The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Transport‐mediated angiogenesis in 3D epithelial coculture
Open accessAbstract
Increasing interest has focused on capturing the complexity of tissues and organs in vitro as models of human pathophysiological processes. In particular, a need exists for a model that can investigate the interactions in three dimensions (3D) between epithelial tissues and a microvascular network since vascularization is vital for reconstructing functional tissues in vitro . Here, we implement a microfluidic platform to analyze angiogenesis in 3D cultures of rat primary hepatocytes and rat/human microvascular endothelial cells (rMVECs/hMVECs). Liver and vascular cells were cultured on each sidewall of a collagen gel scaffold between two microfluidic channels under static or flow conditions. Morphogenesis of 3D hepatocyte cultures was found to depend on diffusion and convection across the nascent tissue. Furthermore, rMVECs formed 3D capillary‐like structures that extended across an intervening gel to the hepatocyte tissues in hepatocyterMVEC coculture while they formed 2D sheet‐like structures in rMVEC monoculture. In addition, diffusion of fluorescent dextran across the gel scaffold was analyzed, demonstrating that secreted proteins from the hepatocytes and MVECs can be exchanged across the gel scaffold by diffusional transport. The experimental approach described here is useful more generally for investigating microvascular networks within 3D engineered tissues with multiple cell types in vitro . —Sudo, R.,Chung, S., Zervantonakis, I. K., Vickerman, V., Toshimitsu, Y., Griffith, L. G., Kamm, R. D. Transportmediated angiogenesis in 3D epithelial coculture. FASEBJ. 23, 2155–2164 (2009)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modeling Tissue Morphogenesis and Cancer in 3D
Yamada, K. M., & Cukierman, E. (2007) · Cell · doi:10.1016/j.cell.2007.08.006 · Cited by 1,751
Bhatia, S. N., Balis, U. J., Yarmush, M. L., & Toner, M. (1999) · The FASEB Journal · doi:10.1096/fasebj.13.14.1883 · Cited by 890 · cited 1×
“By controlling temporal cell–cell interactions in a 2D microdevice, it was found that the interaction was essential for maintaining hepatocyte differentiation (23, 24).”
BackgroundA novel 3D mammalian cell perfusion-culture system in microfluidic channels
Toh, Y.-C., Zhang, C., Zhang, J., Khong, Y. M., Chang, S., Samper, V. D., van Noort, D., Hutmacher, D. W., & Yu, H. (2007) · Lab on a Chip · doi:10.1039/b614872g · Cited by 414
Cited by
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
Designing materials to direct stem-cell fate
Lutolf, M. P., Gilbert, P. M., & Blau, H. M. (2009) · Nature · doi:10.1038/nature08602 · Cited by 1,393
Three-dimensional microfluidic model for tumor cell intravasation and endothelial barrier function
Zervantonakis, I. K., Hughes-Alford, S. K., Charest, J. L., Condeelis, J. S., Gertler, F. B., & Kamm, R. D. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1210182109 · Cited by 872
“Themicrofluidic device design is based on previous work from our lab on forming endothelial sprouts under growth-factor gradients and the fabrication protocols are described in detail elsewhere (46).”
MethodSelf-citationEngineers are from PDMS-land, Biologists are from Polystyrenia
Berthier, E., Young, E. W. K., & Beebe, D. (2012) · Lab on a Chip · doi:10.1039/c2lc20982a · Cited by 799
Microfluidic assay for simultaneous culture of multiple cell types on surfaces or within hydrogels
Shin, Y., Han, S., Jeon, J. S., Yamamoto, K., Zervantonakis, I. K., Sudo, R., Kamm, R. D., & Chung, S. (2012) · Nature Protocols · doi:10.1038/nprot.2012.051 · Cited by 617
Self-citationA microfluidic platform integrating functional vascularized organoids-on-chip
Quintard, C., Tubbs, E., Jonsson, G., Jiao, J., Wang, J., Werschler, N., Laporte, C., Pitaval, A., Bah, T.-S., Pomeranz, G., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-45710-4 · Cited by 387
Biological applications of microfluidic gradient devices
Kim, S., Kim, H. J., & Jeon, N. L. (2010) · Integrative Biology · doi:10.1039/c0ib00055h · Cited by 366
Organ-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
Microfluidic techniques for development of 3D vascularized tissue
Hasan, A., Paul, A., Vrana, N. E., Zhao, X., Memic, A., Hwang, Y.-S., Dokmeci, M. R., & Khademhosseini, A. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.04.091 · Cited by 282
“[148] who implemented a microfluidic platform made of a micropatterned PDMS with two parallel microfluidic channels connected using an intervening 3D collagen gel to analyze the angiogenesis using primary rat hepatocytes and microvascular ECs (rMVECs).”
In vitro model of tumor cell extravasation
Jeon, J. S., Zervantonakis, I. K., Chung, S., Kamm, R. D., & Charest, J. L. (2013) · PLoS ONE · doi:10.1371/journal.pone.0056910 · Cited by 233
“situation in a controlled environment while simultaneously providing in situ imaging capabilities for visualization, thereby enabling quantification of cell-cell and cell-matrix interactions [25,26,27,28].”
BackgroundSelf-citationYoon No, D., Lee, K.-H., Lee, J., & Lee, S.-H. (2015) · Lab on a Chip · doi:10.1039/c5lc00611b · Cited by 205
Migration dynamics of breast cancer cells in a tunable 3D interstitial flow chamber
Haessler, U., Teo, J. C. M., Foretay, D., Renaud, P., & Swartz, M. A. (2012) · Integrative Biology · doi:10.1039/c1ib00128k · Cited by 176
A quantitative microfluidic angiogenesis screen for studying anti-angiogenic therapeutic drugs
Kim, C., Kasuya, J., Jeon, J., Chung, S., & Kamm, R. D. (2015) · Lab on a Chip · doi:10.1039/c4lc00866a · Cited by 143
Self-citationA multilayered microfluidic blood vessel-like structure
Hasan, A., Paul, A., Memic, A., & Khademhosseini, A. (2015) · Biomedical Microdevices · doi:10.1007/s10544-015-9993-2 · Cited by 139
“…of specific cell types under controlled microenvironments are used for promoting the formation of microvascular-like structures (Chung et al. 2009; Sudo et al. 2009; Saik et al. 2012; Leslie-Barbick et al. 2009, 2011a, b; Chen et al. 2007; Cao et al. 2009; Yuen et al. 2010; Yeon et al. 2012;…”
InfluentialIn Vitro Strategies to Vascularize 3D Physiologically Relevant Models
Dellaquila, A., Le Bao, C., Letourneur, D., & Simon‐Yarza, T. (2021) · Advanced Science · doi:10.1002/advs.202100798 · Cited by 115
Lee, S. W. L., Seager, R. J., Litvak, F., Spill, F., Sieow, J. L., Leong, P. H., Kumar, D., Tan, A. S. M., Wong, S. C., Adriani, G., et al. (2020) · Integrative Biology · doi:10.1093/intbio/zyaa007 · Cited by 60
Huang, Y.-H., Watanabe, M., Yamashita, T., & Sudo, R. (2025) · Biofabrication · doi:10.1088/1758-5090/adc8d4 · Cited by 3
Self-citation
Metadata
- Authors
- Sudo, R., Chung, S., Zervantonakis, I. K., Vickerman, V., Toshimitsu, Y., Griffith, L. G., & Kamm, R. D.
- Venue
- The FASEB Journal
- Publisher
- Wiley
- Published
- 2009-02-26
- Volume
- 23
- Issue
- 7
- Pages
- 2155-2164
- ISSN
- 0892-6638 (ISSN-L)
- 1530-6860
- OpenAlex
- W2045911112
- Cited by
- 201
- References
- 3
- FWCI
- 12.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.