Mortality in randomized controlled trials comparing drug-eluting vs. bare metal stents in coronary artery disease: a meta-analysis
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
AIMS: To evaluate the effect of drug-eluting vs. bare metal stents for the treatment of coronary artery disease on overall, cardiac, and non-cardiac mortalities. METHODS AND RESULTS: We conducted a systematic literature search to identify all randomized controlled trials comparing sirolimus or paclitaxel-eluting stents with bare metal stents and reporting mortality data after at least 1 year of follow-up. Trial data were reviewed and extracted independently by two investigators in an unblinded standardized manner. Seventeen trials including a total of 8221 patients were analysed. Peto's odds ratios (ORs) for total mortality after 1 (n=8221), 2 (n=4631), 3 (n=4105), and 4 (n=1293) years of follow-up were 0.94 [95% confidence interval (CI) 0.66-1.34], 1.11 (95% CI 0.76-1.61), 1.25 (95% CI 0.91-1.73), and 1.46 (95% CI 0.92-2.31), respectively. Corresponding ORs for non-cardiac mortality were 1.07 (95% CI 0.64-1.80), 1.72 (95% CI 1.01-2.94), 1.45 (95% CI 0.93-2.25), and 1.65 (95% CI 0.89-3.10). There was no difference in OR for cardiac mortality among all trials. In sensitivity analyses, sirolimus- but not paclitaxel-eluting stents were associated with an increase in non-cardiac mortality at 2 and 3 years of follow-up. CONCLUSION: Drug-eluting stents for the treatment of coronary artery disease do not reduce total mortality when compared with bare metal stents. Preliminary evidence suggests that sirolimus- but not paclitaxel-eluting stents may lead to increased non-cardiac mortality. Long-term follow-up and assessment of cause-specific deaths in patients receiving drug-eluting stents is mandatory to determine the long-term safety of these devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139
Serruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310801 · Cited by 4,556
Moses, J. W., Leon, M. B., Popma, J. J., Fitzgerald, P. J., Holmes, D. R., O'Shaughnessy, C., Caputo, R. P., Kereiakes, D. J., Williams, D. O., Teirstein, P. S., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035071 · Cited by 4,224
Morice, M.-C., Serruys, P. W., Sousa, J. E., Fajadet, J., Ban Hayashi, E., Perin, M., Colombo, A., Schuler, G., Barragan, P., Guagliumi, G., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012843 · Cited by 4,033
A Polymer-Based, Paclitaxel-Eluting Stent in Patients with Coronary Artery Disease
Stone, G. W., Ellis, S. G., Cox, D. A., Hermiller, J., O'Shaughnessy, C., Mann, J. T., Turco, M., Caputo, R., Bergin, P., Greenberg, J., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032441 · Cited by 2,749
Investigating and dealing with publication and other biases in meta-analysis
Sterne, J. A. C., Egger, M., & Smith, G. D. (2001) · BMJ · doi:10.1136/bmj.323.7304.101 · Cited by 2,225
The Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
What to add to nothing? Use and avoidance of continuity corrections in meta‐analysis of sparse data
J. Sweeting, M., J. Sutton, A., & C. Lambert, P. (2004) · Statistics in Medicine · doi:10.1002/sim.1761 · Cited by 1,734
Late thrombosis in drug-eluting coronary stents after discontinuation of antiplatelet therapy
McFadden, E. P., Stabile, E., Regar, E., Cheneau, E., Ong, A. T., Kinnaird, T., Suddath, W. O., Weissman, N. J., Torguson, R., Kent, K. M., et al. (2004) · The Lancet · doi:10.1016/s0140-6736(04)17275-9 · Cited by 1,436
Patterns and Mechanisms of In-Stent Restenosis: A Serial Intravascular Ultrasound Study
Hoffmann, R., Mintz, G. S., Dussaillant, G. R., Popma, J. J., Pichard, A. D., Satler, L. F., Kent, K. M., Griffin, J., & Leon, M. B. (1996) · Circulation · doi:10.1161/01.cir.94.6.1247 · Cited by 1,247
Colombo, A., Drzewiecki, J., Banning, A., Grube, E., Hauptmann, K., Silber, S., Dudek, D., Fort, S., Schiele, F., Zmudka, K., et al. (2003) · Circulation · doi:10.1161/01.cir.0000086926.62288.a6 · Cited by 1,016
Schofer, J., Schlüter, M., Gershlick, A. H., Wijns, W., Garcia, E., Schampaert, E., & Breithardt, G. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14462-5 · Cited by 955
Stone, G. W., Ellis, S. G., Cannon, L., Mann, J. T., Greenberg, J. D., Spriggs, D., O'Shaughnessy, C. D., DeMaio, S., Hall, P., Popma, J. J., et al. (2005) · JAMA · doi:10.1001/jama.294.10.1215 · Cited by 765
Stone, G. W., Ellis, S. G., Cox, D. A., Hermiller, J., O’Shaughnessy, C., Mann, J. T., Turco, M., Caputo, R., Bergin, P., Greenberg, J., et al. (2004) · Circulation · doi:10.1161/01.cir.0000127110.49192.72 · Cited by 759
Serruys, P. W., van Hout, B., Bonnier, H., Legrand, V., Garcia, E., Macaya, C., Sousa, E., van der Giessen, W., Colombo, A., Seabra-Gomes, R., et al. (1998) · The Lancet · doi:10.1016/s0140-6736(97)11128-x · Cited by 650
A hierarchical Bayesian meta-analysis of randomised clinical trials of drug-eluting stents
Babapulle, M. N., Joseph, L., Bélisle, P., Brophy, J. M., & Eisenberg, M. J. (2004) · The Lancet · doi:10.1016/s0140-6736(04)16850-5 · Cited by 645
Schampaert, E., Cohen, E. A., Schlüter, M., Reeves, F., Traboulsi, M., Title, L. M., Kuntz, R. E., & Popma, J. J. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.01.024 · Cited by 575
A Paclitaxel-Eluting Stent for the Prevention of Coronary Restenosis
Park, S.-J., Shim, W. H., Ho, D. S., Raizner, A. E., Park, S.-W., Hong, M.-K., Lee, C. W., Choi, D., Jang, Y., Lam, R., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa021007 · Cited by 456
Sabaté, M., Jiménez-Quevedo, P., Angiolillo, D. J., Gómez-Hospital, J. A., Alfonso, F., Hernández-Antolín, R., Goicolea, J., Bañuelos, C., Escaned, J., Moreno, R., et al. (2005) · Circulation · doi:10.1161/circulationaha.105.562421 · Cited by 368
Kaiser, C., Brunner-La Rocca, H. P., Buser, P. T., Bonetti, P. O., Osswald, S., Linka, A., Bernheim, A., Zutter, A., Zellweger, M., Grize, L., et al. (2005) · The Lancet · doi:10.1016/s0140-6736(05)67221-2 · Cited by 342
Ardissino, D., Cavallini, C., Bramucci, E., Indolfi, C., Marzocchi, A., Manari, A., Angeloni, G., Carosio, G., Bonizzoni, E., Colusso, S., et al. (2004) · JAMA · doi:10.1001/jama.292.22.2727 · Cited by 314
Kastrati, A., Dibra, A., Eberle, S., Mehilli, J., Suárez de Lezo, J., Goy, J.-J., Ulm, K., & Schömig, A. (2005) · JAMA · doi:10.1001/jama.294.7.819 · Cited by 282
Gershlick, A., De Scheerder, I., Chevalier, B., Stephens-Lloyd, A., Camenzind, E., Vrints, C., Reifart, N., Missault, L., Goy, J.-J., Brinker, J. A., et al. (2004) · Circulation · doi:10.1161/01.cir.0000109694.58299.a0 · Cited by 237
Kastrati, A., Dibra, A., & Eberle, S. (2005) · ACC Current Journal Review · doi:10.1016/j.accreview.2005.10.047 · Cited by 235
Al Suwaidi, J. (2000) · JAMA · doi:10.1001/jama.284.14.1828 · Cited by 211
Lansky, A. J., Costa, R. A., Mintz, G. S., Tsuchiya, Y., Midei, M., Cox, D. A., O’Shaughnessy, C., Applegate, R. A., Cannon, L. A., Mooney, M., et al. (2004) · Circulation · doi:10.1161/01.cir.0000127129.94129.6f · Cited by 200
Two-Year Outcomes After Sirolimus-Eluting Stent Implantation
Weisz, G., Leon, M. B., Holmes, D. R., Kereiakes, D. J., Clark, M. R., Cohen, B. M., Ellis, S. G., Coleman, P. S., Hill, C., Shi, C., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.11.077 · Cited by 157
Meta-analysis of rare and adverse event data
Sutton, A. J., Cooper, N. J., Lambert, P. C., Jones, D. R., Abrams, K. R., & Sweeting, M. J. (2002) · Expert Review of Pharmacoeconomics & Outcomes Research · doi:10.1586/14737167.2.4.367 · Cited by 141
Drug-eluting stents: an early systematic review to inform policy*1, *2
Hill, R. A. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.03.023 · Cited by 137
Nordmann, A., Hengstler, P., Harr, T., Young, J. B., & Bucher, H. (2004) · American Journal of Medicine · doi:10.1016/j.amjmed.2003.08.035 · Cited by 124
Self-citationMeta-analysis comparing drug-eluting stents with bare metal stents
Katritsis, D. G., Karvouni, E., & Ioannidis, J. P. A. (2005) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2004.10.041 · Cited by 93
Ten years of sirolimus therapy in orthotopic liver transplant recipients
Neff, G. W., Montalbano, M., & Tzakis, A. G. (2003) · Transplantation Proceedings · doi:10.1016/s0041-1345(03)00217-3 · Cited by 83
Kereiakes, D. J., Kuntz, R. E., Mauri, L., & Krucoff, M. W. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.01.005 · Cited by 68
Nordmann, A., Hengstler, P., Leimenstoll, B., Harr, T., Young, J. B., & Bucher, H. (2004) · European Heart Journal · doi:10.1016/j.ehj.2003.10.001 · Cited by 37
Self-citation
Cited by
Clinical End Points in Coronary Stent Trials: A Case for Standardized Definitions
Cutlip, D. E., Windecker, S., Mehran, R., Boam, A., Cohen, D. J., van Es, G.-A., Gabriel Steg, P., Morel, M.-A., Mauri, L., Vranckx, P., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.685313 · Cited by 5,497
Anderson, J. L., Adams, C. D., Antman, E. M., Bridges, C. R., Califf, R. M., Casey, D. E., Chavey, W. E., Fesmire, F. M., Hochman, J. S., Levin, T. N., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.181940 · Cited by 1,853
Safety and Efficacy of Sirolimus- and Paclitaxel-Eluting Coronary Stents
Stone, G. W., Moses, J. W., Ellis, S. G., Schofer, J., Dawkins, K. D., Morice, M.-C., Colombo, A., Schampaert, E., Grube, E., Kirtane, A. J., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa067193 · Cited by 1,631
2021 ACC/AHA/SCAI Guideline for Coronary Artery Revascularization
Lawton, J. S., Tamis-Holland, J. E., Bangalore, S., Bates, E. R., Beckie, T. M., Bischoff, J. M., Bittl, J. A., Cohen, M. G., DiMaio, J. M., Don, C. W., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.09.006 · Cited by 1,558
Anderson, J. L., Adams, C. D., Antman, E. M., Bridges, C. R., Califf, R. M., Casey, D. E., Chavey, W. E., Fesmire, F. M., Hochman, J. S., Levin, T. N., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.02.013 · Cited by 1,510
Metadata
- Authors
- Nordmann, A. J., Briel, M., & Bucher, H. C.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-11-13
- Volume
- 27
- Issue
- 23
- Pages
- 2784-2814
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2118606605
- Cited by
- 480
- References
- 34
- FWCI
- 72.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.