Role of extended external loop recorders for the diagnosis of unexplained syncope, pre-syncope, and sustained palpitations
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
AIMS: To assess the diagnostic yield of new external loop recorders (ELRs) in patients with history of syncope, pre-syncope, and sustained palpitations. METHODS AND RESULTS: Since 2005, we have established a registry including patients who consecutively received ELR monitoring for unexplained syncope or pre-syncope/palpitations. The registry included 307 patients (61% females, age 58 ± 19 years, range 8-94 years) monitored by high-capacity memory ELR of two subsequent generations: SpiderFlash-A(®) (SFA(®), Sorin CRM), storing two-lead electrocardiogram (ECG) patient-activated recordings by loop-recording technique (191 patients, 54 patients with syncope, years 2005-09), and SpiderFlash-T(®) (SFT(®)), adding auto-trigger detection for pauses, bradycardia, and supraventricular/ventricular arrhythmias (116 patients, 38 patients with syncope, years 2009-12). All the patients previously underwent routine workup for syncope or palpitation, including one or more 24 h Holter, not conclusive for diagnosis. Mean monitoring duration was 24.1 ± 8.9 days. Among 215 patients with palpitations, a conclusive diagnosis was obtained in 184 patients (86% diagnostic yield for palpitation). Among 92 patients with syncope, a conclusive diagnosis was obtained in 16 patients (17% clinical diagnostic yield for syncope), with recording during syncope of significant arrhythmias in 9 patients, and sinus rhythm in 7 patients. Furthermore, asymptomatic arrhythmias were de novo detected in 12 patients (13%), mainly by auto-trigger detection, suggesting an arrhythmic origin of the syncope. CONCLUSIONS: The diagnostic yield of ELR in patients with syncope, pre-syncope, or palpitation of unknown origin after routine workup was similar to implantable loop recorder (ILR) within the same timeframe, therefore, ELR could be considered for patients candidate for long-term ECG monitoring, stepwise before ILR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Developed in collaboration with, European Heart Rhythm Association (EHRA), Heart Failure Association (HFA), and Heart Rhythm Society (HRS), societies, E. B. T. F., European Society of Emergency Medicine (EuSEM), European Federation of Internal Medicine (EFIM), European Union Geriatric Medicine Society (EUGMS), American Geriatrics Society (AGS), European Neurological Society (ENS), et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp298 · Cited by 2,040
Brignole, M., Sutton, R., Menozzi, C., Garcia-Civera, R., Moya, A., Wieling, W., Andresen, D., Benditt, D. G., & Vardas, P. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi842 · Cited by 376
Indications for the use of diagnostic implantable and external ECG loop recorders
Task Force members, Brignole, M., Vardas, P., Hoffman, E., Huikuri, H., Moya, A., Ricci, R., Sulke, N., Wieling, W., EHRA Scientific Documents Committee, et al. (2009) · Europace · doi:10.1093/europace/eup097 · Cited by 362 · cited 2×
“Thus, current indications for ELR are limited to patients with a high probability of recurrent events.(2,4) However, technological advances such as auto-trigger capability and mobile cardiac outpatient telemetry are now showing promising results.”
BackgroundBloch Thomsen, P. E., Jons, C., Raatikainen, M. J. P., Moerch Joergensen, R., Hartikainen, J., Virtanen, V., Boland, J., Anttonen, O., Gang, U. J., Hoest, N., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.902148 · Cited by 285
Incidence of atrial fibrillation detected by implantable loop recorders in unexplained stroke
Cotter, P. E., Martin, P. J., Ring, L., Warburton, E. A., Belham, M., & Pugh, P. J. (2013) · Neurology · doi:10.1212/wnl.0b013e31828f1828 · Cited by 254
Edvardsson, N., Frykman, V., van Mechelen, R., Mitro, P., Mohii-Oskarsson, A., Pasquie, J.-L., Ramanna, H., Schwertfeger, F., Ventura, R., Voulgaraki, D., et al. (2011) · Europace · doi:10.1093/europace/euq418 · Cited by 250 · cited 1×
“The recurrence rate for syncope was similar to that recently reported in the PICTUREregistry includingpatientswithunexplained syncope studied by ILR (19% at 3 months).(9) Thus, extended ELR and ILR (both with auto-trigger capability) had similar diagnostic yields, when considering the same time interval.”
ResultSivakumaran, S., Krahn, A. D., Klein, G. J., Finan, J., Yee, R., Renner, S., & Skanes, A. C. (2003) · The American Journal of Medicine · doi:10.1016/s0002-9343(03)00233-x · Cited by 160
Recurrent Unexplained Palpitations (RUP) Study
Giada, F., Gulizia, M., Francese, M., Croci, F., Santangelo, L., Santomauro, M., Occhetta, E., Menozzi, C., & Raviele, A. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.02.036 · Cited by 158 · cited 1×
“In sustained palpitations, the indication for ELR is more clearly established, since several studies showed that 50–75% of sustained palpitations recurred within 1 month.(5,18) However, most available ELR have technical limitations, due to relatively low-memory capacity and lack of auto-trigger function.”
BackgroundRaviele, A., Giada, F., Bergfeldt, L., Blanc, J. J., Blomstrom-Lundqvist, C., Mont, L., Morgan, J. M., Raatikainen, M. J. P., Steinbeck, G., Viskin, S., et al. (2011) · Europace · doi:10.1093/europace/eur130 · Cited by 149
SCHUCHERT, A., MAAS, R., KRETZSCHMAR, C., BEHRENS, G., KRATZMANN, I., & MEINERTZ, T. (2003) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2003.t01-1-00277.x · Cited by 62
Rockx, M. A., Hoch, J. S., Klein, G. J., Yee, R., Skanes, A. C., Gula, L. J., & Krahn, A. D. (2005) · American Heart Journal · doi:10.1016/j.ahj.2005.08.003 · Cited by 60
Stepwise Evaluation of Unexplained Syncope in a Large Ambulatory Population
IGLESIAS, J. F., GRAF, D., FORCLAZ, A., SCHLAEPFER, J., FROMER, M., & PRUVOT, E. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2008.02291.x · Cited by 37
Research works printed but not linked: 16
- 2006, Europace, 8, 746, 10.1093/europace/eul108 · DOI · Paper page
- 2003, Circulation, 108, 871
- 2010, Europace, 12, 1360, 10.1093/europace/euq350 · DOI · Paper page
- 2013, Europace, 15, 122, 10.1093/europace/eus264 · DOI
- 2013, Progress in cardiovascular diseases, 55, 410, 10.1016/j.pcad.2012.11.009 · DOI
- 2010, Europace, 12, 1475, 10.1093/europace/euq302 · DOI
- Parry, 2010, Heart, 96, 1611, 10.1136/hrt.2010.193417 · DOI
- Muller, 2009, Journal of Telemedicine and Telecare, 15, 391, 10.1258/jtt.2009.090402 · DOI
- 2013, Journal of the neurological sciences, 324, 57, 10.1016/j.jns.2012.10.001 · DOI
- 2011, 8, S161
- Dion, 2010, Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 28, 101, 10.1007/s10840-010-9485-5 · DOI · Paper page
- Gula, 2004, American heart journal, 147, 644, 10.1016/j.ahj.2003.10.036 · DOI
- Gula, 2009, Pacing and clinical electrophysiology : PACE, 32, 466, 10.1111/j.1540-8159.2009.02306.x · DOI
- Albright, 2011, 2011, 5625
- 2012, Europace, 14, 402, 10.1093/europace/eur343 · DOI · Paper page
- Hoch, 2006, BMC health services research [electronic resource], 6, 68, 10.1186/1472-6963-6-68 · DOI · Paper page
Cited by
Steinberg, J. S., Varma, N., Cygankiewicz, I., Aziz, P., Balsam, P., Baranchuk, A., Cantillon, D. J., Dilaveris, P., Dubner, S. J., El-Sherif, N., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.03.038 · Cited by 303
Self-citationPiccini, J. P., Simon, D. N., Steinberg, B. A., Thomas, L., Allen, L. A., Fonarow, G. C., Gersh, B., Hylek, E., Kowey, P. R., Reiffel, J. A., et al. (2016) · JAMA Cardiology · doi:10.1001/jamacardio.2016.0529 · Cited by 273
Portable out-of-hospital electrocardiography: A review of current technologies
Bansal, A., & Joshi, R. (2018) · Journal of Arrhythmia · doi:10.1002/joa3.12035 · Cited by 174
Locati, E. T., Moya, A., Oliveira, M., Tanner, H., Willems, R., Lunati, M., & Brignole, M. (2016) · Europace · doi:10.1093/europace/euv311 · Cited by 95
Self-citationSciaraffia, E., Chen, J., Hocini, M., Larsen, T. B., Potpara, T., & Blomstrom-Lundqvist, C. (2014) · Europace · doi:10.1093/europace/euu222 · Cited by 33
Metadata
- Authors
- Locati, E. T., Vecchi, A. M., Vargiu, S., Cattafi, G., & Lunati, M.
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-10-24
- Volume
- 16
- Issue
- 6
- Pages
- 914-922
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2022183225
- Cited by
- 53
- References
- 12
- FWCI
- 4.49
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.