Acute Left Ventricular Dysfunction during Unsuccessful Weaning from Mechanical Ventilation
Open accessThe DOI matches its Crossref record.
Abstract
The authors studied the hemodynamic effects of rapidly weaning from mechanical ventilation (MV) 15 patients with severe chronic obstructive pulmonary disease (COPD) and cardiovascular disease who were recovering from acute cardiopulmonary decompensation. In each patient, 10 min of spontaneous ventilation (SV) with supplemental oxygen resulted in reducing the mean esophageal pressure (X +/- SD, + 5 +/- 3 to -2 +/- 2.5 mmHg, P less than .01) and increasing cardiac index (CI) 3.2 +/- 0.9 to 4.3 +/- 1.3 1/min/M2, P less than .001), systemic blood pressure (BP 77 +/- 12 to 90 +/- 11 mmHg, P less than .001), heart rate (HR 97 +/- 12 to 112 +/- 16 beats/min, P less than .001), and, most importantly, transmural pulmonary artery occlusion pressure markedly increased (PAOPtm 8 +/- 5 to 25 +/- 13 mmHg, P less than .001), mandating a reinstitution of MV. In four patients with left ventricular (LV) catheters, the PAOP correlated with the LV end-diastolic pressure during both MV and SV. Gated blood pool imaging showed SV increased the LV end-diastolic volume index (65 +/- 24 to 83 +/- 32/M2, P less than .002) with LV ejection fraction unchanged. Patients were treated for a mean of 10 days with diuretics, resulting in a reduction of blood volume (4.55 +/- 0.9 1 to 3.56 +/- 0.55 1) and body weight (-5 kg, P less than .001). Subsequently, nine of the 15 patients were weaned successfully from mechanical ventilation with unchanged PAOP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Weaning from mechanical ventilation
Boles, J.-M., Bion, J., Connors, A., Herridge, M., Marsh, B., Melot, C., Pearl, R., Silverman, H., Stanchina, M., Vieillard-Baron, A., et al. (2007) · European Respiratory Journal · doi:10.1183/09031936.00010206 · Cited by 2,064
Evidence-Based Guidelines for Weaning and Discontinuing Ventilatory Support
MacIntyre, N. R. (2001) · Chest · doi:10.1378/chest.120.6_suppl.375s · Cited by 1,240
Extubation Outcome after Spontaneous Breathing Trials with T-Tube or Pressure Support Ventilation
ESTEBAN, A., ALÍA, I., GORDO, F., FERNÁNDEZ, R., SOLSONA, J. F., VALLVERDÚ, I., MACÍAS, S., ALLEGUE, J. M., BLANCO, J., CARRIEDO, D., et al. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.156.2.9610109 · Cited by 795
The Application of Esophageal Pressure Measurement in Patients with Respiratory Failure
Akoumianaki, E., Maggiore, S. M., Valenza, F., Bellani, G., Jubran, A., Loring, S. H., Pelosi, P., Talmor, D., Grasso, S., Chiumello, D., et al. (2014) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201312-2193ci · Cited by 635
The Decision to Extubate in the Intensive Care Unit
Thille, A. W., Richard, J.-C. M., & Brochard, L. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201208-1523ci · Cited by 576
Slutsky, A. S. (1993) · Chest · doi:10.1378/chest.104.6.1833 · Cited by 563
Esophageal and transpulmonary pressure in the clinical setting: meaning, usefulness and perspectives
Mauri, T., Yoshida, T., Bellani, G., Goligher, E. C., Carteaux, G., Rittayamai, N., Mojoli, F., Chiumello, D., Piquilloud, L., Grasso, S., et al. (2016) · Intensive Care Medicine · doi:10.1007/s00134-016-4400-x · Cited by 554
Management of Patients Requiring Prolonged Mechanical Ventilation
MacIntyre, N. R., Epstein, S. K., Carson, S., Scheinhorn, D., Christopher, K., & Muldoon, S. (2005) · Chest · doi:10.1378/chest.128.6.3937 · Cited by 533
Soummer, A., Perbet, S., Brisson, H., Arbelot, C., Constantin, J.-M., Lu, Q., & Rouby, J.-J. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e31824e68ae · Cited by 519
Advances in Mechanical Ventilation
Tobin, M. J. (2001) · New England Journal of Medicine · doi:10.1056/nejm200106283442606 · Cited by 475
Risk Factors for Extubation Failure in Patients Following a Successful Spontaneous Breathing Trial
Frutos-Vivar, F., Ferguson, N. D., Esteban, A., Epstein, S. K., Arabi, Y., Apezteguía, C., González, M., Hill, N. S., Nava, S., D’Empaire, G., et al. (2006) · Chest · doi:10.1378/chest.130.6.1664 · Cited by 406
Fluid responsiveness in mechanically ventilated patients: a review of indices used in intensive care
Bendjelid, K., & Romand, J.-A. (2003) · Intensive Care Medicine · doi:10.1007/s00134-002-1615-9 · Cited by 366
GIRAULT, C., DAUDENTHUN, I., CHEVRON, V., TAMION, F., LEROY, J., & BONMARCHAND, G. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.160.1.9802120 · Cited by 365
Cardiovascular Issues in Respiratory Care
Pinsky, M. R. (2005) · Chest · doi:10.1378/chest.128.5_suppl_2.592s · Cited by 322
Epstein, S. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1268-8 · Cited by 288
JUBRAN, A., MATHRU, M., DRIES, D., & TOBIN, M. J. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.6.9804056 · Cited by 276
Weaning Patients from the Ventilator
McConville, J. F., & Kress, J. P. (2012) · New England Journal of Medicine · doi:10.1056/nejmra1203367 · Cited by 270
World Interactive Network Focused On Critical UltraSound ECHO-ICU Group, Price, S., Via, G., Sloth, E., Guarracino, F., Breitkreutz, R., Catena, E., & Talmor, D. (2008) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-6-49 · Cited by 255
Etiology of extubation failure and the predictive value of the rapid shallow breathing index.
Epstein, S. K. (1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.152.2.7633705 · Cited by 252
Diaphragm and Lung Ultrasound to Predict Weaning Outcome
Llamas-Álvarez, A. M., Tenza-Lozano, E. M., & Latour-Pérez, J. (2017) · Chest · doi:10.1016/j.chest.2017.08.028 · Cited by 243
Clinical review: The ABC of weaning failure - a structured approach
Heunks, L. M., & van der Hoeven, J. G. (2010) · Critical Care · doi:10.1186/cc9296 · Cited by 220
“Moreover, in diffi cult-weaning patients with COPD and a history of heart disease, spontaneousbreathing trials resulted in elevated pulmonary artery occlusion pressure and left ventricular end diastolic pressure, suggesting reduced ventricular compliance [31].”
Physiological comparison of three spontaneous breathing trials in difficult-to-wean patients
Cabello, B., Thille, A. W., Roche-Campo, F., Brochard, L., Gómez, F. J., & Mancebo, J. (2010) · Intensive Care Medicine · doi:10.1007/s00134-010-1870-0 · Cited by 218
“Effects of PEEP and role of LVHF We found that more patients succeeded the PS trial when a PEEP of 5 cmH2O was added.”
BackgroundInfluentialRapid Shallow Breathing (Frequency-Tidal Volume Ratio) Did Not Predict Extubation Outcome
Lee, K. H., Hui, K. P., Chan, T. B., Tan, W. C., & Lim, T. K. (1994) · Chest · doi:10.1378/chest.105.2.540 · Cited by 208
Weaning from the ventilator and extubation in ICU
Thille, A. W., Cortés-Puch, I., & Esteban, A. (2013) · Current Opinion in Critical Care · doi:10.1097/mcc.0b013e32835c5095 · Cited by 205
“Switching from mechanical to spontaneous ventilation can unmask latent left ventricular heart failure [19] by increasing preload and afterload [20].”
BackgroundExtravascular lung water in critical care: recent advances and clinical applications
Jozwiak, M., Teboul, J.-L., & Monnet, X. (2015) · Annals of Intensive Care · doi:10.1186/s13613-015-0081-9 · Cited by 203
Self-citationThe hemodynamic consequences of mechanical ventilation: an evolving story
Pinsky, M. R. (1997) · Intensive Care Medicine · doi:10.1007/s001340050364 · Cited by 202
“, ITP-induced LV failure can occur immediately (< 5 min) upon cessation of ventilatory support in patients with LV dysfunction [78].”
BackgroundConsensus conference on mechanical ventilation-January 28–30, 1993 at Northbrook, Illinois, USA
Slutsky, A. S. (1994) · Intensive Care Medicine · doi:10.1007/bf01707673 · Cited by 193
Fluid balance and weaning outcomes
Upadya, A., Tilluckdharry, L., Muralidharan, V., Amoateng-Adjepong, Y., & Manthous, C. A. (2005) · Intensive Care Medicine · doi:10.1007/s00134-005-2801-3 · Cited by 183
“genic complications to reduce the duration of respiratory failure [ 7 , 8].”
BackgroundLamia, B., Maizel, J., Ochagavia, A., Chemla, D., Osman, D., Richard, C., & Teboul, J.-L. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e31819f13d0 · Cited by 178
“) that predominantly contributed to weaning failure from cardiac origin, as it was previously done by Lemaire et al (1).”
BackgroundResultInfluentialSelf-citationNatriuretic Peptide–driven Fluid Management during Ventilator Weaning: A Randomized Controlled Trial
Dessap, A. M., Roche-Campo, F., Kouatchet, A., Tomicic, V., Beduneau, G., Sonneville, R., Cabello, B., Jaber, S., Azoulay, E., Castanares-Zapatero, D., et al. (2012) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201205-0939oc · Cited by 177
Clinical challenges in mechanical ventilation
Goligher, E. C., Ferguson, N. D., & Brochard, L. J. (2016) · The Lancet · doi:10.1016/s0140-6736(16)30176-3 · Cited by 169
Spadaro, S., Grasso, S., Mauri, T., Dalla Corte, F., Alvisi, V., Ragazzi, R., Cricca, V., Biondi, G., Di Mussi, R., Marangoni, E., et al. (2016) · Critical Care · doi:10.1186/s13054-016-1479-y · Cited by 163
Clinical review: Respiratory monitoring in the ICU - a consensus of 16
Brochard, L., Martin, G. S., Blanch, L., Pelosi, P., Belda, F. J., Jubran, A., Gattinoni, L., Mancebo, J., Ranieri, V. M., Richard, J.-C. M., et al. (2012) · Critical Care · doi:10.1186/cc11146 · Cited by 160
“Decreased pleural pressure has been shown to be associated with cardiovascular failure during weaning [74], possibly because of increased transdiaphrag matic pressure and right heart overload [75].”
BackgroundIntrinsic PEEP and cardiopulmonary interaction in patients with COPD and acute ventilatory failure
Ranieri, V., Dambrosio, M., & Brienza, N. (1996) · European Respiratory Journal · doi:10.1183/09031936.96.09061283 · Cited by 85
Thoracic fluid content: A novel parameter for predicting failed weaning from mechanical ventilation
Fathy, S., Hasanin, A. M., Raafat, M., Mostafa, M. M. A., Fetouh, A. M., Elsayed, M., Badr, E. M., Kamal, H. M., & Fouad, A. Z. (2020) · Journal of Intensive Care · doi:10.1186/s40560-020-00439-2 · Cited by 36
Metadata
- Authors
- Lemaire, F., Teboul, J.-L., Cinotti, L., Giotto, G., Abrouk, F., Steg, G., Macquin-Mavier, I., & Zapol, W. M.
- Venue
- Anesthesiology
- Published
- 1988-08-01
- Volume
- 69
- Issue
- 2
- Pages
- 171-179
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2142912657
- Cited by
- 570
- References
- 0
- FWCI
- 14.62
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.