The Benefit of a Remotely Monitored Implantable Loop Recorder as a First Line Investigation in Unexplained Syncope: The EaSyAS II Trial
Open accessAbstract
AIMS: This prospective randomized controlled study evaluated the first-line use of a novel remotely monitored implantable loop recorder (ILR) in the initial investigation of unexplained syncope, and compared this to conventional therapy and a dedicated Syncope Clinic (SC). METHODS AND RESULTS: A total of 246 patients (mean age 70.3 years) were randomly allocated to conventional management, SC alone, ILR alone, or SC + ILR. Median follow-up was 20 months (IQR 15-25 months). Time to electrocardiogram (ECG) diagnosis was significantly shorter with ILR alone vs. conventional [hazard ratio (HR) 35.5, P = 0.0004] and with SC vs. conventional (HR 25.6, P = 0.002). Seventy-four per cent of first syncopal events documented in the SC groups occurred during provocative tilt testing. Twenty-two per cent of patients who received an ILR were found to have a bradycardia indication for permanent pacing, compared with 3% of patients who did not. Overall, more investigative tests were undertaken in the conventional group than in any other. Only patients who received an ILR had a significant increase in time to second syncope (P = 0.02), suggesting successful diagnosis and management of treatable causes of syncope. CONCLUSIONS: Implantable loop recorder monitoring achieved a more rapid diagnosis in unexplained syncope than usual care. Conventional management of syncope failed to achieve an ECG diagnosis despite a large number of investigative tests. Syncope Clinic and provocative tilt testing delivered a rapid ECG diagnosis, but did not prevent recurrent syncope. Implantable loop recorders offered rapid diagnosis, increased the likelihood of syncope being reported, demonstrated a high rate of intermittent bradycardia requiring pacing, and reduced recurrent syncope.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
ILR are associated with a shorter time to diagnosis, more frequent treatment initiation, and a positive impact on survival compared to a conventional diagnostic workup.
“with a shorter time to diagnosis, more frequent treatment initiation, and a positive impact on survival compared to a conventional diagnostic workup [13,17,19].”
From Diagnostic Yield and Clinical Implications of Implantable Loop Recorders in Patients with Syncope in Germany: A National Database Analysis (2024) · cites this paper as [17]
The Primary outcome section reports a shorter time to ECG diagnosis with ILR than with conventional management. The Electrocardiogram-directed therapy section reports more pacemaker insertions among ILR recipients (22.4% versus 3.3%), supporting more frequent treatment initiation. The paper reports reduced recurrent syncope, not a positive impact on survival. Page numbers are unavailable in our copy. (LLM, conf=0.90)
Experimental — accuracy not yet measuredThe ILR provided a high diagnostic yield in terms of cardiac arrhythmias in patients with syncope, not restricted to arrhythmias directly related to syncope.
“Hence, the ILR provided a high diagnostic yield in terms of cardiac arrhythmias in patients with syncope, not restricted to arrhythmias directly related to syncope [12,13,14,15,17,19,35,36] but including other diagnoses with therapeutic implications such as atrial fibrillation.”
From Diagnostic Yield and Clinical Implications of Implantable Loop Recorders in Patients with Syncope in Germany: A National Database Analysis (2024) · cites this paper as [17]
The Primary outcome section (page unavailable) reports an ECG diagnosis in 50% of ILR recipients, and the Remotely monitored implantable loop recorder section reports a bradycardia pacing indication in 22%. These findings support substantial diagnostic yield in patients with unexplained syncope, but the paper does not establish that the arrhythmias detected were unrelated to syncopal events. (LLM, conf=0.86)
Experimental — accuracy not yet measuredIn patients with recurrent syncope of uncertain origin, absence of high-risk criteria and structural heart disease, and in suspected reflex syncope, an asystolic pause was present during syncope in about 50% of patients.
“Similar findings were subsequently observed with ILR use expanded in an early phase of evaluation in patients with recurrent syncope of uncertain origin, in the absence of highrisk criteria and structural heart disease, 176,180-183 and in suspected reflex syncope. 184-186 In particular, an asystolic pause was present during syncope in about 50% of these patients.”
From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [176]
The Discussion (page unavailable) identifies the trial as an evaluation of ILRs in recurrent unexplained syncope, supporting that part of the citation. The Primary outcome section reports that 50% of ILR recipients achieved an ECG diagnosis, not that 50% had an asystolic pause during syncope. The paper does not establish the claimed absence of structural heart disease for the study population. (LLM, conf=0.88)
Experimental — accuracy not yet measuredIn a meta-analysis of five randomized controlled trials, initial implantation of an ILR in the workup provided a 3.7 (95% CI 2.7-5.0) increased relative probability of a diagnosis compared with the conventional strategy.
“The results showed that initial implantation of an ILR in the workup provided a 3.7 [95% confidence interval (CI) 2.7-5.0] increased relative probability of a diagnosis compared with the conventional strategy (see Supplementary Data Table 5 ).”
From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [176]
The Primary outcome section reports that ILR patients reached an ECG diagnosis sooner than conventionally managed patients. But this paper reports one randomized trial, not a meta-analysis of five trials, and it does not report the claimed relative probability of 3.7 (95% CI 2.7–5.0). (LLM, conf=0.89)
Experimental — accuracy not yet measuredILR are used to confirm the etiology of syncope.
“Next to noninvasive monitoring strategies, implantable loop recorders (ILR) are used to confirm the etiology of syncope [2,12,13,14,15,16,17,18]”
From Diagnostic Yield and Clinical Implications of Implantable Loop Recorders in Patients with Syncope in Germany: A National Database Analysis (2024) · cites this paper as [17]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Developed in collaboration with, European Heart Rhythm Association (EHRA), Heart Failure Association (HFA), and Heart Rhythm Society (HRS), societies, E. B. T. F., European Society of Emergency Medicine (EuSEM), European Federation of Internal Medicine (EFIM), European Union Geriatric Medicine Society (EUGMS), American Geriatrics Society (AGS), European Neurological Society (ENS), et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp298 · Cited by 2,040 · see citing works
Brignole, M., Menozzi, C., Moya, A., Andresen, D., Blanc, J. J., Krahn, A. D., Wieling, W., Beiras, X., Deharo, J. C., Russo, V., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.082313 · Cited by 437 · see citing works
Brignole, M., Sutton, R., Menozzi, C., Garcia-Civera, R., Moya, A., Wieling, W., Andresen, D., Benditt, D. G., & Vardas, P. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi842 · Cited by 376 · see citing works
Indications for the use of diagnostic implantable and external ECG loop recorders
Task Force members, Brignole, M., Vardas, P., Hoffman, E., Huikuri, H., Moya, A., Ricci, R., Sulke, N., Wieling, W., EHRA Scientific Documents Committee, et al. (2009) · Europace · doi:10.1093/europace/eup097 · Cited by 362 · see citing works
Self-citationUse of an Extended Monitoring Strategy in Patients With Problematic Syncope
Krahn, A. D., Klein, G. J., Yee, R., Takle-Newhouse, T., & Norris, C. (1999) · Circulation · doi:10.1161/01.cir.99.3.406 · Cited by 360 · see citing works
Direct medical costs of syncope-related hospitalizations in the United States
Sun, B. C., Emond, J. A., & Camargo, C. A. (2005) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2004.11.013 · Cited by 305 · see citing works
The clinical impact of implantable loop recorders in patients with syncope
Farwell, D. J., Freemantle, N., & Sulke, N. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi602 · Cited by 219 · see citing works
Self-citationBrignole, M., Ungar, A., Bartoletti, A., Ponassi, I., Lagi, A., Mussi, C., Ribani, M. A., Tava, G., Disertori, M., Quartieri, F., et al. (2006) · EP Europace · doi:10.1093/europace/eul071 · Cited by 193 · see citing works
Use of implantable loop recorders in the diagnosis and management of syncope*1
FARWELL, D. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.03.010 · Cited by 132 · see citing works
Impact of a dedicated syncope and falls facility for older adults on emergency beds
Kenny, R. A. (2002) · Age and Ageing · doi:10.1093/ageing/31.4.272 · Cited by 130 · see citing works
Diagnosis, management, and outcomes of patients with syncope and bundle branch block
Moya, A., Garcia-Civera, R., Croci, F., Menozzi, C., Brugada, J., Ammirati, F., Del Rosso, A., Bellver-Navarro, A., Garcia-Sacristan, J., Bortnik, M., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehr071 · Cited by 124 · see citing works
Paruchuri, V., Adhaduk, M., Garikipati, N. V., Steinberg, J. S., & Mittal, S. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.01.039 · Cited by 28 · see citing works
(2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00369 · Cited by 1 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab364 · Cited by 2,019 · see citing works
2018 ESC Guidelines for the diagnosis and management of syncope
Brignole, M., Moya, A., de Lange, F. J., Deharo, J.-C., Elliott, P. M., Fanciulli, A., Fedorowski, A., Furlan, R., Kenny, R. A., Martín, A., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy037 · Cited by 1,951 · see citing works
2017 ACC/AHA/HRS Guideline for the Evaluation and Management of Patients With Syncope
Shen, W.-K., Sheldon, R. S., Benditt, D. G., Cohen, M. I., Forman, D. E., Goldberger, Z. D., Grubb, B. P., Hamdan, M. H., Krahn, A. D., Link, M. S., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.03.004 · Cited by 484 · see citing works
2017 ACC/AHA/HRS Guideline for the Evaluation and Management of Patients With Syncope
Shen, W.-K., Sheldon, R. S., Benditt, D. G., Cohen, M. I., Forman, D. E., Goldberger, Z. D., Grubb, B. P., Hamdan, M. H., Krahn, A. D., Link, M. S., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.03.003 · Cited by 327 · see citing works
Reed, M. J., Grubb, N. R., Lang, C. C., Gray, A. J., Simpson, K., MacRaild, A., & Weir, C. J. (2018) · Emergency Medicine Journal · doi:10.1136/emermed-2018-207570 · Cited by 28 · see citing works
Diagnostic yield of implantable loop recorders: Results from the Hellenic registry.
Letsas, K. P., Saplaouras, A., Mililis, P., Kariki, O., Bazoukis, G., Archontakis, S., Anagnostopoulos, I., Triantafyllou, S., Palaiodimou, L., Chatziantoniou, A., et al. (2025) · Hellenic Journal of Cardiology · doi:10.1016/j.hjc.2024.05.004 · Cited by 9 · see citing works
Mueller-Leisse, J., Hillmann, H. A. K., Iserloh, L., Fruehauf, B., & Duncker, D. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13061564 · Cited by 5 · see citing works
“Formally, the ICD-10-GM code R55 includes syncope as well as collapse, which may have led to the inclusion of patients without actual syncope.”
BackgroundMethodIndikationen Zur Loop-Rekorder-Implantation Bei Synkope
Schuchert, A. (2018) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-018-0571-1 · Cited by 2 · see citing works
- Authors
- Sulke, N., Sugihara, C., Hong, P., Patel, N., & Freemantle, N.
- Affiliations
- Eastbourne District General Hospital (GB)
- University College London (GB)
- Corresponding author
- Sulke, Neil
- ORCID
- Freemantle, Nick
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2015-10-12
- Volume
- 18
- Issue
- 6
- Pages
- 912-918
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2237521376
- Cited by
- 95
- References
- 14
- Citations by year
- 2026: 13 · 2025: 6 · 2024: 8 · 2023: 10 · 2022: 6 · 2021: 12 · 2020: 4 · 2019: 7 · 2018: 11 · 2017: 12 · 2016: 6
- FWCI
- 9.73
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- EP Europace (publishedVersion)
- PubMed (publishedVersion)
- HighWire Press Open Archive (submittedVersion)
- Funders
- Transoma Medical Inc
- Eastbourne Cardiology Research Charity Fund
- Topics
- Health Sciences › Medicine › Surgery › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- unexplained syncope, implantable loop recorder, remote monitoring, electrocardiographic diagnosis, permanent cardiac pacing, recurrent syncope
- MeSH terms
- Adult, Aged, Aged, 80 and over, Bradycardia, Electrodes, Implanted, Female, United Kingdom, Humans, Male, Middle Aged, Pacemaker, Artificial, Prospective Studies, Recurrence, Syncope, Electrocardiography, Ambulatory, Proportional Hazards Models, Tilt-Table Test
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review