A comparison of single-lead atrial pacing with dual-chamber pacing in sick sinus syndrome
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
AIMS: In patients with sick sinus syndrome, bradycardia can be treated with a single-lead pacemaker or a dual-chamber pacemaker. Previous trials have revealed that pacing modes preserving atrio-ventricular synchrony are superior to single-lead ventricular pacing, but it remains unclear if there is any difference between single-lead atrial pacing (AAIR) and dual-chamber pacing (DDDR). METHODS AND RESULTS: We randomly assigned 1415 patients referred for first pacemaker implantation to AAIR (n = 707) or DDDR (n = 708) pacing and followed them for a mean of 5.4 ± 2.6 years. The primary outcome was death from any cause. Secondary outcomes included paroxysmal and chronic atrial fibrillation, stroke, heart failure, and need for pacemaker reoperation. In the AAIR group, 209 patients (29.6%) died during follow-up vs. 193 patients (27.3%) in the DDDR group, hazard ratio (HR) 1.06, 95% confidence interval (CI) 0.88-1.29, P = 0.53. Paroxysmal atrial fibrillation was observed in 201 patients (28.4%) in the AAIR group vs. 163 patients (23.0%) in the DDDR group, HR 1.27, 95% CI 1.03-1.56, P = 0.024. A total of 240 patients underwent one or more pacemaker reoperations during follow-up, 156 (22.1%) in the AAIR group vs. 84 (11.9%) in the DDDR group (HR 1.99, 95% CI 1.53-2.59, P < 0.001). The incidence of chronic atrial fibrillation, stroke, and heart failure did not differ between treatment groups. CONCLUSION: In patients with sick sinus syndrome, there is no statistically significant difference in death from any cause between AAIR pacing and DDDR pacing. AAIR pacing is associated with a higher incidence of paroxysmal atrial fibrillation and a two-fold increased risk of pacemaker reoperation. These findings support the routine use of DDDR pacing in these patients. CLINICAL TRIAL REGISTRATION: URL http://www.clinicaltrials.gov. Unique identifier: NCT00236158.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The DAVID Trial Investigators* (2002) · JAMA · doi:10.1001/jama.288.24.3115 · Cited by 2,056
Sweeney, M. O., Hellkamp, A. S., Ellenbogen, K. A., Greenspon, A. J., Freedman, R. A., Lee, K. L., & Lamas, G. A. (2003) · Circulation · doi:10.1161/01.cir.0000072769.17295.b1 · Cited by 1,773
Baddour, L. M., Epstein, A. E., Erickson, C. C., Knight, B. P., Levison, M. E., Lockhart, P. B., Masoudi, F. A., Okum, E. J., Wilson, W. R., Beerman, L. B., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.192665 · Cited by 1,030 · cited 1×
“Any pacemaker reoperation is associated with a 2% risk of device infection, with a potential need to extract the complete pacemaker system.(24,25) These findings suggest that when a patient with an AAIR pacemaker is referred for a generator replacement or other reoperation, consideration should be given to implanting…”
BackgroundVentricular Pacing or Dual-Chamber Pacing for Sinus-Node Dysfunction
Lamas, G. A., Lee, K. L., Sweeney, M. O., Silverman, R., Leon, A., Yee, R., Marinchak, R. A., Flaker, G., Schron, E., Orav, E. J., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013040 · Cited by 997
Andersen, H. R., Nielsen, J. C., Thomsen, P. E. B., Thuesen, L., Mortensen, P. T., Vesterlund, T., & Pedersen, A. K. (1997) · The Lancet · doi:10.1016/s0140-6736(97)03425-9 · Cited by 841 · cited 2×
“More than a decade ago, a small randomized trial showed better overall survival with AAIR pacing than with single-lead ventricular pacing.(5) Since the current trial was initiated, three large trials comparing single-lead ventricular and dual-chamber pacing in different .”
ResultSelf-citationConnolly, S. J., Kerr, C. R., Gent, M., Roberts, R. S., Yusuf, S., Gillis, A. M., Sami, M. H., Talajic, M., Tang, A. S. L., Klein, G. J., et al. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005113421902 · Cited by 775
Long-term Outcomes in Individuals With Prolonged PR Interval or First-Degree Atrioventricular Block
Cheng, S. (2009) · JAMA · doi:10.1001/jama.2009.888 · Cited by 614
Minimizing Ventricular Pacing to Reduce Atrial Fibrillation in Sinus-Node Disease
Sweeney, M. O., Bank, A. J., Nsah, E., Koullick, M., Zeng, Q. C., Hettrick, D., Sheldon, T., & Lamas, G. A. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa071880 · Cited by 520
Nielsen, J. C., Kristensen, L., Andersen, H. R., Mortensen, P. T., Pedersen, O. L., & Pedersen, A. K. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00757-5 · Cited by 506
Self-citationProspective randomised trial of atrial versus ventricular pacing in sick-sinus syndrome
Andersen, H. R., Thuesen, L., Bagger, J. P., Vesterlund, T., & Thomsen, P. E. B. (1994) · The Lancet · doi:10.1016/s0140-6736(94)90347-6 · Cited by 491
Self-citation
Cited by
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht150 · Cited by 2,809
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab364 · Cited by 2,019
Self-citationAuthors/Task Force Members, Brignole, M., Auricchio, A., Baron-Esquivias, G., Bordachar, P., Boriani, G., Breithardt, O.-A., Cleland, J., Deharo, J.-C., Delgado, V., et al. (2013) · Europace · doi:10.1093/europace/eut206 · Cited by 1,124
Self-citationKusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.044 · Cited by 1,008
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2022) · EP Europace · doi:10.1093/europace/euab232 · Cited by 914
Self-citationKusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000628 · Cited by 603
Pacemaker or Defibrillator Surgery without Interruption of Anticoagulation
Birnie, D. H., Healey, J. S., Wells, G. A., Verma, A., Tang, A. S., Krahn, A. D., Simpson, C. S., Ayala-Paredes, F., Coutu, B., Leiria, T. L. L., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1302946 · Cited by 579
Self-citationWilkoff, B. L., Fauchier, L., Stiles, M. K., Morillo, C. A., Al-Khatib, S. M., Almendral, J., Aguinaga, L., Berger, R. D., Cuesta, A., Daubert, J. P., et al. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2015.11.018 · Cited by 301
Self-citationLinde, C., Bongiorni, M. G., Birgersdotter-Green, U., Curtis, A. B., Deisenhofer, I., Furokawa, T., Gillis, A. M., Haugaa, K. H., Lip, G. Y. H., Van Gelder, I., et al. (2018) · EP Europace · doi:10.1093/europace/euy067 · Cited by 296
Wilkoff, B. L., Fauchier, L., Stiles, M. K., Morillo, C. A., Al-Khatib, S. M., Almendral, J., Aguinaga, L., Berger, R. D., Cuesta, A., Daubert, J. P., et al. (2016) · Europace · doi:10.1093/europace/euv411 · Cited by 243
“Use of the AAIR pacing mode with exceedingly long atrioventricular conduction times can lead to “AAIR pacemaker syndrome” and actually increases the risk of AF compared with the DDDR mode, as was shown in the Danish Multicenter Randomized Trial on Single Lead Atrial versus DualChamber Pacing in Sick Sinus Syndrome (DA…”
ResultSelf-citationSinus Node and Atrial Arrhythmias
John, R. M., & Kumar, S. (2016) · Circulation · doi:10.1161/circulationaha.116.018011 · Cited by 215
“A characteristic feature, however, is the development of supraventricular arrhythmias, of which AF is the most common.(2,17,18)”
BackgroundInfluentialSticherling, C., Marin, F., Birnie, D., Boriani, G., Calkins, H., Dan, G.-A., Gulizia, M., Halvorsen, S., Hindricks, G., Kuck, K.-H., et al. (2015) · EP Europace · doi:10.1093/europace/euv190 · Cited by 197
Arrhythmias in Patients ≥80 Years of Age
Curtis, A. B., Karki, R., Hattoum, A., & Sharma, U. C. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.03.019 · Cited by 169
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2018.10.037 · Cited by 131
Ng Kam Chuen, M. J., Kirkfeldt, R. E., Andersen, H. R., & Nielsen, J. C. (2014) · Heart · doi:10.1136/heartjnl-2013-304976 · Cited by 27
Self-citation
Metadata
- Authors
- Nielsen, J. C., Thomsen, P. E. B., Hojberg, S., Moller, M., Vesterlund, T., Dalsgaard, D., Mortensen, L. S., Nielsen, T., Asklund, M., Friis, E. V., Christensen, P. D., Simonsen, E. H., Eriksen, U. H., Jensen, G. V. H., Svendsen, J. H., Toff, W. D., Healey, J. S., Andersen, H. R., & on behalf of the DANPACE Investigators
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-02-07
- Volume
- 32
- Issue
- 6
- Pages
- 686-696
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2132743609
- Cited by
- 297
- References
- 26
- FWCI
- 16.41
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.