Changes in Arterial Pressure during Mechanical Ventilation
Open accessThe DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Abstract
Mechanical ventilation induces cyclic changes in vena cava blood flow, pulmonary artery blood flow, and aortic blood flow. At the bedside, respiratory changes in aortic blood flow are reflected by "swings" in blood pressure whose magnitude is highly dependent on volume status. During the past few years, many studies have demonstrated that arterial pressure variation is neither an indicator of blood volume nor a marker of cardiac preload but a predictor of fluid responsiveness. That is, these studies have demonstrated the value of this physical sign in answering one of the most common clinical questions, Can we use fluid to improve hemodynamics?, while static indicators of cardiac preload (cardiac filling pressures but also cardiac dimensions) are frequently unable to correctly answer this crucial question. The reliable analysis of respiratory changes in arterial pressure is possible in most patients undergoing surgery and in critically ill patients who are sedated and mechanically ventilated with conventional tidal volumes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Boldt, J., Lenz, M., Kumle, B., et al. (1998) · Intensive Care Medicine · doi:10.1007/s001340050536 · Cited by 148
Retracted(2000) · New England Journal of Medicine · doi:10.1056/nejm200005043421801 · Cited by 12,941
Kress, J. P., Pohlman, A. S., O'Connor, M. F., & Hall, J. B. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005183422002 · Cited by 2,981
The Effectiveness of Right Heart Catheterization in the Initial Care of Critically III Patients
Connors, A. F. (1996) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1996.03540110043030 · Cited by 2,210
Sandham, J. D., Hull, R. D., Brant, R. F., Knox, L., Pineo, G. F., Doig, C. J., Laporta, D. P., Viner, S., Passerini, L., Devitt, H., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa021108 · Cited by 1,529
MICHARD, F., BOUSSAT, S., CHEMLA, D., ANGUEL, N., MERCAT, A., LECARPENTIER, Y., RICHARD, C., PINSKY, M. R., & TEBOUL, J.-L. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.1.9903035 · Cited by 1,458
Self-citationPredicting Fluid Responsiveness in ICU Patients
Michard, F., & Teboul, J.-L. (2002) · Chest · doi:10.1378/chest.121.6.2000 · Cited by 1,367
Self-citationDistribution of blood flow in isolated lung; relation to vascular and alveolar pressures
West, J. B., Dollery, C. T., & Naimark, A. (1964) · Journal of Applied Physiology · doi:10.1152/jappl.1964.19.4.713 · Cited by 1,107
The respiratory variation in inferior vena cava diameter as a guide to fluid therapy
Feissel, M., Michard, F., Faller, J.-P., & Teboul, J.-L. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2233-5 · Cited by 967
Self-citationKumar, A., Anel, R., Bunnell, E., Habet, K., Zanotti, S., Marshall, S., Neumann, A., Ali, A., Cheang, M., Kavinsky, C., et al. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000114996.68110.c9 · Cited by 800
Cited by
Venous Function and Central Venous Pressure: A Physiologic Story
Gelman, S., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e3181672607 · Cited by 575
Cannesson, M., Le Manach, Y., Hofer, C. K., Goarin, J. P., Lehot, J.-J., Vallet, B., & Tavernier, B. (2011) · Anesthesiology · doi:10.1097/aln.0b013e318225b80a · Cited by 554
Photoplethysmography: Beyond the Calculation of Arterial Oxygen Saturation and Heart Rate
Shelley, K. H. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000269512.82836.c9 · Cited by 450
Lopes, M. R., Oliveira, M. A., Pereira, V. O. S., Lemos, I. P. B., Auler, J. O. C., & Michard, F. (2007) · Critical Care · doi:10.1186/cc6117 · Cited by 442
Self-citationMuller, L., Bobbia, X., Toumi, M., Louart, G., Molinari, N., Ragonnet, B., Quintard, H., Leone, M., Zoric, L., Lefrant, J. Y., et al. (2012) · Critical Care · doi:10.1186/cc11672 · Cited by 374
Muller, L., Toumi, M., Bousquet, P.-J., Riu-Poulenc, B., Louart, G., Candela, D., Zoric, L., Suehs, C., de La Coussaye, J.-E., Molinari, N., et al. (2011) · Anesthesiology · doi:10.1097/aln.0b013e318229a500 · Cited by 343
Perioperative fluid therapy: a statement from the international Fluid Optimization Group
Navarro, L. H. C., Bloomstone, J. A., Auler, J. O. C., Cannesson, M., Rocca, G. D., Gan, T. J., Kinsky, M., Magder, S., Miller, T. E., Mythen, M., et al. (2015) · Perioperative Medicine · doi:10.1186/s13741-015-0014-z · Cited by 298
Alian, A. A., & Shelley, K. H. (2014) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2014.08.006 · Cited by 289
“Variations in arterial pulse pressure (∆PP) [32], vena cava diameter [33], stroke volume (SVV) [34], and aortic blood flow [35] have been shown to be more accurate predictors of fluid responsiveness.”
BackgroundBenes, J., Giglio, M., Brienza, N., & Michard, F. (2014) · Critical Care · doi:10.1186/s13054-014-0584-z · Cited by 257
Self-citationPredicting Fluid Responsiveness in Children: A Systematic Review
Gan, H., Cannesson, M., Chandler, J. R., & Ansermino, J. M. (2013) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3182a9557e · Cited by 226
Cannesson, M., Musard, H., Desebbe, O., Boucau, C., Simon, R., Hénaine, R., & Lehot, J.-J. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318192a36b · Cited by 214
“During positive pressure ventilation, the inspiratory right ventricular stroke volume (SV) decrease is proportional to the degree of hypovolemia and is transmitted to the left heart after two or three beats (pulmonary transit time).(6,7) A recent study suggested that intraoperative goaldirected therapy based on the op…”
BackgroundFutier, E., Constantin, J.-M., Pelosi, P., Chanques, G., Massone, A., Petit, A., Kwiatkowski, F., Bazin, J.-E., & Jaber, S. (2011) · Anesthesiology · doi:10.1097/aln.0b013e31821811ba · Cited by 212
“4/6%; Voluven, Fresenius Kabi, Bad Hamburg, Germany) were given to maintain pulse pressure variation less than 13%.(18) Anesthetists with sufficient experience in the management of morbidly obese patients performed all anesthesia procedures.”
BackgroundNoury, N., Hipp, J. F., & Siegel, M. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.03.065 · Cited by 180
“Indeed, variations of blood volume in vessels caused by heartbeat and respiration, rhythmically modulate body impedance, a phenomenon that is used in impedance plethysmography to monitor cardiodynamic parameters (Dornhorst et al., 1952; Kristiansen et al., 2005; Michard, 2005; Nyboer et al., 1950).”
BackgroundNon-invasive prediction of fluid responsiveness during major hepatic surgery † ‡
Solus-Biguenet, H., Fleyfel, M., Tavernier, B., Kipnis, E., Onimus, J., Robin, E., Lebuffe, G., Decoene, C., Pruvot, F. R., & Vallet, B. (2006) · British Journal of Anaesthesia · doi:10.1093/bja/ael250 · Cited by 169
Functional Hemodynamic Monitoring
Pinsky, M. R. (2015) · Critical Care Clinics · doi:10.1016/j.ccc.2014.08.005 · Cited by 168
“Several clinical trials have documented that a SVV >10% or a PPV >13-15% on a tidal volume of ≥8 ml/kg or greater is highly predictive of volume responsiveness [45,46,47].”
Background
Metadata
- Authors
- Michard, F.
- Venue
- Anesthesiology
- Published
- 2005-08-01
- Volume
- 103
- Issue
- 2
- Pages
- 419-428
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W1950399482
- Cited by
- 713
- References
- 52
- FWCI
- 28.24
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.