MR-guided focused ultrasound liquid biopsy enriches circulating biomarkers in patients with brain tumors
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Background: Liquid biopsy is promising for early detection, monitoring of response, and recurrence of cancer. The blood-brain barrier (BBB) limits the shedding of biomarker, such as cell-free DNA (cfDNA), into the blood from brain tumors, and their detection by conventional assays. Transcranial MR-guided focused ultrasound (MRgFUS) can safely and transiently open the BBB, providing an opportunity for less-invasive access to brain pathology. We hypothesized that MRgFUS can enrich the signal of circulating brain-derived biomarkers to aid in liquid biopsy. Methods: Nine patients were treated in a prospective single-arm, open-label trial to investigate serial MRgFUS and adjuvant temozolomide combination in patients with glioblastoma (NCT03616860). Blood samples were collected as an exploratory measure within the hours before and after sonication, with control samples from non-brain tumor patients undergoing BBB opening (BBBO) alone (NCT03739905). Results: Brain regions averaging 7.8 ± 6.0 cm3 (range 0.8-23.1 cm3) were successfully treated within 111 ± 39 minutes without any serious adverse events. We found MRgFUS acutely enhanced plasma cfDNA (2.6 ± 1.2-fold, P < .01, Wilcoxon signed-rank test), neuron-derived extracellular vesicles (3.2 ± 1.9-fold, P < .01), and brain-specific protein S100b (1.4 ± 0.2-fold, P < .01). Further comparison of the cfDNA methylation profiles suggests a signature that is disease- and post-BBBO-specific, in keeping with our hypothesis. We also found cfDNA-mutant copies of isocitrate dehydrogenase 1 (IDH1) increased, although this was in only one patient known to harbor the tumor mutation. Conclusions: This first-in-human proof-of-concept study shows MRgFUS enriches the signal of circulating brain-derived biomarkers, demonstrating the potential of the technology to support liquid biopsy for the brain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DNA methylation-based classification of central nervous system tumours
Capper, D., Jones, D. T. W., Sill, M., Hovestadt, V., Schrimpf, D., Sturm, D., Koelsche, C., Sahm, F., Chavez, L., Reuss, D. E., et al. (2018) · Nature · doi:10.1038/nature26000 · Cited by 3,033
Analysis of Circulating Tumor DNA to Monitor Metastatic Breast Cancer
Dawson, S.-J., Tsui, D. W. Y., Murtaza, M., Biggs, H., Rueda, O. M., Chin, S.-F., Dunning, M. J., Gale, D., Forshew, T., Mahler-Araujo, B., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1213261 · Cited by 2,207
The blood–brain barrier and blood–tumour barrier in brain tumours and metastases
Arvanitis, C. D., Ferraro, G. B., & Jain, R. K. (2020) · Nature Reviews Cancer · doi:10.1038/s41568-019-0205-x · Cited by 1,792
Detection of Mutations in EGFR in Circulating Lung-Cancer Cells
Maheswaran, S., Sequist, L. V., Nagrath, S., Ulkus, L., Brannigan, B., Collura, C. V., Inserra, E., Diederichs, S., Iafrate, A. J., Bell, D. W., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0800668 · Cited by 1,617
Sensitive tumour detection and classification using plasma cell-free DNA methylomes
Shen, S. Y., Singhania, R., Fehringer, G., Chakravarthy, A., Roehrl, M. H. A., Chadwick, D., Zuzarte, P. C., Borgida, A., Wang, T. T., Li, T., et al. (2018) · Nature · doi:10.1038/s41586-018-0703-0 · Cited by 983 · cited 1×
“After pre-processing (3) and extraction for specific markers (4), commercially available techniques (5, e.”
MethodBlood-brain barrier opening in Alzheimer’s disease using MR-guided focused ultrasound
Lipsman, N., Meng, Y., Bethune, A. J., Huang, Y., Lam, B., Masellis, M., Herrmann, N., Heyn, C., Aubert, I., Boutet, A., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-04529-6 · Cited by 950
Self-citationClinical trial of blood-brain barrier disruption by pulsed ultrasound
Carpentier, A., Canney, M., Vignot, A., Reina, V., Beccaria, K., Horodyckid, C., Karachi, C., Leclercq, D., Lafon, C., Chapelon, J.-Y., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf6086 · Cited by 757
Hynynen, K., McDannold, N., Sheikov, N. A., Jolesz, F. A., & Vykhodtseva, N. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.06.046 · Cited by 679
Self-citationKinoshita, M., McDannold, N., Jolesz, F. A., & Hynynen, K. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0604318103 · Cited by 645
Self-citationMainprize, T., Lipsman, N., Huang, Y., Meng, Y., Bethune, A., Ironside, S., Heyn, C., Alkins, R., Trudeau, M., Sahgal, A., et al. (2019) · Scientific Reports · doi:10.1038/s41598-018-36340-0 · Cited by 618
Self-citationCirculating tumor DNA and liquid biopsy in oncology
Cescon, D. W., Bratman, S. V., Chan, S. M., & Siu, L. L. (2020) · Nature Cancer · doi:10.1038/s43018-020-0043-5 · Cited by 600
Applications of focused ultrasound in the brain: from thermoablation to drug delivery
Meng, Y., Hynynen, K., & Lipsman, N. (2021) · Nature Reviews Neurology · doi:10.1038/s41582-020-00418-z · Cited by 505
Self-citationAbrahao, A., Meng, Y., Llinas, M., Huang, Y., Hamani, C., Mainprize, T., Aubert, I., Heyn, C., Black, S. E., Hynynen, K., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-12426-9 · Cited by 476
Self-citationMustapic, M., Eitan, E., Werner, J. K., Berkowitz, S. T., Lazaropoulos, M. P., Tran, J., Goetzl, E. J., & Kapogiannis, D. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00278 · Cited by 441
Idbaih, A., Canney, M., Belin, L., Desseaux, C., Vignot, A., Bouchoux, G., Asquier, N., Law-Ye, B., Leclercq, D., Bissery, A., et al. (2019) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-18-3643 · Cited by 362
McDannold, N. J., Vykhodtseva, N. I., & Hynynen, K. (2007) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2006.10.004 · Cited by 155
Self-citationAlkins, R. D., Burgess, A., Kerbel, R. S., Wels, W. S., & Hynynen, K. (2016) · Neuro-Oncology · doi:10.1093/neuonc/nov318 · Cited by 142
Self-citationFocused Ultrasound-enabled Brain Tumor Liquid Biopsy
Zhu, L., Cheng, G., Ye, D., Nazeri, A., Yue, Y., Liu, W., Wang, X., Dunn, G. P., Petti, A. A., Leuthardt, E. C., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-24516-7 · Cited by 118
Sánchez, C., Snyder, M. W., Tanos, R., Shendure, J., & Thierry, A. R. (2018) · npj Genomic Medicine · doi:10.1038/s41525-018-0069-0 · Cited by 108
Feasibility and safety of focused ultrasound-enabled liquid biopsy in the brain of a porcine model
Pacia, C. P., Zhu, L., Yang, Y., Yue, Y., Nazeri, A., Gach, H. M., Talcott, M., Leuthardt, E. C., & Chen, H. (2020) · Scientific Reports · doi:10.1038/s41598-020-64440-3 · Cited by 65
Gutteridge, A., Rathbone, V. M., Gibbons, R., Bi, M., Archard, N., Davies, K. E. J., Brown, J., Plagnol, V., Pillay, N., Amary, F., et al. (2017) · Cancer Medicine · doi:10.1002/cam4.1146 · Cited by 38
Tateishi, K., Wakimoto, H., & Cahill, D. P. (2017) · Neurosurgery · doi:10.1093/neuros/nyx247 · Cited by 34
Cited by
Emerging therapies for glioblastoma: current state and future directions
Rong, L., Li, N., & Zhang, Z. (2022) · Journal of Experimental & Clinical Cancer Research · doi:10.1186/s13046-022-02349-7 · Cited by 510
Applications of focused ultrasound-mediated blood-brain barrier opening
Gorick, C. M., Breza, V. R., Nowak, K. M., Cheng, V. W. T., Fisher, D. G., Debski, A. C., Hoch, M. R., Demir, Z. E. F., Tran, N. M., Schwartz, M. R., et al. (2022) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2022.114583 · Cited by 144
Meng, Y., Goubran, M., Rabin, J. S., McSweeney, M., Ottoy, J., Pople, C. B., Huang, Y., Storace, A., Ozzoude, M., Bethune, A., et al. (2023) · Brain · doi:10.1093/brain/awac459 · Cited by 83
Self-citationBae, S., Liu, K., Pouliopoulos, A. N., Ji, R., Jiménez-Gambín, S., Yousefian, O., Kline-Schoder, A. R., Batts, A. J., Tsitsos, F. N., Kokossis, D., et al. (2024) · Theranostics · doi:10.7150/thno.94206 · Cited by 70
“The elevated levels of EV biomarkers indicate the release of proteins to the bloodstream by FUS, consistent with sonobiopsy behavior noted in prior studies [59,60].”
Liquid biopsy: creating opportunities in brain space
Trivedi, R., & Bhat, K. P. (2023) · British Journal of Cancer · doi:10.1038/s41416-023-02446-0 · Cited by 27
“In another advanced study, spatial precision to create temporary brain openings was achieved using low-intensity MR in conjunction with FUS [280].”
Metadata
- Authors
- Meng, Y., Pople, C. B., Suppiah, S., Llinas, M., Huang, Y., Sahgal, A., Perry, J., Keith, J., Davidson, B., Hamani, C., Amemiya, Y., Seth, A., Leong, H., Heyn, C. C., Aubert, I., Hynynen, K., & Lipsman, N.
- Venue
- Neuro-Oncology
- Publisher
- Oxford University Press (OUP)
- Published
- 2021-03-10
- Volume
- 23
- Issue
- 10
- Pages
- 1789-1797
- ISSN
- 1522-8517 (ISSN-L)
- 1523-5866
- OpenAlex
- W3134763185
- Cited by
- 166
- References
- 22
- FWCI
- 6.37
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.