Radiofrequency ablation of arrhythmias guided by non-fluoroscopic catheter location: a prospective randomized trial
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
AIMS: To compare the utility of non-fluoroscopic mapping systems (Carto and Ensite NavX) with that of conventional mapping in patients referred for catheter ablation of a wide variety of arrhythmias. METHODS AND RESULTS: Patients referred for catheter ablation (excluding atrial fibrillation, atypical atrial flutter, ventricular tachycardia in structural heart disease, and complete AV nodal ablation) were randomized equally to a procedure guided by Carto, Ensite NavX, or conventional mapping. A total of 145 patients were recruited (82 men, aged 49+/-16, range 18-85). In 19 patients, no ablation was performed, and in the remaining, typical atrial flutter, atrioventricular nodal re-entrant tachycardia, and atrioventricular re-entrant tachycardias [including Wolff-Parkinson-White (WPW)] accounted for 93% of ablations. Overall procedure time, immediate and short-term success, complication rate, and freedom from symptoms at follow-up were identical for all groups. NavX led to the least X-ray exposure: Navx vs. conventional, median (range): 4 (0-50) vs. 13 (2-46) min (P<0.001); NavX vs. Carto, median (range): 4 (0-50) vs. 6 (1-55) min (P=0.008). Both Carto and NavX increased disposable costs by 50% when compared with conventional (P<0.001). For typical atrial flutter, Carto and NavX reduced screening times without increasing procedure cost. If ablation was not performed, NavX was twice as expensive as Carto or conventional. CONCLUSION: Ensite NavX and Carto procedures have similar effectiveness and safety to a conventional approach; however, they both reduce X-ray exposure, with NavX producing a significantly greater effect than Carto. Although this benefit is achieved at a greater financial cost, there may be long-term benefits to catheter laboratory staff.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kovoor, P., Ricciardello, M., Collins, L., Uther, J. B., & Ross, D. L. (1998) · Circulation · doi:10.1161/01.cir.98.15.1534 · Cited by 184 · cited 1×
“X-ray during catheter ablation is associated with an increased lifetime risk of malignancy and all possible measures should be taken to minimize exposure.(1,2) Nonfluoroscopic mapping technology has been of great value in the ablation of complex arrhythmias such as atrial fibrillation, atypical atrial flutter, and ven…”
BackgroundPerisinakis, K., Damilakis, J., Theocharopoulos, N., Manios, E., Vardas, P., & Gourtsoyiannis, N. (2001) · Circulation · doi:10.1161/hc2601.091710 · Cited by 176 · cited 1×
“X-ray during catheter ablation is associated with an increased lifetime risk of malignancy and all possible measures should be taken to minimize exposure.(1,2) Nonfluoroscopic mapping technology has been of great value in the ablation of complex arrhythmias such as atrial fibrillation, atypical atrial flutter, and ven…”
BackgroundSPORTON, S. C., EARLEY, M. J., NATHAN, A. W., & SCHILLING, R. J. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2004.03356.x · Cited by 151 · cited 3×
“Location of the ablation catheter using magnetic fields (electro-anatomic mapping, CartoTM, Biosense Webster, Diamond Bar, CA, USA) reduces radiation exposure.(4,5) This technology allows the construction of a three-dimensional geometry to guide catheter navigation and ablation lesion placement; however, it is not pos…”
BackgroundMethodResultSelf-citationRotter, M., Takahashi, Y., Sanders, P., Haı̈ssaguerre, M., Jaı̈s, P., Hsu, L., Sacher, F., Pasquié, J., Clémenty, J., & Hocini, M. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi172 · Cited by 141
Kottkamp, H., Hügl, B. J., Krauss, B., Wetzel, U., Fleck, A., Schuler, G. C., & Hindricks, G. (2000) · Circulation · doi:10.1161/01.cir.102.17.2082 · Cited by 137 · cited 2×
“2 min.(4,11) In another trial of 40 patients using NavX, a comparable reduction was found (24.”
MethodWILLEMS, S., WEISS, C., VENTURA, R., RÜPPEL, R., RISIUS, T., HOFFMANN, M., & MEINERTZ, T. (2000) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2000.01223.x · Cited by 112 · cited 1×
“2 min.(4,11) In another trial of 40 patients using NavX, a comparable reduction was found (24.”
Kirchhof, P. F., Loh, P. K. K., Eckardt, L., Ribbing, M., Rolf, S., EICK, O. J., Wittkampf, F. H. M., Borggrefe, M., Breithardt, G. Ü., & Haverkamp, W. (2002) · The American Journal of Cardiology · doi:10.1016/s0002-9149(02)02481-5 · Cited by 42 · cited 1×
“, Minneapolis, MN, USA), which has also demonstrated reduced screening times.(6,7) A further technology, Ensite NavXTM (St Jude Medical, St Paul, MN, USA), combines the ability to locate all catheters non-fluoroscopically and, if necessary, construct a three-dimensional geometry.”
BackgroundKopelman, H. A. (2003) · EP Europace · doi:10.1053/eupc.2002.0296 · Cited by 39 · cited 1×
“2 min.(12) In our own laboratory, we have previously demonstrated across a wide variety of arrhythmias that Carto drastically reduces the need for screening when compared with the conventional approach.”
Background
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Self-citationCalkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
Self-citationCalkins, H., Hindricks, G., Cappato, R., Kim, Y., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Journal of Arrhythmia · doi:10.1016/j.joa.2017.08.001 · Cited by 707
Self-citationPage, R. L., Joglar, J. A., Caldwell, M. A., Calkins, H., Conti, J. B., Deal, B. J., Estes, N. A. M., Field, M. E., Goldberger, Z. D., Hammill, S. C., et al. (2016) · Circulation · doi:10.1161/cir.0000000000000311 · Cited by 595
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux275 · Cited by 509
Self-citation2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2019) · EP Europace · doi:10.1093/europace/euz132 · Cited by 475
2015 ACC/AHA/HRS Guideline for the Management of Adult Patients With Supraventricular Tachycardia
Page, R. L., Joglar, J. A., Caldwell, M. A., Calkins, H., Conti, J. B., Deal, B. J., Estes, N. A. M., Field, M. E., Goldberger, Z. D., Hammill, S. C., et al. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.08.856 · Cited by 439
2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2019.03.002 · Cited by 431
Heidbuchel, H., Wittkampf, F. H. M., Vano, E., Ernst, S., Schilling, R., Picano, E., Mont, L., ESC Scientific Document Group, Jais, P., de Bono, J., et al. (2014) · EP Europace · doi:10.1093/europace/eut409 · Cited by 311
Self-citation2015 ACC/AHA/HRS guideline for the management of adult patients with supraventricular tachycardia
Page, R. L., Joglar, J. A., Caldwell, M. A., Calkins, H., Conti, J. B., Deal, B. J., Estes III, N. A. M., Field, M. E., Goldberger, Z. D., Hammill, S. C., et al. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2015.09.019 · Cited by 206
MARTINEK, M., NESSER, H., AICHINGER, J., BOEHM, G., & PURERFELLNER, H. (2007) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2007.00843.x · Cited by 193
Page, R. L., Joglar, J. A., Caldwell, M. A., Calkins, H., Conti, J. B., Deal, B. J., Estes, N. A. M., Field, M. E., Goldberger, Z. D., Hammill, S. C., et al. (2016) · Circulation · doi:10.1161/cir.0000000000000310 · Cited by 175
“intracardiac echocardiography, have led to the ability to perform SVT ablation with no or minimal fluoroscopy, with success and complication rates similar to standard techniques (147, 149-152).”
Method
Metadata
- Authors
- Earley, M. J., Showkathali, R., Alzetani, M., Kistler, P. M., Gupta, D., Abrams, D. J., Horrocks, J. A., Harris, S. J., Sporton, S. C., & Schilling, R. J.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-04-13
- Volume
- 27
- Issue
- 10
- Pages
- 1223-1229
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2170276366
- Cited by
- 201
- References
- 8
- FWCI
- 5.91
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.