Electroencephalographic Derivatives as a Tool for Predicting the Depth of Sedation and Anesthesia Induced by Sevoflurane
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Background: The electroencephalogram (EEG) has been evaluated as a tool for measuring depth of anesthesia, but the use of the EEG monitoring is still controversial. The current study was designed to evaluate the accuracy of three EEG parameters and anesthetic concentration for predicting depth of sedation and anesthesia during sevoflurane anesthesia Methods: One low and one high equilibrated concentration ranging from 0.2-1.8% were assigned randomly and administered consecutively to 69 patients. The bispectral index (BIS; version 3.2), 95% spectral edge frequency (SEF), and median power frequency (MPF) were obtained from a bipolar frontomastoid (Fp1-A1, Fp2-A2) montage using an EEG monitor. Sedation was assessed using the responsiveness portion of the observer's assessment of alertness-sedation scale. In the second phase of the study, the 47 patients who were scheduled to have skin incisions were observed for purposeful movement in response to skin incision at sevoflurane concentrations between 1.6% and 2.4%. The relation among BIS, 95% SEF, MPF, sevoflurane concentration, sedation score, and movement or no movement after skin incision, was determined. Prediction probability values for EEG parameters and sevoflurane concentration to predict depth of sedation and anesthesia were also calculated. Results: The BIS and sevoflurane concentration correlated closely with the sedation score. Both 95% SEF and MPF changed significantly but biphasically with increasing sedation. The prediction probability values for BIS and sevoflurane concentration were 0.966 and 0.945, respectively, indicating a high predictive performance for depth of sedation. No EEG parameters predicted movement after skin incision better than chance alone. Conclusions: Parameters derived from EEG, such as BIS, and 95% SEF are reliable guides to the depth of sedation, but not to the adequacy of anesthesia level for preventing movement during sevoflurane anesthesia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Glass, P. S., Bloom, M., Kearse, L., Rosow, C., Sebel, P., & Manberg, P. (1997) · Anesthesiology · doi:10.1097/00000542-199704000-00014 · Cited by 1,274
Validity and Reliability of the Observer??s: Assessment of Alertness/Sedation Scale
CHERNIK, D. A., GILLINGS, D., LAINE, H., HENDLER, J., SILVER, J. M., DAVIDSON, A. B., SCHWAM, E. M., & SIEGEL, J. L. (1990) · Journal of Clinical Psychopharmacology · doi:10.1097/00004714-199008000-00003 · Cited by 1,246
An introduction to bispectral analysis for the electroencephalogram
Sigl, J. C., & Chamoun, N. G. (1994) · Journal of Clinical Monitoring · doi:10.1007/bf01618421 · Cited by 804
Anesthetic Potency (MAC) Is Independent of Forebrain Structures in the Rat
Rampil, I. J., Mason, P., & Singh, H. (1993) · Anesthesiology · doi:10.1097/00000542-199304000-00014 · Cited by 521
Exaggerated Anesthetic Requirements in the Preferentially Anesthetized Brain
Antognini, J. F., & Schwartz, K. (1993) · Anesthesiology · doi:10.1097/00000542-199312000-00015 · Cited by 506
Measuring the Performance of Anesthetic Depth Indicators
Smith, W. D., Dutton, R. C., & Smith, T. N. (1996) · Anesthesiology · doi:10.1097/00000542-199601000-00005 · Cited by 418
A Multicenter Study of Bispectral Electroencephalogram Analysis for Monitoring Anesthetic Effect
Sebel, P. S., Lang, E., Rampil, I. J., White, P. F., Cork, R., Jopling, M., Smith, N. T., Glass, P. S. A., & Manberg, P. (1997) · Anesthesia & Analgesia · doi:10.1213/00000539-199704000-00035 · Cited by 302
The Minimum Alveolar Concentration (MAC) of Sevoflurane in Humans
Katoh, T., & Ikeda, K. (1987) · Anesthesiology · doi:10.1097/00000542-198703000-00006 · Cited by 278
Self-citationON BIOLOGICAL ASSAYS INVOLVING QUANTAL RESPONSES
WAUD, D. R. (1972) · The Journal of Pharmacology and Experimental Therapeutics · doi:10.1016/s0022-3565(25)29374-0 · Cited by 242
Vernon, J. M., Lang, E. J., Sebel, P. S., & Manberg, P. J. (1995) · Anesthesia & Analgesia · doi:10.1213/00000539-199504000-00023 · Cited by 222
MAC of sevoflurane in humans and the New Zealand white rabbit
Scheller, M. S., Saidman, L. J., & Partridge, B. L. (1988) · Canadian Journal of Anaesthesia · doi:10.1007/bf03010656 · Cited by 219
Kearse, L. A., Manberg, P., Chamoun, N., deBros, F., & Zaslavsky, A. (1994) · Anesthesiology · doi:10.1097/00000542-199412000-00010 · Cited by 212
Rampil, I. J., & Matteo, R. S. (1987) · Anesthesiology · doi:10.1097/00000542-198707000-00033 · Cited by 173
Does the Brain Influence Somatic Responses to Noxious Stimuli during Isoflurane Anesthesia?
Borges, M., & Antognini, J. F. (1994) · Anesthesiology · doi:10.1097/00000542-199412000-00027 · Cited by 134
The Electroencephalogram Does Not Predict Depth of Isoflurane Anesthesia
Dwyer, R. C., Rampil, I. J., Eger, E. I., & Bennett, H. L. (1994) · Anesthesiology · doi:10.1097/00000542-199408000-00019 · Cited by 129
Influence of age on awakening concentrations of sevoflurane and isoflurane.
Katoh, T., Suguro, Y., Ikeda, T., Kazama, T., & Ikeda, K. (1993) · PubMed · Cited by 101
Self-citationEEG AND MEMORY EFFECTS OF LOW-DOSE INFUSIONS OF PROPOFOL †
Veselis, R. A., Reinsel, R. A., Wroński, M., Marino, P., TONG, W. P., & Bedford, R. F. (1992) · British Journal of Anaesthesia · doi:10.1093/bja/69.3.246 · Cited by 94
Katoh, T., Suguro, Y., Kimura, T., & Ikeda, K. (1993) · Anesthesia & Analgesia · doi:10.1213/00000539-199311000-00024 · Cited by 69
Self-citationTolerance to alprazolam after intravenous bolus and continuous infusion: Psychomotor and EEG effects
Kroboth, P. D., Smith, R. B., & Erb, R. J. (1988) · Clinical Pharmacology & Therapeutics · doi:10.1038/clpt.1988.32 · Cited by 57
Awareness detection during Caesarean section under general anaesthesia using EEG spectrum analysis
Gaitini, L. A., Vaida, S. J., Collins, G., Somri, M., & Sabo, E. (1995) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03015480 · Cited by 21
Cited by
Development and Clinical Application of Electroencephalographic Bispectrum Monitoring
Johansen, J. W., Sebel, P. S., & Fisher, D. M. (2000) · Anesthesiology · doi:10.1097/00000542-200011000-00029 · Cited by 599
Hans, P., Dewandre, P.-Y., Brichant, J. F., & Bonhomme, V. (2005) · British Journal of Anaesthesia · doi:10.1093/bja/aei047 · Cited by 271
The Bispectral Index Declines During Neuromuscular Block in Fully Awake Persons
Messner, M., Beese, U., Romstöck, J., Dinkel, M., & Tschaikowsky, A. K. (2003) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000072741.78244.c0 · Cited by 261
Bispectral Index Monitoring during Sedation with Sevoflurane, Midazolam, and Propofol
Ibrahim, A. E., Taraday, J. K., & Kharasch, E. D. (2001) · Anesthesiology · doi:10.1097/00000542-200111000-00019 · Cited by 259
Struys, M. M. R. F., Jensen, E. W., Smith, W., Smith, N. T., Rampil, I., Dumortier, F. J. E., Mestach, C., & Mortier, E. P. (2002) · Anesthesiology · doi:10.1097/00000542-200204000-00006 · Cited by 223
“Our findings agree with those previously found for propofol,(27) as well as the previously published observations between utility of BIS and measured sevoflurane or isoflurane end-tidal concentration.(21,26) This highly predictive accuracy of drug effect-site concentrations has Fig.”
BackgroundResult
Metadata
- Authors
- Katoh, T., Suzuki, A., & Ikeda, K.
- Venue
- Anesthesiology
- Published
- 1998-03-01
- Volume
- 88
- Issue
- 3
- Pages
- 642-650
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2085794477
- Cited by
- 333
- References
- 20
- FWCI
- 19.71
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.