Predicting circadian misalignment with wearable technology: validation of wrist-worn actigraphy and photometry in night shift workers
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Study Objectives: A critical barrier to successful treatment of circadian misalignment in shift workers is determining circadian phase in a clinical or field setting. Light and movement data collected passively from wrist actigraphy can generate predictions of circadian phase via mathematical models; however, these models have largely been tested in non-shift working adults. This study tested the feasibility and accuracy of actigraphy in predicting dim light melatonin onset (DLMO) in fixed night shift workers. Methods: A sample of 45 night shift workers wore wrist actigraphs before completing DLMO in the laboratory (17.0 days ± 10.3 SD). DLMO was assessed via 24 hourly saliva samples in dim light (<10 lux). Data from actigraphy were provided as input to a mathematical model to generate predictions of circadian phase. Agreement was assessed and compared to average sleep timing on non-workdays as a proxy of DLMO. Model code and an open-source prototype assessment tool are available (www.predictDLMO.com). Results: Model predictions of DLMO showed good concordance with in-lab DLMO, with Lin’s concordance coefficient of 0.70, which was twice as high as agreement using average sleep timing as a proxy of DLMO. The absolute mean error of the predictions was 2.88 h, with 76% and 91% of the predictions falling with 2 and 4 h, respectively. Conclusion: This study is the first to demonstrate the use of wrist actigraphy-based estimates of circadian phase as a clinically useful and valid alternative to in-lab measurement of DLMO in fixed night shift workers. Future research should explore how additional predictors may impact accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adverse metabolic and cardiovascular consequences of circadian misalignment
Scheer, F. A. J. L., Hilton, M. F., Mantzoros, C. S., & Shea, S. A. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0808180106 · Cited by 2,351
Health consequences of shift work and insufficient sleep
Kecklund, G., & Axelsson, J. (2016) · BMJ · doi:10.1136/bmj.i5210 · Cited by 1,195 · cited 1×
“However, night shift work exposes employees to circadian misalignment, which significantly increases risk for adverse health and safety outcomes including shift work disorder [1, 2], vehicular accidents [3], cancer [4], obesity [5], and cardiovascular morbidity and mortality [6, 7] ((for reviews, see [8, 9]).”
Shift Work Sleep Disorder: Prevalence and Consequences Beyond that of Symptomatic Day Workers
Drake, C. L., Roehrs, T., Richardson, G., Walsh, J. K., & Roth, T. (2004) · Sleep · doi:10.1093/sleep/27.8.1453 · Cited by 860
Self-citationPhillips, A. J. K., Clerx, W. M., O’Brien, C. S., Sano, A., Barger, L. K., Picard, R. W., Lockley, S. W., Klerman, E. B., & Czeisler, C. A. (2017) · Scientific Reports · doi:10.1038/s41598-017-03171-4 · Cited by 647 · cited 2×
“[19] (DLMO ranged approximately from 6:00 pm to 3:00 am), even the most irregular sleeper in that sample—albeit likely a late chronotype—slept predominantly at night (i.”
Phillips, A. J. K., Vidafar, P., Burns, A. C., McGlashan, E. M., Anderson, C., Rajaratnam, S. M. W., Lockley, S. W., & Cain, S. W. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1901824116 · Cited by 430 · cited 1×
“For example, a recent article found remarkable individual variation in sensitivity to evening light as indexed by melatonin suppression [42].”
The Dim Light Melatonin Onset as a Marker for Orcadian Phase Position
Lewy, A. J., & Sack, R. L. (1989) · Chronobiology International · doi:10.3109/07420528909059144 · Cited by 418
Meta-analysis on shift work and risks of specific obesity types
Sun, M., Feng, W., Wang, F., Li, P., Li, Z., Li, M., Tse, G., Vlaanderen, J., Vermeulen, R., & Tse, L. A. (2018) · Obesity Reviews · doi:10.1111/obr.12621 · Cited by 391 · cited 1×
“…shift work exposes employees to circadian misalignment, which significantly increases risk for adverse health and safety outcomes including shift work disorder [1, 2], vehicular accidents [3], cancer [4], obesity [5], and cardiovascular morbidity and mortality [6, 7] ((for reviews, see [8, 9]).”
Kantermann, T., Sung, H., & Burgess, H. J. (2015) · Journal of Biological Rhythms · doi:10.1177/0748730415597520 · Cited by 323
Self-citationRuben, M. D., Wu, G., Smith, D. F., Schmidt, R. E., Francey, L. J., Lee, Y. Y., Anafi, R. C., & Hogenesch, J. B. (2018) · Science Translational Medicine · doi:10.1126/scitranslmed.aat8806 · Cited by 314 · cited 1×
“As such, there has been significant interest in the development of alternatives to DLMO [13–16].”
The impact of the circadian timing system on cardiovascular and metabolic function
Morris, C. J., Yang, J. N., & Scheer, F. A. J. L. (2012) · Progress in Brain Research · doi:10.1016/b978-0-444-59427-3.00019-8 · Cited by 215
MORENO, C. R. C., MARQUEZE, E. C., SARGENT, C., WRIGHT Jr, K. P., FERGUSON, S. A., & TUCKER, P. (2019) · Industrial Health · doi:10.2486/indhealth.sw-1 · Cited by 212
Burgess, H. J., Savic, N., Sletten, T., Roach, G., Gilbert, S. S., & Dawson, D. (2003) · Behavioral Sleep Medicine · doi:10.1207/s15402010bsm0102_3 · Cited by 125 · cited 1×
“Operationally, a circular average of the timing of sleep derived via actigraphy was conducted by workdays and non-workdays for each participant, and DLMO was estimated at 2 h prior to average sleep time based on typical phase angle between DLMO and sleep time(1) [32, 35, 36].”
Self-citationSt. Hilaire, M. A., Klerman, E. B., Khalsa, S. B. S., Wright, K. P., Czeisler, C. A., & Kronauer, R. E. (2007) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2007.04.001 · Cited by 109
Cited by
Circadian rhythms and disorders of the timing of sleep
Meyer, N., Harvey, A. G., Lockley, S. W., & Dijk, D.-J. (2022) · The Lancet · doi:10.1016/s0140-6736(22)00877-7 · Cited by 346
Circadian depression: A mood disorder phenotype
Carpenter, J. S., Crouse, J. J., Scott, E. M., Naismith, S. L., Wilson, C., Scott, J., Merikangas, K. R., & Hickie, I. B. (2021) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2021.02.045 · Cited by 114
The real-world association between digital markers of circadian disruption and mental health risks
Lee, M. P., Kim, D. W., Fang, Y., Kim, R., Bohnert, A. S. B., Sen, S., & Forger, D. B. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01348-6 · Cited by 29
“…fi cant positive correlation is not evident if CRCO is estimated using conventional approaches that solely rely on mathematical model simulation 18,43 (see Methods for details) but do not incorporate indirect information about the CRCO from other circadian biomarkers in predicting CRCO phase…”
Self-citationFrom Microbial Switches to Metabolic Sensors: Rewiring the Gut–Brain Kynurenine Circuit
Tanaka, M., & Vécsei, L. (2025) · doi:10.20944/preprints202506.0880.v1 · Cited by 24
Metadata
- Authors
- Cheng, P., Walch, O., Huang, Y., Mayer, C., Sagong, C., Cuamatzi Castelan, A., Burgess, H. J., Roth, T., Forger, D. B., & Drake, C. L.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 2020-09-11
- Volume
- 44
- Issue
- 2
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W3085362956
- Cited by
- 88
- References
- 13
- FWCI
- 3.98
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.