Changes in Arterial Pressure during Mechanical Ventilation
Open accessThe DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Abstract
Mechanical ventilation induces cyclic changes in vena cava blood flow, pulmonary artery blood flow, and aortic blood flow. At the bedside, respiratory changes in aortic blood flow are reflected by "swings" in blood pressure whose magnitude is highly dependent on volume status. During the past few years, many studies have demonstrated that arterial pressure variation is neither an indicator of blood volume nor a marker of cardiac preload but a predictor of fluid responsiveness. That is, these studies have demonstrated the value of this physical sign in answering one of the most common clinical questions, Can we use fluid to improve hemodynamics?, while static indicators of cardiac preload (cardiac filling pressures but also cardiac dimensions) are frequently unable to correctly answer this crucial question. The reliable analysis of respiratory changes in arterial pressure is possible in most patients undergoing surgery and in critically ill patients who are sedated and mechanically ventilated with conventional tidal volumes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Boldt, J., Lenz, M., Kumle, B., et al. (1998) · Intensive Care Medicine · doi:10.1007/s001340050536 · Cited by 148
Retracted(2000) · New England Journal of Medicine · doi:10.1056/nejm200005043421801 · Cited by 12,941
Kress, J. P., Pohlman, A. S., O'Connor, M. F., & Hall, J. B. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005183422002 · Cited by 2,981
The Effectiveness of Right Heart Catheterization in the Initial Care of Critically III Patients
Connors, A. F. (1996) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1996.03540110043030 · Cited by 2,210
Sandham, J. D., Hull, R. D., Brant, R. F., Knox, L., Pineo, G. F., Doig, C. J., Laporta, D. P., Viner, S., Passerini, L., Devitt, H., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa021108 · Cited by 1,529
MICHARD, F., BOUSSAT, S., CHEMLA, D., ANGUEL, N., MERCAT, A., LECARPENTIER, Y., RICHARD, C., PINSKY, M. R., & TEBOUL, J.-L. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.1.9903035 · Cited by 1,458
Self-citationPredicting Fluid Responsiveness in ICU Patients
Michard, F., & Teboul, J.-L. (2002) · Chest · doi:10.1378/chest.121.6.2000 · Cited by 1,367
Self-citationDistribution of blood flow in isolated lung; relation to vascular and alveolar pressures
West, J. B., Dollery, C. T., & Naimark, A. (1964) · Journal of Applied Physiology · doi:10.1152/jappl.1964.19.4.713 · Cited by 1,107
The respiratory variation in inferior vena cava diameter as a guide to fluid therapy
Feissel, M., Michard, F., Faller, J.-P., & Teboul, J.-L. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2233-5 · Cited by 967
Self-citationKumar, A., Anel, R., Bunnell, E., Habet, K., Zanotti, S., Marshall, S., Neumann, A., Ali, A., Cheang, M., Kavinsky, C., et al. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000114996.68110.c9 · Cited by 800
PUTENSEN, C., ZECH, S., WRIGGE, H., ZINSERLING, J., STÜBER, F., VON SPIEGEL, T., & MUTZ, N. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.1.2001078 · Cited by 638
Feissel, M., Michard, F., Mangin, I., Ruyer, O., Faller, J.-P., & Teboul, J.-L. (2001) · CHEST · doi:10.1378/chest.119.3.867 · Cited by 612
Self-citationSystolic Pressure Variation as a Guide to Fluid Therapy in Patients with Sepsis-induced Hypotension
Tavernier, B., Makhotine, O., Lebuffe, G., Dupont, J., & Scherpereel, P. (1998) · Anesthesiology · doi:10.1097/00000542-199812000-00007 · Cited by 570
Venous Return at Various Right Atrial Pressures and the Normal Venous Return Curve
Guyton, A. C., Lindsey, A. W., Abernathy, B., & Richardson, T. (1957) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1957.189.3.609 · Cited by 544
Direct Blood Pressure Measurement —Dynamic Response Requirements
Gardner, R. M. (1981) · Anesthesiology · doi:10.1097/00000542-198103000-00010 · Cited by 518
Superior vena caval collapsibility as a gauge of volume status in ventilated septic patients
Vieillard-Baron, A., Chergui, K., Rabiller, A., Peyrouset, O., Page, B., Beauchet, A., & Jardin, F. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2361-y · Cited by 476
Total arterial compliance estimated by stroke volume-to-aortic pulse pressure ratio in humans
Chemla, D., Hébert, J.-L., Coirault, C., Zamani, K., Suard, I., Colin, P., & Lecarpentier, Y. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.274.2.h500 · Cited by 462
Eichacker, P. Q., Gerstenberger, E. P., Banks, S. M., Cui, X., & Natanson, C. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200208-956oc · Cited by 423
Stroke Volume Variation as a Predictor of Fluid Responsiveness in Patients Undergoing Brain Surgery
Berkenstadt, H., Margalit, N., Hadani, M., Friedman, Z., Segal, E., Villa, Y., & Perel, A. (2001) · Anesthesia & Analgesia · doi:10.1097/00000539-200104000-00034 · Cited by 412
Perel, A., Pizov, R., & Cotev, S. (1987) · Anesthesiology · doi:10.1097/00000542-198710000-00009 · Cited by 403
Reuter, D. A., Felbinger, T. W., Schmidt, C., et al. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1211-z · Cited by 375
MICHARD, F., CHEMLA, D., RICHARD, C., WYSOCKI, M., PINSKY, M. R., LECARPENTIER, Y., & TEBOUL, J.-L. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.3.9805077 · Cited by 371
Self-citationFluid responsiveness in mechanically ventilated patients: a review of indices used in intensive care
Bendjelid, K., & Romand, J.-A. (2003) · Intensive Care Medicine · doi:10.1007/s00134-002-1615-9 · Cited by 366
Short‐term cardiovascular oscillations in man: measuring and modelling the physiologies
Cohen, M. A., & Taylor, J. A. (2002) · The Journal of Physiology · doi:10.1113/jphysiol.2002.017483 · Cited by 362
Global End-Diastolic Volume as an Indicator of Cardiac Preload in Patients With Septic Shock *
Michard, F., Alaya, S., Zarka, V., Bahloul, M., Richard, C., & Teboul, J.-L. (2003) · Chest · doi:10.1378/chest.124.5.1900 · Cited by 352
Self-citationReliability of clinical monitoring to assess blood volume in critically ill patients
SHIPPY, C. R., APPEL, P. L., & SHOEMAKER, W. C. (1984) · Critical Care Medicine · doi:10.1097/00003246-198402000-00005 · Cited by 342
Cyclic changes in right ventricular output impedance during mechanical ventilation
Vieillard-Baron, A., Loubieres, Y., Schmitt, J.-M., Page, B., Dubourg, O., & Jardin, F. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.5.1644 · Cited by 303
Reuter, D. A., Kirchner, A., Felbinger, T. W., Weis, F. C., Kilger, E., Lamm, P., & Goetz, A. E. (2003) · Critical Care Medicine · doi:10.1097/01.ccm.0000059442.37548.e1 · Cited by 281
Reuter, D. A., Bayerlein, J., Goepfert, M. S. G., Weis, F. C., Kilger, E., Lamm, P., & Goetz, A. E. (2003) · Intensive Care Medicine · doi:10.1007/s00134-003-1649-7 · Cited by 265
Jardin, F., & Vieillard-Baron, A. (2003) · Intensive Care Medicine · doi:10.1007/s00134-003-1873-1 · Cited by 231
Dorman, T., Breslow, M. J., Lipsett, P. A., Rosenberg, J. M., Balser, J. R., Almog, Y., & Rosenfeld, B. A. (1998) · Critical Care Medicine · doi:10.1097/00003246-199810000-00014 · Cited by 189
Respiratory variations in right atrial pressure predict the response to fluid challenge
Magder, S. A., Georgiadis, G., & Cheong, T. H. (1992) · Journal of Critical Care · doi:10.1016/0883-9441(92)90032-3 · Cited by 188
Pulse oximetry plethysmographic waveform during changes in blood volume
Shamir, M., Eidelman, L. A., Floman, Y., Kaplan, L., & Pizov, R. (1999) · British Journal of Anaesthesia · doi:10.1093/bja/82.2.178 · Cited by 184
Cardiac variability in critically ill adults: Influence of sepsis
Korach, M., Sharshar, T., Jarrin, I., Fouillot, J.-P., Raphaël, J.-C., Gajdos, P., & Annane, D. (2001) · Critical Care Medicine · doi:10.1097/00003246-200107000-00013 · Cited by 173
Determinants of pulmonary arterial flow variation during respiration
Pinsky, M. R. (1984) · Journal of Applied Physiology · doi:10.1152/jappl.1984.56.5.1237 · Cited by 173
Respiratory variations of aortic VTI: a new index of hypovolemia and fluid responsiveness
Slama, M., Masson, H., Teboul, J.-L., Arnout, M.-L., Susic, D., Frohlich, E., & Andrejak, M. (2002) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00308.2002 · Cited by 172
Marx, G., Cope, T., McCrossan, L., Swaraj, S., Cowan, C., Mostafa, S. M., Wenstone, R., & Leuwer, M. (2004) · European Journal of Anaesthesiology · doi:10.1017/s0265021504002091 · Cited by 162
Cyclic Changes in Arterial Pulse during Respiratory Support Revisited by Doppler Echocardiography
Vieillard‐Baron, A., Chergui, K., Augarde, R., Prin, S., Page, B., Beauchet, A., & Jardin, F. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200301-135oc · Cited by 157
Clinical Usefulness of Respiratory Variations in Arterial Pressure
Magder, S. A. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200211-1360cc · Cited by 157
Systolic Blood Pressure Revisited
Smulyan, H., & Safar, M. E. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00081-8 · Cited by 136
Reuter, D. A., Felbinger, T. W., Kilger, E., Schmidt, C., Lamm, P., & Goetz, A. E. (2002) · British Journal of Anaesthesia · doi:10.1093/bja/88.1.124 · Cited by 136
Estimating cardiac filling pressure in mechanically ventilated patients with hyperinflation
Teboul, J., Pinsky, M. R., Mercat, A., Anguel, N., Bernardin, G., Achard, J., Boulain, T., & Richard, C. (2000) · Critical Care Medicine · doi:10.1097/00003246-200011000-00014 · Cited by 131
Mechanism of reduced LV afterload by systolic and diastolic positive pleural pressure
Fessler, H. E., Brower, R. G., Wise, R. A., & Permutt, S. (1988) · Journal of Applied Physiology · doi:10.1152/jappl.1988.65.3.1244 · Cited by 118
Guz, A., Innes, J. A., & Murphy, K. (1987) · The Journal of Physiology · doi:10.1113/jphysiol.1987.sp016836 · Cited by 96
Innes, J. A., De Cort, S. C., Kox, W., & Guz, A. (1993) · The Journal of Physiology · doi:10.1113/jphysiol.1993.sp019483 · Cited by 83
Monitoring of respiratory variations of aortic blood flow velocity using esophageal Doppler
Slama, M., Masson, H., Teboul, J., Arnould, M.-L., Nait-Kaoudjt, R., Colas, B., Peltier, M., Tribouilloy, C., Sušić, D., Frohlich, E. D., et al. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2190-z · Cited by 77
Influence of tidal volume on stroke volume variation. Does it really matter?
Michard, F., Teboul, J., & Richard, C. (2003) · Intensive Care Medicine · doi:10.1007/s00134-003-1886-9 · Cited by 33
Self-citationDeterminants of systolic pressure variation in patients ventilated after vascular surgery
Beaussier, M., Coriat, P., Perel, A., Bret, F. L., Kalfon, P., Chemla, D., Lienhart, A., & VIARS, P. (1995) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(05)80139-9 · Cited by 31
Buffering of respiratory variations in venous return by right ventricle: a theoretical analysis
Santamore, W. P., & Amoore, J. (1994) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1994.267.6.h2163 · Cited by 29
Venous collapse and the respiratory variability in systemic venous return
Amoore, J., & Santamore, W. P. (1994) · Cardiovascular Research · doi:10.1093/cvr/28.4.472 · Cited by 23
Morélot‐Panzini, C., Lefort, Y., Derenne, J., & Similowski, T. (2003) · CHEST Journal · doi:10.1378/chest.124.2.665 · Cited by 16
Cited by
Venous Function and Central Venous Pressure: A Physiologic Story
Gelman, S., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e3181672607 · Cited by 575
Cannesson, M., Le Manach, Y., Hofer, C. K., Goarin, J. P., Lehot, J.-J., Vallet, B., & Tavernier, B. (2011) · Anesthesiology · doi:10.1097/aln.0b013e318225b80a · Cited by 554
Photoplethysmography: Beyond the Calculation of Arterial Oxygen Saturation and Heart Rate
Shelley, K. H. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000269512.82836.c9 · Cited by 450
Lopes, M. R., Oliveira, M. A., Pereira, V. O. S., Lemos, I. P. B., Auler, J. O. C., & Michard, F. (2007) · Critical Care · doi:10.1186/cc6117 · Cited by 442
Self-citationMuller, L., Bobbia, X., Toumi, M., Louart, G., Molinari, N., Ragonnet, B., Quintard, H., Leone, M., Zoric, L., Lefrant, J. Y., et al. (2012) · Critical Care · doi:10.1186/cc11672 · Cited by 374
Metadata
- Authors
- Michard, F.
- Venue
- Anesthesiology
- Published
- 2005-08-01
- Volume
- 103
- Issue
- 2
- Pages
- 419-428
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W1950399482
- Cited by
- 713
- References
- 52
- FWCI
- 28.24
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.