A randomized trial of long-term remote monitoring of pacemaker recipients (The COMPAS trial)
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
AIMS: Professional practice guidelines recommend that pacemaker recipients be followed regularly. However, the majority of scheduled ambulatory visits is unproductive and imposes a heavy burden on the health-care system. METHODS AND RESULTS: The COMPAS randomized, multicentre, non-inferiority trial examined the safety of long-term remote monitoring of pacemakers. Between December 2005 and January 2008, 538 patients were randomly assigned to remote monitoring follow-up (active group) vs. standard care (control group). The primary objective was to confirm that the proportion of patients who experienced at least one major adverse event (MAE), including all-cause death and hospitalizations for device-related or cardiovascular adverse events, was not >7% higher in the active than in the control group. MAE-free survivals and quality of life were compared in both groups. The characteristics of the study groups were similar. Over a follow-up of 18.3 months, 17.3% of patients in the active and 19.1% in the control group experienced at least one MAE (P < 0.01 for non-inferiority). Hospitalizations for atrial arrhythmias (6 vs. 18) and strokes (2 vs. 8) were fewer (P < 0.05), and the number of interim ambulatory visits was 56% lower (P < 0.001) in the active than the control group. Changes in pacemaker programming or drug regimens were made in 62% of visits in the active vs. 29% in the control group (P < 0.001). Quality of life remained unchanged in both groups. CONCLUSION: Remote monitoring was a safe alternative to conventional care and significantly lowered the number of ambulatory visits during long-term follow-up of permanently paced patients. ClinicalTrials.gov identifier: NCT00989326.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures


Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In the similar, more recent Chronicle Offers Management to Patients with Advanced Signs and Symptoms of Heart Failure (COMPAS) trial, both ambulatory visits and hospitalizations were fewer in those randomly assigned to remote follow-up.58”
From Managing with pacemakers and implantable cardioverter defibrillators (2013) · cites this paper as [58]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1992) · PubMed · Cited by 33,716
The MOS 36-ltem Short-Form Health Survey (SF-36): I. Conceptual Framework and Item Selection
Ware, J. E., & Sherbourne, C. D. (1992) · Medical Care · doi:10.1097/00005650-199206000-00002 · Cited by 30,033
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
Writing Committee Members, Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., et al. (2008) · Circulation · doi:10.1161/circualtionaha.108.189742 · Cited by 1,774
THE MOS 36- ITEM SHORT FORM HEALTH SURVEY (SF- 36) CONCEPTUAL FRAMEWORK AND ITEM SELECTION
J.E.Jr., W., & Sherburne, C. D. (1992) · Cited by 1,586
Authors/Task Force Members, Vardas, P. E., Auricchio, A., Blanc, J.-J., Daubert, J.-C., Drexler, H., Ector, H., Gasparini, M., Linde, C., Morgado, F. B., et al. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm305 · Cited by 902
Self-citationCleland, J. G. F., Louis, A. A., Rigby, A. S., Janssens, U., & Balk, A. H. M. M. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.01.050 · Cited by 700
Varma, N., Epstein, A. E., Irimpen, A., Schweikert, R., & Love, C. (2010) · Circulation · doi:10.1161/circulationaha.110.937409 · Cited by 594
The CONNECT (Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision) Trial
Crossley, G. H., Boyle, A., Vitense, H., Chang, Y., & Mead, R. H. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.12.012 · Cited by 526
Single-Chamber versus Dual-Chamber Pacing for High-Grade Atrioventricular Block
Toff, W. D., Camm, A. J., & Skehan, J. D. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa042283 · Cited by 384
Cited by
Items 301–346 of 346
OBSOLETE: Remote Monitoring of Cardiac Implantable Electronic Devices
Parkash, R. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-801238-3.99792-7
Telemonitorering gir nye roller for både pasient og sjukepleiar
Moen, E. K. F., Fadnes, D. J., & Norekvål, T. M. (2017) · Sykepleien Forskning · doi:10.4220/sykepleiens.2017.64786
“Desse parametrane kan ein ha god oversikt over via TM, og dermed kan ein spare pasienten, pårørande, helsevesenet og samfunnet for reise til sjukehuskontrollar (1-2).”
BackgroundCardiologie connectée : état des lieux et perspectives
Junior, J. B. S. D. C., Martin, A., & Metz, D. (2018) · Archives des Maladies du Coeur et des Vaisseaux - Pratique · doi:10.1016/j.amcp.2018.04.002
Telemonitoring and Contemporary Outpatient Management of Patients with Heart Failure: Is it Time?
Alexy, T., & Francis, G. S. (2018) · Cardiologia Hungarica · doi:10.26430/chungarica.2018.48.2.100
“COMPAS (56) HRV, arrhythmias Reduced ambulatory clinic visits”
BackgroundFollow-Up of Cardiac Implantable Electronic Devices—Remote Monitoring and in Person
Varma, N., & Ricci, R. P. (2016) · Elsevier eBooks · doi:10.1016/b978-0-323-37804-8.00040-7
林, 高. (2019) · Advances in Clinical Medicine · doi:10.12677/acm.2019.94077
“01)。在再住院率、卒中发生率等指标上远程监测组同 样显著低于对照组。两组之间在生活质量方面没有显著差异[27]。由此可知,对于起搏器植入术后的患者 来说远程监测能够安全有效地替代常规门诊随访。Comorettod 等[28]则主要对起搏器植入术后老年患者的 生活质量进行研究,其评估指标为健康相关生活质量(health-related quality of life, HRQoL)。结果显示,起”
Brunello, L. F. S., de Figueiredo, G. A., & Mulinari, L. (2019) · Journal of Cardiac Arrhythmias · doi:10.24207/jac.v32i1.003_pt
Electrocardiographic characteristics in detecting pacemaker battery depletion
Jalloul, Y., & Refaat, M. M. (2019) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13829
Occurrence of Subclinical Atrial Fibrillation in the Follow-up of Patients with Cardiac Pacemakers
Brunello, L. F. S., de Figueiredo, G. A., & Mulinari, L. (2019) · Journal of Cardiac Arrhythmias · doi:10.24207/jac.v32i1.003_in
Obstructive Sleep Apnoea Syndrome and Arrhythmia: Results of 10 Years’ Experience
Cipolletta, L., Urbinati, A., Matassini, M. V., Francesca, M., Gasparini, S., & Capucci, A. (2020) · Springer eBooks · doi:10.1007/978-3-030-33832-9_17
Wired Heart Cyborgs and the Materiality of Everyday Life
Oudshoorn, N. (2020) · Springer eBooks · doi:10.1007/978-981-15-2529-2_5
The role of remote monitoring for cardiac implantable electronic devices
Gold, M. R., John, L., & Ishida, Y. (2019) · International Journal of Heart Rhythm · doi:10.4103/ijhr.ijhr_4_19
Transmission Rate of Remote Monitoring and Mortality in Patients With Pacemaker
Goto, T., Mori, K., Nakayama, T., Yamamoto, J., Shintani, Y., Nakasuka, K., Wakami, K., Fukuta, H., Seo, Y., & Ohte, N. (2020) · Circulation Reports · doi:10.1253/circrep.cr-20-0071
Telemonitoring applications in cardiology
Milner, J., & Gonçalves, L. M. M. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-818950-4.00002-1 · Cited by 1
Remote Programming of CIED Based On 5G Cloud Follow-up AppPreprint
Cui, C.-Y., Tong, L., Li, J., Liu, H., & Cai, L. (2022) · doi:10.22541/au.164922847.76115117/v1
Remote Monitoring of Cardiovascular Implantable Electronic Devices
Plourde, B., & Parkash, R. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-809657-4.99792-8
Portugal, G., Cunha, P. S., Valente, B. T., Feliciano, J., Lousinha, A., Alves, S., Braz, M., Pimenta, R., Delgado, A. S., Oliveira, M., et al. (2017) · Revista Portuguesa de Cardiologia (English Edition) · doi:10.1016/j.repce.2016.08.007 · Cited by 1
Copyright and licensing of E-journals: Perspective from E-journals in J-STAGE
耕平, 石., & 英夫, 岡. (2017) · Japanese Journal of Electrocardiology · doi:10.5105/jse.37.198
Rosa, S. A., Cunha, P. S., Lousinha, A., Valente, B. T., Delgado, A. S., Pimenta, R., Brás, M., Cruz, M. C., Portugal, G., Monteiro, A. V., et al. (2019) · Revista Portuguesa de Cardiologia (English Edition) · doi:10.1016/j.repce.2018.05.013
Telecardiología. De la prevención primaria a la secundaria
Carrillo-Alemán, L., Roy, I., Brocal, M. H., & Salinas, G. L. A. (2022) · REC CardioClinics · doi:10.1016/j.rccl.2022.06.005
Télésurveillance en rythmologie : apports et limites
Klein, C., & Guédon-Moreau, L. (2023) · Archives des Maladies du Coeur et des Vaisseaux - Pratique · doi:10.1016/j.amcp.2023.01.009
Reducing the Global Carbon Footprint of Cardiac Arrhythmia Management
Sliwa, K. S., & Viljoen, C. A. (2023) · JACC Advances · doi:10.1016/j.jacadv.2023.100351
The role of remote monitoring in detecting of the defibrillation lead dislocation: case report
Amiraslanov, A. Y., Викторовна, Д. Е., & Artyukhina, Е. А. (2023) · Сибирский журнал клинической и экспериментальной медицины · doi:10.29001/2073-8552-2023-38-2-235-240
Seo, J., Alhuarrat, M. A. D., Krishnan, S., Saralidze, T., Lim, H., Chen, B., Flomenbaum, D. E., Naser, A., Kharawala, A., Apple, S. J., et al. (2023) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.14883
“3,4,7,9 12 RM also reduces health-care workload 13 and cost 2,5,14 while maintaining a high quality of life and satisfaction of patients after device implantation.”
BackgroundThe Dropout from Remote Monitoring in CIEDs Patients
Kida, H., Kikuchi, Y., Otani, S., Aoki, R., Tamaki, S., Okada, K., Sato, N., Uenoyama, M., Kawasaki, M., Watanabe, T., et al. (2023) · Japanese Journal of Electrocardiology · doi:10.5105/jse.43.254
William, Y., Tarigan, T., Chen, J., Ismail, M. T., & Hariawan, H. (2024) · F1000Research · doi:10.12688/f1000research.146779.1 · Cited by 1
Sheahen, B., O’Hagan, E. T., Cho, K. K., Shaw, T. J., Lee, A., Lal, S., Sverdlov, A. L., & Chow, C. K. (2024) · doi:10.2196/preprints.67758
Remote Monitoring and Remote Programming of Cardiac Implantable Electronic Devices
Varma, N. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15734-9.00025-x
Duncker, D., Hillmann, H. A. K., & Müller‐Leisse, J. (2025) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-024-01062-6
Remote patient monitoring in rehabilitation programs: challenges and prospects
Akinshina, S. V., & Borisevich, O. O. (2025) · Реабилитология. · doi:10.17749/2949-5873/rehabil.2024.31
植込み型デバイス委員会社会問題対策委員会 植込み型心臓不整脈デバイスの遠隔モニタリングに関する日本不整脈心電学会(JHRS)ステートメント
Watanabe, E., Nishii, N., Maeda, A., Sakai, Y., Fujiu, K., Suzuki, M., Kato, R., Abe, H., Noda, T., Tada, H., et al. (2025) · Japanese Journal of Electrocardiology · doi:10.5105/jse.45.33
William, Y., Tarigan, T., Chen, J., Ismail, M. T., & Hariawan, H. (2025) · F1000Research · doi:10.12688/f1000research.146779.3
Peshkov, S. A., Титов, Д. С., Povarov, V. O., & Yаkushin, S. S. (2025) · Journal of Arrhythmology · doi:10.35336/va-1477
Kelly, S. E., Clifford, T., Coyle, D., Martin, J., Welch, V., Skidmore, B., Birnie, D., Parkash, R., Tang, A. S. L., & Wells, G. A. (2020) · Figshare · doi:10.6084/m9.figshare.12579315
Kelly, S. E., Clifford, T., Coyle, D., Martin, J., Welch, V., Skidmore, B., Birnie, D., Parkash, R., Tang, A. S. L., & Wells, G. A. (2020) · Figshare · doi:10.6084/m9.figshare.12579312
Kelly, S. E., Clifford, T., Coyle, D., Martin, J., Welch, V., Skidmore, B., Birnie, D., Parkash, R., Tang, A. S. L., & Wells, G. A. (2020) · Figshare · doi:10.6084/m9.figshare.12579306
Kelly, S. E., Clifford, T., Coyle, D., Martin, J., Welch, V., Skidmore, B., Birnie, D., Parkash, R., Tang, A. S. L., & Wells, G. A. (2020) · Figshare · doi:10.6084/m9.figshare.12579309
Peshkov, S. A., & Povarov, V. O. (2026) · The Clinician · doi:10.17650/1818-8338-2025-19-4-k747
Simulations numériques standardisées de dispositifs de stimulation électrique cardiaque
Pannetier, V. (2024) · theses.fr (ABES) · doi:10.70675/e08490cazbcdcz4cd9z8240z0b83af0a6cdd
Tan, E. S. J., Ying, L. J., Tiong, Y. W., & Kojodjojo, P. (2026) · Indian Pacing and Electrophysiology Journal · doi:10.1016/j.ipej.2026.06.004
“The safety and ability of RM to reduce in-clinic visits and provide timely detection of actionable events have been demonstrated in multiple studies for both pacemakers and ICDs [5,9 – 11].”
Cardiac Implantable Electronic Devices Remote Programming
Ploux, S., Strik, M., Varma, N., Thiyagarajah, A., Haı̈ssaguerre, M., Bénali, K., & Bordachar, P. (2026) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.125.014786
Parkash, R., Sears, S. F., Philippon, F., Sterns, L. D., Kelly, S., O’Neil, K., Thavorn, K., Wells, G. A., & TANG, A. S. L. (2026) · CJC Open · doi:10.1016/j.cjco.2026.08.003 · Cited by 1
Watanabe, E., Nishii, N., Maeda, A., 堺美郎, Fujiu, K., Suzuki, M., Kato, R., Abe, H., Noda, T., Tada, H., et al. (2026) · Journal of Arrhythmia · doi:10.1002/joa3.70437 · Cited by 1
“IIa B-R Consider extending the in-person consultation interval to up to every 24 months in stable pacemaker patients connected to RM capable of continuous daily data transmission [8, 9, 68] (For the sake of health insurance coverage, in-person consultations are recommended once a year).”
Metadata
- Authors
- Mabo, P., Victor, F., Bazin, P., Ahres, S., Babuty, D., Da Costa, A., Binet, D., & Daubert, J.-C.
- Affiliations
- Inserm (FR)
- Saint Laurent Polyclinique (FR)
- Centre Hospitalier de Redon (FR)
- Centre Hospitalier Universitaire de Tours (FR)
- Corresponding author
- Mabo, Philippe
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-11-29
- Volume
- 33
- Issue
- 9
- Pages
- 1105-1111
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- PMC
- PMC3341630
- OpenAlex
- W2112916640
- Semantic Scholar
- 7b0357a05a4d8882e3f039eb74ac19e6317c2e1c
- Cited by
- 347
- References
- 19
- Citations by year
- 2026: 7 · 2025: 18 · 2024: 12 · 2023: 28 · 2022: 16 · 2021: 30 · 2020: 36 · 2019: 27 · 2018: 20 · 2017: 28 · 2016: 17 · 2015: 29 · 2014: 22 · 2013: 38 · 2012: 19
- FWCI
- 17.31
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc
- Locations
- European Heart Journal (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- HAL (submittedVersion)
- Funders
- Commercializations Promotion Agency for R and D Outcomes
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Telemedicine and Telehealth Implementation
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Health and Mental Health
- Keywords
- remote monitoring, cardiac pacemaker, permanent cardiac pacing, major adverse events, non-inferiority, hospitalization, atrial arrhythmias, stroke, quality of life, pacemaker programming, device safety
- MeSH terms
- Aged, Aged, 80 and over, Arrhythmias, Cardiac, Cardiac Pacing, Artificial, Female, Follow-Up Studies, Humans, Male, Pacemaker, Artificial, Postoperative Care, Treatment Outcome, Remote Consultation, Kaplan-Meier Estimate
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.