Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 239

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Assessment of flow-mediated vasodilatation (FMD) of the brachial artery: effects of technical aspects of the FMD measurement on the FMD response

Bots, Michiel L., Westerink, Jan, Rabelink, Ton J., de Koning, Eelco J.P. · 2005 · European Heart Journal

Abstract

AIMS: The ability to assess endothelial function non-invasively with B-mode ultrasound has lead to its widespread application in a variety of studies. However, the absolute values obtained using this approach vary considerably across studies. We studied whether technical aspects of the methodology can explain the wide variety in absolute values across studies. METHODS AND RESULTS: A literature search was performed to identify published reports on flow-mediated vasodilatation (FMD) of the brachial artery published between 1992 and 2001. Information on type of equipment (wall track/B-mode), location of the measurement (antecubital fossa/upper arm), occlusion site (lower/upper arm), occlusion duration (min), and occlusion pressure was extracted. Patient characteristics were also extracted. For the healthy populations, mean FMD varied from 0.20 to 19.2%; for the coronary heart disease (CHD) patients FMD varied from -1.3 to 14%; for subjects with diabetes mellitus FMD varied from 0.75 to 12%. Compared with occlusion at the upper arm, lower arm occlusion was related to decreased FMD (mean difference in FMD -2.47%; 95% CI 0.55-4.39). An occlusion duration of > or =4.5 min was related to an increased FMD compared with an occlusion time of < or =4 min (mean difference 1.30%; 95% CI 0.35-2.46). These findings were adjusted for other technical aspects of the methodology and for differences in risk factors between populations. CONCLUSION: Mean FMD differs widely between studies. There is a great overlap between populations (healthy, CHD, diabetics). Our findings suggest that the technical aspects of the measurements, the location, and the duration of the occlusion may explain some of these differences, whereas type of equipment, location of the measurement, and occlusion pressure do not.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurheartj/ehi017

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 239

Metadata

Authors
Bots, M. L., Westerink, J., Rabelink, T. J., & de Koning, E. J. P.
Venue
European Heart Journal
Published
2004-12-01
Volume
26
Issue
4
Pages
363-368
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2114026317
Cited by
239
References
7
FWCI
6.61
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of flow-mediated vasodilatation (FMD) of the brachial artery: effects of technical aspects of the FMD measurement on the FMD response. https://app.cochat.ai/papers/10.1093/eurheartj/ehi017
The paper
Bots, M. L., Westerink, J., Rabelink, T. J., & de Koning, E. J. P. (2005). Assessment of flow-mediated vasodilatation (FMD) of the brachial artery: effects of technical aspects of the FMD measurement on the FMD response. European Heart Journal. https://doi.org/10.1093/eurheartj/ehi017

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.