ESC-EURObservational Research Programme: the Atrial Fibrillation Ablation Pilot Study, conducted by the European Heart Rhythm Association
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
AIMS: The Atrial Fibrillation Ablation Pilot Study is a prospective, multinational registry conducted by the European Heart Rhythm Association of the European Society of Cardiology that has been designed to describe the clinical epidemiology of patients undergoing an atrial fibrillation (AFib) ablation procedure, and the diagnostic/therapeutic processes applied in these patients across Europe. We present the results of the short-term (in-hospital) analysis. METHODS AND RESULTS: A total of 72 centres in 10 European countries were asked to enrol 20 consecutive patients scheduled for a first AFib ablation procedure. Between October 2010 and May 2011, 1410 patients were included, of which 1391 underwent an AFib ablation (98.7%). The median age was 60 years [inter-quartile range (IQR) 52-66], and 28% were females. Two-thirds presented paroxysmal AFib and 38% lone AFib. Symptoms were present in 86%. The indications for ablation were mostly symptomatic AFib, but in over a third of patients there was also a desire for a drug-free lifestyle and the maintenance of sinus rhythm. Pulmonary vein isolation was attempted in 98.4% of patients, the roof line in 21.3% and the mitral isthmus line in 12.8%. Complex-fractionated atrial electrograms were targeted in 17.9% and the ganglionated plexi in 3.3%. Complications occurred in 7.7%, of which 1.7% was major (i.e. cardiac perforation, myocardial infraction, endocarditis, cardiac arrest, stroke, hemothorax, pneumothorax, and sepsis). The median duration of hospitalization was 3 days (IQR 2-4). At discharge, 91.4% of patients were in sinus rhythm, 88.3% of patients were given vitamin K antagonists, and 67% antiarrhythmic medication. There was one death after the ablation procedure. CONCLUSION: The AFib Ablation Pilot Study provides crucial information on AF ablation in clinical practice across Europe. These data are relevant for further improvement of the management strategies of patients suffering from atrial fibrillation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Natale, A., Packer, D., et al. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.859116 · Cited by 2,852
Stewart, S., Hart, C. L., Hole, D. J., & McMurray, J. J. V. (2002) · The American Journal of Medicine · doi:10.1016/s0002-9343(02)01236-6 · Cited by 1,562
Atrial Fibrillation: A Major Contributor to Stroke in the Elderly: The Framingham Study
Wolf, P. A. (1987) · Archives of Internal Medicine · doi:10.1001/archinte.1987.00370090041008 · Cited by 1,108
Pappone, C., Rosanio, S., Augello, G., Gallus, G., Vicedomini, G., Mazzone, P., Gulletta, S., Gugliotta, F., Pappone, A., Santinelli, V., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00577-1 · Cited by 781
Atrial Tachycardia After Circumferential Pulmonary Vein Ablation of Atrial Fibrillation
Chae, S., Oral, H., Good, E., Dey, S., Wimmer, A., Crawford, T., Wells, D., Sarrazin, J.-F., Chalfoun, N., Kuhne, M., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.07.044 · Cited by 355
Ouyang, F., Ernst, S., Vogtmann, T., Goya, M., Volkmer, M., Schaumann, A., Bänsch, D., Antz, M., & Kuck, K.-H. (2002) · Circulation · doi:10.1161/01.cir.0000015077.12680.2e · Cited by 212
Peri-mitral atrial flutter in patients with atrial fibrillation ablation
Matsuo, S., Wright, M., Knecht, S., Nault, I., Lellouche, N., Lim, K.-T., Arantes, L., O'Neill, M. D., Hocini, M., Jaïs, P., et al. (2010) · Heart Rhythm · doi:10.1016/j.hrthm.2009.09.067 · Cited by 153
Cited by
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström-Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P. E., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 9,971
Self-citationJanuary, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000041 · Cited by 7,115
2012 focused update of the ESC Guidelines for the management of atrial fibrillation
Authors/Task Force Members, Camm, A. J., Lip, G. Y. H., De Caterina, R., Savelieva, I., Atar, D., Hohnloser, S. H., Hindricks, G., Kirchhof, P., ESC Committee for Practice Guidelines (CPG), et al. (2012) · EP Europace · doi:10.1093/europace/eus305 · Cited by 3,822
Self-citation2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.03.022 · Cited by 2,955
2012 focused update of the ESC Guidelines for the management of atrial fibrillation
Authors/Task Force Members, Camm, A. J., Lip, G. Y. H., De Caterina, R., Savelieva, I., Atar, D., Hohnloser, S. H., Hindricks, G., Kirchhof, P., ESC Committee for Practice Guidelines (CPG), et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs253 · Cited by 2,899
Self-citationDi Biase, L., Burkhardt, J. D., Santangeli, P., Mohanty, P., Sanchez, J. E., Horton, R., Gallinghouse, G. J., Themistoclakis, S., Rossillo, A., Lakkireddy, D., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.006426 · Cited by 485
Mont, L., Bisbal, F., Hernández-Madrid, A., Pérez-Castellano, N., Viñolas, X., Arenal, A., Arribas, F., Fernández-Lozano, I., Bodegas, A., Cobos, A., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht457 · Cited by 394
“In the present trial, CA showed an acceptable safety profile, comparable with the latest international registries.(17,25) Remarkably, neither deathsnor strokesoccurred.”
ResultSelf-citationLinde, C., Bongiorni, M. G., Birgersdotter-Green, U., Curtis, A. B., Deisenhofer, I., Furokawa, T., Gillis, A. M., Haugaa, K. H., Lip, G. Y. H., Van Gelder, I., et al. (2018) · EP Europace · doi:10.1093/europace/euy067 · Cited by 296
Wynn, G. J., Todd, D. M., Webber, M., Bonnett, L., McShane, J., Kirchhof, P., & Gupta, D. (2014) · Europace · doi:10.1093/europace/eut395 · Cited by 254
Arbelo, E., Brugada, J., Lundqvist, C. B., Laroche, C., Kautzner, J., Pokushalov, E., Raatikainen, P., Efremidis, M., Hindricks, G., Barrera, A., et al. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehw564 · Cited by 232
Self-citationArbelo, E., Brugada, J., Hindricks, G., Maggioni, A. P., Tavazzi, L., Vardas, P., Laroche, C., Anselme, F., Inama, G., Jais, P., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu001 · Cited by 212
Self-citationHakalahti, A., Biancari, F., Nielsen, J. C., & Raatikainen, M. J. P. (2015) · Europace · doi:10.1093/europace/euu376 · Cited by 191
Nielsen, J. C., Lin, Y.-J., de Oliveira Figueiredo, M. J., Sepehri Shamloo, A., Alfie, A., Boveda, S., Dagres, N., Di Toro, D., Eckhardt, L. L., Ellenbogen, K., et al. (2020) · EP Europace · doi:10.1093/europace/euaa065 · Cited by 98
Self-citationAnselmino, M., Matta, M., D'ascenzo, F., Pappone, C., Santinelli, V., Bunch, T. J., Neumann, T., Schilling, R. J., Hunter, R. J., Noelker, G., et al. (2015) · Europace · doi:10.1093/europace/euv214 · Cited by 88
“With the inclusion of redo procedures, the long-term SR maintenance rate improved to 66%: this result is comparable with long-term outcomes reported in general AFCA populations, which typically include patients with both their first and redo ablations.(10,30,31) The relatively large proportion (37%) of patients requir…”
ResultThe first Latin American Catheter Ablation Registry
Keegan, R., Aguinaga, L., Fenelon, G., Uribe, W., Rodriguez Diez, G., Scanavacca, M., Patete, M., Carhuaz, R. Z., Labadet, C., De Zuloaga, C., et al. (2015) · EP Europace · doi:10.1093/europace/euu322 · Cited by 52
“On the other hand, the rate of complications in atrial fibrillation ablation was higher than expected(8) but similar to the European AFib ablation registry published recently.(9,10) This finding could be associated with the low numbers of procedures performed yearly for this arrhythmia.”
Result
Metadata
- Authors
- Arbelo, E., Brugada, J., Hindricks, G., Maggioni, A., Tavazzi, L., Vardas, P., Anselme, F., Inama, G., Jais, P., Kalarus, Z., Kautzner, J., Lewalter, T., Mairesse, G., Perez-Villacastin, J., Riahi, S., Taborsky, M., Theodorakis, G., Trines, S., & on behalf of the Atrial Fibrillation Ablation Pilot Study Investigators
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-05-24
- Volume
- 14
- Issue
- 8
- Pages
- 1094-1103
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2167871484
- Cited by
- 125
- References
- 7
- FWCI
- 13.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.