Kim, H. M., Kim, M. J., Lim, S.-M., Song, P. S., Park, J., Choi, R. K., & Oh, B.-H. (2019) · Korean Circulation Journal · doi:10.4070/kcj.2018.0446 · Cited by 133
Giudicessi, J. R., Schram, M., Bos, J. M., Galloway, C. D., Shreibati, J. B., Johnson, P. W., Carter, R. E., Disrud, L. W., Kleiman, R., Attia, Z. I., et al. (2021) · Circulation · doi:10.1161/circulationaha.120.050231 · Cited by 129
Self-citationChristopoulos, G., Graff-Radford, J., Lopez, C. L., Yao, X., Attia, Z. I., Rabinstein, A. A., Petersen, R. C., Knopman, D. S., Mielke, M. M., Kremers, W., et al. (2020) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.120.009355 · Cited by 126
Self-citationDiagnostic assessment of a deep learning system for detecting atrial fibrillation in pulse waveforms
Poh, M.-Z., Poh, Y. C., Chan, P.-H., Wong, C.-K., Pun, L., Leung, W. W.-C., Wong, Y.-F., Wong, M. M.-Y., Chu, D. W.-S., & Siu, C.-W. (2018) · Heart · doi:10.1136/heartjnl-2018-313147 · Cited by 120
Betti, I., Castelli, G., Barchielli, A., Beligni, C., Boscherini, V., Luca, L. D., Messeri, G., Gheorghiade, M., Maisel, A., & Zuppiroli, A. (2009) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2008.12.002 · Cited by 111
Utilizing ECG-Based Heartbeat Classification for Hypertrophic Cardiomyopathy Identification
Rahman, Q. A., Tereshchenko, L. G., Kongkatong, M., Abraham, T., Abraham, M. R., & Shatkay, H. (2015) · IEEE Transactions on NanoBioscience · doi:10.1109/tnb.2015.2426213 · Cited by 101
Yao, X., McCoy, R. G., Friedman, P. A., Shah, N. D., Barry, B. A., Behnken, E. M., Inselman, J. W., Attia, Z. I., & Noseworthy, P. A. (2020) · American Heart Journal · doi:10.1016/j.ahj.2019.10.007 · Cited by 98 · cited 3×
“36”
Self-citationCho, J., Lee, B., Kwon, J.-M., Lee, Y., Park, H., Oh, B.-H., Jeon, K.-H., Park, J., & Kim, K.-H. (2021) · ASAIO Journal · doi:10.1097/mat.0000000000001218 · Cited by 91
Dai, H., Hwang, H.-G., & Tseng, V. S. (2021) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2021.106035 · Cited by 81 · cited 1×
“25,34,46 The Mayo Clinic al-gorithm maintained its robust accuracy when the testing group was narrowed to patients with left ventricular hypertrophy (LVH) ECG criteria (AUC 0.95) and ‘normal ECG’ by manual interpretation (AUC 0.95), as found by others.”
InfluentialExternal validation of a deep learning electrocardiogram algorithm to detect ventricular dysfunction
Attia, I. Z., Tseng, A. S., Benavente, E. D., Medina-Inojosa, J. R., Clark, T. G., Malyutina, S., Kapa, S., Schirmer, H., Kudryavtsev, A. V., Noseworthy, P. A., et al. (2021) · International Journal of Cardiology · doi:10.1016/j.ijcard.2020.12.065 · Cited by 80
Self-citationArtificial intelligence for detecting mitral regurgitation using electrocardiography
Kwon, J.-M., Kim, K.-H., Akkus, Z., Jeon, K.-H., Park, J., & Oh, B.-H. (2020) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2020.02.008 · Cited by 79
Bhattacharya, M., Lu, D., Kudchadkar, S. M., Greenland, G. V., Lingamaneni, P., Corona‐Villalobos, C. P., Guan, Y., Marine, J. E., Olgin, J. E., Zimmerman, S. L., et al. (2019) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2019.02.022 · Cited by 74
Comparison of three ECG criteria for athlete pre-participation screening
Pickham, D. M., Zarafshar, S., Sani, D., Kumar, N., & Froelicher, V. F. (2014) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2014.07.019 · Cited by 68
Harms and benefits of screening young people to prevent sudden cardiac death
Brabandt, H. V., Desomer, A., Gerkens, S., & Neyt, M. (2016) · BMJ · doi:10.1136/bmj.i1156 · Cited by 59
Uncertainty estimation for deep learning-based automated analysis of 12-lead electrocardiograms
Vranken, J. F., van de Leur, R. R., Gupta, D. K., Juárez‐Orozco, L. E., Hassink, R. J., van der Harst, P., Doevendans, P. A., Gulshad, S., & van Es, R. (2021) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztab045 · Cited by 53
Artificial Intelligence ECG to Detect Left Ventricular Dysfunction in COVID-19
Attia, Z. I., Kapa, S., Noseworthy, P. A., Lopez-Jimenez, F., & Friedman, P. A. (2020) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2020.09.020 · Cited by 39
Self-citationScreening for Asymptomatic Left Ventricular Dysfunction Using B‐Type Natriuretic Peptide
McDonagh, T. A., McDonald, K., & Maisel, A. S. (2008) · Congestive Heart Failure · doi:10.1111/j.1751-7133.2008.tb00002.x · Cited by 35 · cited 1×
“2,3,13,14 17 The ECG is a rapid, cost-effective, point-of-care test that requires no blood and no reagents, that is massively scalable with smartphone technology to medical and non-medical environments.”
Noseworthy, P. A., Attia, Z. I., Carter, R. E., Yao, X., & Friedman, P. A. (2020) · The Lancet · doi:10.1016/s0140-6736(20)31064-3 · Cited by 7
Self-citationAn AI-ECG algorithm for atrial fibrillation risk: steps towards clinical implementation
Freedman, B. (2020) · The Lancet · doi:10.1016/s0140-6736(20)31063-1 · Cited by 5
Cited by
Artificial intelligence in clinical medicine: catalyzing a sustainable global healthcare paradigm
Krishnan, G., Singh, S., Pathania, M., Gosavi, S., Abhishek, S., Parchani, A., & Dhar, M. (2023) · Frontiers in Artificial Intelligence · doi:10.3389/frai.2023.1227091 · Cited by 296
Prospective evaluation of smartwatch-enabled detection of left ventricular dysfunction
Attia, Z. I., Harmon, D. M., Dugan, J., Manka, L., Lopez-Jimenez, F., Lerman, A., Siontis, K. C., Noseworthy, P. A., Yao, X., Klavetter, E. W., et al. (2022) · Nature Medicine · doi:10.1038/s41591-022-02053-1 · Cited by 154
Self-citationLin, C.-S., Liu, W.-T., Tsai, D.-J., Lou, Y.-S., Chang, C.-H., Lee, C.-C., Fang, W.-H., Wang, C.-C., Chen, Y.-Y., Lin, W.-S., et al. (2024) · Nature Medicine · doi:10.1038/s41591-024-02961-4 · Cited by 115
“Physicians may order additional tests based on previous evidence that the AI-ECG identified subtle changes in underlying cardiac diseases 34 , particularly low EF 17 and paroxysmal atrial fibrillation 18 .”
A systematic review of intermediate fusion in multimodal deep learning for biomedical applications
Guarrasi, V., Aksu, F., Caruso, C. M., Di Feola, F., Rofena, A., Ruffini, F., & Soda, P. (2025) · Image and Vision Computing · doi:10.1016/j.imavis.2025.105509 · Cited by 95
Lin, C., Chau, T., Lin, C.-S., Shang, H.-S., Fang, W.-H., Lee, D.-J., Lee, C.-C., Tsai, S.-H., Wang, C.-H., & Lin, S.-H. (2022) · npj Digital Medicine · doi:10.1038/s41746-021-00550-0 · Cited by 62
Metadata
- Authors
- Attia, Z. I., Harmon, D. M., Behr, E. R., & Friedman, P. A.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2021-09-17
- Volume
- 42
- Issue
- 46
- Pages
- 4717-4730
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W3199206152
- Cited by
- 312
- References
- 49
- FWCI
- 25.66
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.