Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 87 of the 88 references it cites were found in a registry or an index.

Monitoring capabilities of cardiac rhythm management devices

Abstract

Since the advent of the first generation pacemakers, solely providing rate support, we have witnessed a technological outburst in the type and complexity of implantable devices. The introduction of implantable cardioverter defibrillators and later of cardiac resynchronization therapy devices enriched our therapeutic arsenal for the management of patients with heart failure and/or high risk of sudden cardiac death. In addition, during the last decade, newer generation cardiac rhythm management devices (CRMs) have been capable to provide a continuously expanding pool of diagnostic information derived by novel monitoring capabilities. Although at present the clinical role of this information is undervalued, it is evident that the clinical exploitation of data derived by CRMs may transform the standards of care for our patients by providing timely applied individualized diagnosis and treatment. In this context, even in the absence of solid data supporting the use of this information in everyday clinical practice, improving our familiarity with currently available monitoring algorithms is a prerequisite for the electrophysiologist who keeps in pace with the rapidly evolving technologies of CRMs and is prepared for their future role on clinical practice.

Overview

Integrity signals

Registry

Crossref · 10.1093/europace/eup317

Cites

87 of 87 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 4

  1. 2004, 45, 277
  2. 2007, Pacing and clinical electrophysiology : PACE, 30, S2
  3. 2006, Circulation, 114, II-749
  4. 2006, 33, 241

Cited by

See all 5

Metadata

Authors
Andrikopoulos, G., Tzeis, S., Theodorakis, G., & Vardas, P.
Affiliations
  • Henry Dunant Hospital (GR)
  • Deutsches Herzzentrum München (DE)
  • University Hospital of Heraklion (GR)
Corresponding author
Vardas, P.
Venue
Europace
Published
2009-10-29
Volume
12
Issue
1
Pages
17-23
ISSN
  • 1099-5129 (ISSN-L)
  • 1532-2092
OpenAlex
W2146249065
Cited by
5
References
88
Citations by year
2018: 1 · 2017: 2 · 2014: 2
FWCI
0.00
Type
journal article
Language
en
Open access
closed
Locations
  • EP Europace (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
Keywords
cardiac rhythm management devices, implantable cardioverter-defibrillator, cardiac resynchronization therapy, cardiac pacemaker, remote monitoring, heart failure, sudden cardiac death, electrophysiology
MeSH terms
Algorithms, Diagnosis, Computer-Assisted, Equipment Design, Pacemaker, Artificial, Therapy, Computer-Assisted, Electrocardiography, Ambulatory, Systems Integration, Equipment Failure Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.