Randomized Evaluation of Pulse Oximetry in 20,802 Patients; II: Perioperative Events and Postoperative Complications
Open accessThe DOI matches its Crossref record.
Abstract
BACKGROUND: The authors describe the effect of pulse oximetry monitoring on the frequency of unanticipated perioperative events, changes in patient care, and the rate of postoperative complications in a prospective randomized study. METHODS: The study included 20,802 surgical patients in Denmark randomly assigned to be monitored or not with pulse oximetry in the operating room (OR) and postanesthesia care unit (PACU). RESULTS: During anesthesia and in the PACU, significantly more patients in the oximetry group had at least one respiratory event than did the control patients. This was the result of a 19-fold increase in the incidence of diagnosed hypoxemia in the oximetry group than in the control group in both the OR and PACU (P < 0.00001). In the OR, cardiovascular events were observed in a similar number of patients in both groups, except myocardial ischemia (as defined by angina or ST-segment depression), which was detected in 12 patients in the oximetry group and in 26 patients in the control group (P < 0.03). Several changes in PACU care were observed in association with the use of pulse oximetry. These included higher flow rate of supplemental oxygen (P < 0.00001), increased use of supplemental oxygen at discharge (P < 0.00001), and increased use of naloxone (P < 0.02). The rate of changes in patient care as a consequence of the oximetry monitoring increased as the American Society of Anesthesiologists physical status worsened (P < 0.00001). One or more postoperative complications occurred in 10% of the patients in the oximetry group and in 9.4% in the control group (difference not significant). The two groups did not differ significantly in cardiovascular, respiratory, neurologic, or infectious complications. The duration of hospital stay was a median of 5 days in both groups (difference not significant). An equal number of inhospital deaths were registered in the two groups. Questionnaires, completed by the anesthesiologists at the five participating departments, revealed that 18% of the anesthesiologists had experienced a situation in which a pulse oximeter helped to avoid a serious event or complication and that 80% of the anesthesiologists felt more secure when they used a pulse oximeter. CONCLUSIONS: This study demonstrated that pulse oximetry can improve the anesthesiologist's ability to detect hypoxemia and related events in the OR and PACU and that the use of the oximeter was associated with a significant decrease in the rate of myocardial ischemia. Although monitoring with pulse oximetry prompted a number of changes in patient care, a reduction in the overall rate of postoperative complications was not observed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Multimodal approach to control postoperative pathophysiology and rehabilitation
Kehlet, H. (1997) · British Journal of Anaesthesia · doi:10.1093/bja/78.5.606 · Cited by 2,827
Long-term postoperative cognitive dysfunction in the elderly: ISPOCD1 study
Moller, J., Cluitmans, P., Rasmussen, L., Houx, P., Rasmussen, H., Canet, J., Rabbitt, P., Jolles, J., Larsen, K., Hanning, C., et al. (1998) · The Lancet · doi:10.1016/s0140-6736(97)07382-0 · Cited by 2,422
Self-citationBTS guideline for emergency oxygen use in adult patients
O'Driscoll, B. R., Howard, L. S., Davison, A. G., & on behalf of the British Thoracic Society (2008) · Thorax · doi:10.1136/thx.2008.102947 · Cited by 729
Bhananker, S. M., Ramamoorthy, C., Geiduschek, J. M., Posner, K. L., Domino, K. B., Haberkern, C. M., Campos, J. S., & Morray, J. P. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000268712.00756.dd · Cited by 720
BTS guideline for oxygen use in adults in healthcare and emergency settings
O'Driscoll, B. R., Howard, L. S., Earis, J., & Mak, V (2017) · Thorax · doi:10.1136/thoraxjnl-2016-209729 · Cited by 679
Jubran, A. (2015) · Critical Care · doi:10.1186/s13054-015-0984-8 · Cited by 491
Cardiac Complications in Patients Undergoing Major Noncardiac Surgery
Devereaux, P. J., & Sessler, D. I. (2015) · New England Journal of Medicine · doi:10.1056/nejmra1502824 · Cited by 481
Jubran, A. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2399-x · Cited by 401
Impact of Anesthesia Management Characteristics on Severe Morbidity and Mortality
Arbous, M. S., Meursing, A. E. E., van Kleef, J. W., de Lange, J. J., Spoormans, H. H. A. J. M., Touw, P., Werner, F. M., & Grobbee, D. E. (2005) · Anesthesiology · doi:10.1097/00000542-200502000-00005 · Cited by 388
DeVita, M. A., Smith, G. B., Adam, S. K., Adams-Pizarro, I., Buist, M., Bellomo, R., Bonello, R., Cerchiari, E., Farlow, B., Goldsmith, D., et al. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2009.12.008 · Cited by 366
Sanders, R. D., Hughes, F., Shaw, A., Thompson, A., Bader, A., Hoeft, A., Williams, D. A., Grocott, M. P. W., Mythen, M. G., Miller, T. E., et al. (2019) · British Journal of Anaesthesia · doi:10.1016/j.bja.2019.01.018 · Cited by 346
Respiratory complications associated with tracheal intubation and extubation
Asai, T., Koga, K., & Vaughan, R. S. (1998) · British Journal of Anaesthesia · doi:10.1093/bja/80.6.767 · Cited by 339
Update on Bispectral Index monitoring
Johansen, J. W. (2006) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2005.08.004 · Cited by 313
Bennett-Guerrero, E., Welsby, I., Dunn, T. J., Young, L. R., Wahl, T. A., Diers, T. L., Phillips-Bute, B. G., Newman, M. F., & Mythen, M. G. (1999) · Anesthesia & Analgesia · doi:10.1097/00000539-199908000-00050 · Cited by 309
Trends in Anesthesia-related Death and Brain Damage: A Closed Claims Analysis
Cheney, F. W., Posner, K. L., Lee, L. A., Caplan, R. A., & Domino, K. B. (2006) · Anesthesiology · doi:10.1097/00000542-200612000-00007 · Cited by 286
Romero, L. M., & Remage-Healey, L. (2000) · General and Comparative Endocrinology · doi:10.1006/gcen.2000.7491 · Cited by 259
Kim, M. B., Ward, D. S., Cartwright, C. R., Kolano, J., Chlebowski, S., & Henson, L. C. (2000) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1009940031063 · Cited by 244
“In fact, the e¡ect of monitors on changing outcomes has been particularly di¤cult to show, as has been demonstrated in studies of pulse oximetry [22] and pulmonary artery catheters [3].”
Meta-analysis of arterial oxygen saturation monitoring by pulse oximetry in adults
Jensen, L. A., Onyskiw, J. E., & Prasad, N. G. N. (1998) · Heart & Lung · doi:10.1016/s0147-9563(98)90086-3 · Cited by 243
Clinicians’ abilities to estimate cardiac index in ventilated children and infants
Tibby, S. M., Hatherill, M., Marsh, M. J., & Murdoch, I. A. (1997) · Archives of Disease in Childhood · doi:10.1136/adc.77.6.516 · Cited by 224
“but this does not necessarily mean that cardiac index and other variables should not be optimised to meet the metabolic needs of individual patients. This same logic can apply to less invasive monitoring procedures such as pulse oximetry. It has been shown that monitoring with pulse oximetry in the perioperative perio…”
BackgroundSignal processing methods for pulse oximetry
Rusch, T. L., Sankar, R., & Scharf, J. E. (1996) · Computers in Biology and Medicine · doi:10.1016/0010-4825(95)00049-6 · Cited by 185
Sanborn, K. V., Castro, J., Kuroda, M., & Thys, D. M. (1996) · Anesthesiology · doi:10.1097/00000542-199611000-00004 · Cited by 176
Original Investigations of Anesthetic Practice
Watcha, M. F., & White, P. F. (1997) · Anesthesiology · doi:10.1097/00000542-199705000-00021 · Cited by 168
Effective hemodynamic monitoring
Pinsky, M. R., Cecconi, M., Chew, M. S., De Backer, D., Douglas, I., Edwards, M., Hamzaoui, O., Hernandez, G., Martin, G., Monnet, X., et al. (2022) · Critical Care · doi:10.1186/s13054-022-04173-z · Cited by 167
Clinical review: Respiratory monitoring in the ICU - a consensus of 16
Brochard, L., Martin, G. S., Blanch, L., Pelosi, P., Belda, F. J., Jubran, A., Gattinoni, L., Mancebo, J., Ranieri, V. M., Richard, J.-C. M., et al. (2012) · Critical Care · doi:10.1186/cc11146 · Cited by 160
“In a randomized controlled trial in more than 20,000 surgical patients [5], pulse oximetry was not associated with decreased postoperative complications or mortality, but 80% of the anesthesiologists felt more secure when a pulse oximeter was used! Transcutaneous partial pressure of carbon dioxide (PCO2) monitors have…”
BackgroundNilsson, L., Goscinski, T., Kalman, S., Lindberg, L. ‐., & Johansson, A. (2007) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2007.01375.x · Cited by 88
Metadata
- Authors
- Moller, J. T., Johannessen, N. W., Espersen, K., Ravlo, O., Pedersen, B. D., Jensen, P. F., Rasmussen, N. H., Rasmussen, L. S., Pedersen, T., Cooper, J. B., Gravenstein, J. S., Chraemmer-Jørgensen, B., Djernes, M., Wiberg-Jørgensen, F., Heslet, L., & Johansen, S. H.
- Venue
- Anesthesiology
- Published
- 1993-03-01
- Volume
- 78
- Issue
- 3
- Pages
- 445-453
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2098506383
- Cited by
- 435
- References
- 0
- FWCI
- 15.56
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.