The DOI matches its Crossref record.
How Accurately Does Wrist Actigraphy Identify the States of Sleep and Wakefulness?
Open accessAbstract
STUDY OBJECTIVES: Because sleep and wakefulness differ from each other by the amount of body movement, it has been claimed that the two states can be accurately distinguished by wrist actigraphy. Our objective was to test this claim in lengthy polysomnographic (psg) and actigraphic (acf) samples that included night and day components. DESIGN: Fourteen healthy young (21-35 years) and old (70-72 years) men and women lived in a laboratory without temporal cues for 7 days. Each subject continuously wore sleep-recording electrodes as well as 2 wrist-movement recorders. Act measurements were converted to predictions of sleep and wakefulness by simple-threshold and multiple-regression methods. Psg served as the gold standard for calculation of predictive values (PV, the probability that an act prediction is correct by psg criteria). SETTING: N/A. PARTICIPANTS: N/A. INTERVENTIONS: N/A. MEASUREMENTS AND RESULTS: The 7-day act recordings showed clear circadian cycles of high and low activity that respectively corresponded to subjective days, when subjects were wakeful, and subjective nights when they slept. Lower act levels corresponded to deeper states of psg sleep. Logistic regression on a 20-minute moving average of act gave the highest overall PV's. Nevertheless, the mean PV for sleep (PVS) was only 62.2% in complete, day + night samples. PVS was 86.6% in night samples. Act successfully predicted wakefulness during subjective nights (PVW = 89.6) and accurately measured circadian period length and the extent of sleep-wake consolidation, but it overestimated sleep rate and sleep efficiency. Act systematically decreased before sleep onset and increased before awakening, but reliable transitions among joint psg/act states (the Markov-1 property) were not demonstrated. CONCLUSIONS: Low PV's and overestimation of sleep currently disqualify actigraphy as an accurate sleep-wake indicator. Actigraphy may, however, by useful for measuring circadian period and sleep-wake consolidation and has face validity as a measure of rest/activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Role of Actigraphy in the Study of Sleep and Circadian Rhythms
Ancoli-Israel, S., Cole, R., Alessi, C., Chambers, M., Moorcroft, W., & Pollak, C. P. (2003) · Sleep · doi:10.1093/sleep/26.3.342 · Cited by 2,751
Self-citationStunkard, A. J., Faith, M. S., & Allison, K. C. (2003) · Biological Psychiatry · doi:10.1016/s0006-3223(03)00608-5 · Cited by 821
Use of actigraphy for assessment in pediatric sleep research
Meltzer, L. J., Montgomery-Downs, H. E., Insana, S. P., & Walsh, C. M. (2012) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2011.10.002 · Cited by 628
Wearable Sleep Technology in Clinical and Research Settings
DE ZAMBOTTI, M., CELLINI, N., GOLDSTONE, A., COLRAIN, I. M., & BAKER, F. C. (2019) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001947 · Cited by 564
The SBSM Guide to Actigraphy Monitoring: Clinical and Research Applications
Ancoli-Israel, S., Martin, J. L., Blackwell, T., Buenaver, L., Liu, L., Meltzer, L. J., Sadeh, A., Spira, A. P., & Taylor, D. J. (2015) · Behavioral Sleep Medicine · doi:10.1080/15402002.2015.1046356 · Cited by 559
Tranah, G. J., Blackwell, T., Stone, K. L., Ancoli‐Israel, S., Paudel, M. L., Ensrud, K. E., Cauley, J. A., Redline, S., Hillier, T. A., Cummings, S. R., et al. (2011) · Annals of Neurology · doi:10.1002/ana.22468 · Cited by 525
VAN DE WATER, A. T. M., HOLMES, A., & HURLEY, D. A. (2011) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2009.00814.x · Cited by 447
Miller, D. J., Sargent, C., & Roach, G. D. (2022) · Sensors · doi:10.3390/s22166317 · Cited by 328
Nighttime Insomnia Treatment and Education for Alzheimer's Disease: A Randomized, Controlled Trial
McCurry, S. M., Gibbons, L. E., Logsdon, R. G., Vitiello, M. V., & Teri, L. (2005) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2005.53252.x · Cited by 315
Comparison of Sleep Parameters from Actigraphy and Polysomnography in Older Women: The SOF Study
Blackwell, T., Redline, S., Ancoli-Israel, S., Schneider, J. L., Surovec, S., Johnson, N. L., Cauley, J. A., & Stone, K. L. (2008) · Sleep · doi:10.1093/sleep/31.2.283 · Cited by 292
Zinkhan, M., Berger, K., Hense, S., Nagel, M., Obst, A., Koch, B., Penzel, T., Fietze, I., Ahrens, W., Young, P., et al. (2014) · Sleep Medicine · doi:10.1016/j.sleep.2014.04.015 · Cited by 232
Circadian eating and sleeping patterns in the night eating syndrome
O'Reardon, J. P., Ringel, B. L., Dinges, D. F., Allison, K. C., Rogers, N. L., Martino, N. S., & Stunkard, A. J. (2004) · Obesity Research · doi:10.1038/oby.2004.222 · Cited by 223
Validation of an automated wireless system to monitor sleep in healthy adults
SHAMBROOM, J. R., FÁBREGAS, S. E., & JOHNSTONE, J. (2012) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2011.00944.x · Cited by 216
Sleep and wake classification with ECG and respiratory effort signals
Karlen, W., Mattiussi, C., & Floreano, D. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.2008817 · Cited by 134
(2005) · PubMed · Cited by 123
Poor sleep in PCOS; is melatonin the culprit?
Shreeve, N., Cagampang, F., Sadek, K., Tolhurst, M., Houldey, A., Hill, C. M., Brook, N., Macklon, N., & Cheong, Y. (2013) · Human Reproduction · doi:10.1093/humrep/det013 · Cited by 73
Agreement between sleep diary and actigraphy in a highly educated Brazilian population
Campanini, M. Z., Lopez-Garcia, E., Rodríguez-Artalejo, F., González, A. D., Andrade, S. M., & Mesas, A. E. (2017) · Sleep Medicine · doi:10.1016/j.sleep.2017.04.004 · Cited by 67
Smagula, S. F., Ancoli-Israel, S., Blackwell, T., Boudreau, R., Stefanick, M. L., Paudel, M. L., Stone, K. L., & Cauley, J. A. (2015) · The American Journal of Geriatric Psychiatry · doi:10.1016/j.jagp.2014.06.007 · Cited by 63
Smagula, S. F., Boudreau, R. M., Stone, K., Reynolds, C. F., Bromberger, J. T., Ancoli-Israel, S., Dam, T.-T., Barrett-Connor, E., & Cauley, J. A. (2015) · Chronobiology International · doi:10.3109/07420528.2015.1102925 · Cited by 46
“The Epworth Sleepiness Scale (ESS) was also expressed as a continuous measure of excessive daytime sleepiness ranging from 0 to 24 (Johns, 1991).”
MethodSano, A., & Picard, R. W. (2014) · 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2014.6943744 · Cited by 25
Metadata
- Authors
- Pollak, C. P., Tryon, W. W., Nagaraja, H., & Dzwonczyk, R.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-12
- Volume
- 24
- Issue
- 8
- Pages
- 957-965
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W119672040
- Cited by
- 223
- References
- 0
- FWCI
- 5.87
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.