Propofol Blood Concentration and the Bispectral Index Predict Suppression of Learning During Propofol/Epidural Anesthesia in Volunteers
The DOI matches its Crossref record.
Abstract
Propofol is often used for sedation during regional anesthesia. We tested the hypothesis that propofol blood concentration, the Bispectral Index and the 95% spectral edge frequency predict suppression of learning during propofol/epidural anesthesia in volunteers. In addition, we tested the hypothesis that the Bispectral Index is linearly related to propofol blood concentration. Fourteen healthy, male volunteers were studied on three randomly ordered days: no propofol, target propofol blood concentration 1 microgram/mL, and target propofol blood concentration 2 micrograms/mL. Each day, epidural anesthesia (approximately T11 level) was induced using 2% 2-chloroprocaine. Propofol was infused by a computer-controlled pump, and propofol concentration measured in central venous blood. We administered a Trivial Pursuit-type question task on all 3 days. The electroencephalogram was monitored continuously (Fp1, Fp2; reference, Cz; ground, mastoid). Propofol caused concentration-related impairment of learning. The propofol blood concentration suppressing learning by 50% was 0.66 +/- 0.1 microgram/mL. The Bispectral Index value when learning was suppressed by 50% was 91 +/- 1. In contrast, the 95% spectral edge frequency did not correlate well with learning. The Bispectral Index decreased linearly as propofol blood concentration increased (Bispectral Index = -7.4.[propofol] + 90; r2 = 0.47, n = 278). There was no significant correlation between the 95% spectral edge frequency and propofol concentration. In order to suppress learning, propofol blood concentrations reported to produce amnesia may be targeted. Alternatively, the Bispectral Index may be used to predict anesthetic effect during propofol sedation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Primer for EEG Signal Processing in Anesthesia
Rampil, I. J. (1998) · Anesthesiology · doi:10.1097/00000542-199810000-00023 · Cited by 1,503
Myles, P., Leslie, K., McNeil, J., Forbes, A., & Chan, M. (2004) · The Lancet · doi:10.1016/s0140-6736(04)16300-9 · Cited by 1,301
Self-citationGlass, P. S., Bloom, M., Kearse, L., Rosow, C., Sebel, P., & Manberg, P. (1997) · Anesthesiology · doi:10.1097/00000542-199704000-00014 · Cited by 1,274
Development and Clinical Application of Electroencephalographic Bispectrum Monitoring
Johansen, J. W., Sebel, P. S., & Fisher, D. M. (2000) · Anesthesiology · doi:10.1097/00000542-200011000-00029 · Cited by 599
Liu, J., Singh, H., & White, P. F. (1997) · Anesthesia & Analgesia · doi:10.1097/00000539-199701000-00033 · Cited by 432
Guignard, B., Menigaux, C., Dupont, X., Fletcher, D., & Chauvin, M. (2000) · Anesthesia & Analgesia · doi:10.1097/00000539-200001000-00034 · Cited by 360
Depth of anaesthesia monitoring: what’s available, what’s validated and what’s next?
Bruhn, J., Myles, P. S., Sneyd, R., & Struys, M. M. R. F. (2006) · British Journal of Anaesthesia · doi:10.1093/bja/ael120 · Cited by 341
Kearse, L. A., Rosow, C., Zaslavsky, A., Connors, P., Dershwitz, M., & Denman, W. (1998) · Anesthesiology · doi:10.1097/00000542-199801000-00007 · Cited by 309
A Multicenter Study of Bispectral Electroencephalogram Analysis for Monitoring Anesthetic Effect
Sebel, P. S., Lang, E., Rampil, I. J., White, P. F., Cork, R., Jopling, M., Smith, N. T., Glass, P. S. A., & Manberg, P. (1997) · Anesthesia & Analgesia · doi:10.1213/00000539-199704000-00035 · Cited by 302
Sun, L., Ma, W., Gao, W., Xing, Y., Chen, L., Xia, Z., Zhang, Z., & Dai, Z. (2019) · Cell Death & Disease · doi:10.1038/s41419-019-1761-4 · Cited by 296
Billard, V., Gambus, P. L., Chamoun, N., Stanski, D. R., & Shafer, S. L. (1997) · Clinical Pharmacology & Therapeutics · doi:10.1016/s0009-9236(97)90181-8 · Cited by 270
Iselin-Chaves, I. A., Flaishon, R., Sebel, P. S., Howell, S., Gan, T. J., Sigl, J., Ginsberg, B., & Glass, P. S. A. (1998) · Anesthesia & Analgesia · doi:10.1097/00000539-199810000-00038 · Cited by 267
Bispectral Index Monitoring during Sedation with Sevoflurane, Midazolam, and Propofol
Ibrahim, A. E., Taraday, J. K., & Kharasch, E. D. (2001) · Anesthesiology · doi:10.1097/00000542-200111000-00019 · Cited by 259
Doi, M., Gajraj, R. J., Mantzaridis, H., & Kenny, G. N. (1997) · British Journal of Anaesthesia · doi:10.1093/bja/78.2.180 · Cited by 238
Veselis, R. A., Reinsel, R. A., Feshchenko, V. A., & Wronski, M. (1997) · Anesthesiology · doi:10.1097/00000542-199710000-00007 · Cited by 226
Bispectral EEG Index during Nitrous Oxide Administration
Rampil, I. J., Kim, J.-S., Lenhardt, R., Negishi, C., & Sessler, D. I. (1998) · Anesthesiology · doi:10.1097/00000542-199809000-00017 · Cited by 221
Self-citationClinical Practice Advisory: Emergency Department Procedural Sedation With Propofol
Miner, J. R., & Burton, J. H. (2007) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2006.12.017 · Cited by 221
“Propofol Administration: Pharmacology Although individual patient response will vary, the sedative effects of propofol are typically dose dependent.(50,51) The onset of clinical sedation is usually within 30 seconds from injection.”
BackgroundKazama, T., Ikeda, K., Morita, K., Kikura, M., Doi, M., Ikeda, T., Kurita, T., & Nakajima, Y. (1999) · Anesthesiology · doi:10.1097/00000542-199906000-00004 · Cited by 197
Depth of Anesthesia and Bispectral Index Monitoring
Kissin, I. (2000) · Anesthesia & Analgesia · doi:10.1097/00000539-200005000-00021 · Cited by 197
“(46) reported that the BIS predicted propofol-induced suppression of learning during regional anesthesia.”
BackgroundSchneider, G., Gelb, A. W., Schmeller, B., Tschakert, R., & Kochs, E. (2003) · British Journal of Anaesthesia · doi:10.1093/bja/aeg188 · Cited by 158
“Results. At non-responsiveness, BIS (66 (17)) and PSI (55 (23)) were significantly less than at responsiveness (BIS, 79 (14); PSI, 77 ( 18 ); P 18 ).”
Background
Metadata
- Authors
- Leslie, K., Sessler, D. I., Schroeder, M., & Walters, K.
- Venue
- Anesthesia & Analgesia
- Published
- 1995-12
- Volume
- 81
- Issue
- 6
- Pages
- 1269-1274
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2029696555
- Cited by
- 174
- References
- 0
- FWCI
- 11.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.