Background: A new eight-wavelength pulse oximeter is designed to measure methemoglobin and carboxyhemoglobin, in addition to the usual measurements of hemoglobin oxygen saturation and pulse rate. This study examines this device's ability to measure dyshemoglobins in human volunteers in whom controlled levels of methemoglobin and carboxyhemoglobin are induced. Methods: Ten volunteers breathed 500 ppm carbon monoxide until their carboxyhemoglobin levels reached 15%, and 10 different volunteers received intravenous sodium nitrite, 300 mg, to induce methemoglobin. All were instrumented with arterial cannulas and six Masimo Rad-57 (Masimo Inc., Irvine, CA) pulse oximeter sensors. Arterial blood was analyzed by three laboratory CO-oximeters, and the resulting carboxyhemoglobin and methemoglobin measurements were compared with the corresponding pulse oximeter readings. Results: The Rad-57 measured carboxyhemoglobin with an uncertainty of +/-2% within the range of 0-15%, and it measured methemoglobin with an uncertainty of 0.5% within the range of 0-12%. Conclusion: The Masimo Rad-57 is the first commercially available pulse oximeter that can measure methemoglobin and carboxyhemoglobin, and it therefore represents an expansion of our oxygenation monitoring capability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Conventional pulse oximetry cannot distinguish between COHb and oxyHb, and, as such, can miss signi fi cant COHb levels and profound hypoxia (44).”
From Carbon monoxide poisoning: pathogenesis, management, and future directions of therapy (2017) · cites this paper as [44]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300 · cited 2×
“Bias (mean error) and precision (SD of error) were calculated as recommended by Altman and Bland.7 Linear regression was used to calculate the slope and intercept of the best fit straight line relation between the two methods.”
MethodEffects of Methemoglobinemia on Pulse Oximetry and Mixed Venous Oximetry
Barker, S. J., Tremper, K. K., & Hyatt, J. (1989) · Anesthesiology · doi:10.1097/00000542-198901000-00021 · Cited by 382 · cited 2×
“to drive the SpO2 readings toward 85%, no matter what the actual oxygen saturation.(3) In this animal study, metUS Department of Labor report on Sago Mine disaster.”
BackgroundMethodSelf-citationThe Effect of Carbon Monoxide Inhalation on Pulse Oximetry and Transcutaneous Po 2
Barker, S. J., & Tremper, K. K. (1987) · Anesthesiology · doi:10.1097/00000542-198705000-00014 · Cited by 281
Self-citationEffects of Intravenously Administered Dyes on Pulse Oximetry Readings
SCHELLER, M. S., UNGER, R. J., & KELNER, M. J. (1986) · Anesthesiology · doi:10.1097/00000542-198611000-00023 · Cited by 194
History of blood gas analysis. VII. Pulse oximetry
Severinghaus, J. W., & Honda, Y. (1987) · Journal of Clinical Monitoring · doi:10.1007/bf00858362 · Cited by 179 · cited 1×
“Since its invention by Aoyagi in 1974, the pulse oximeter has become the most common monitor of patient oxygenation.(8) However, all pulse oximeters in clinical use to date share a serious limitation.”
BackgroundThe antidotal action of sodium nitrite and sodium thiosulfate against cyanide poisoning
Baskin, S. I., Horowitz, A. M., & Nealley, E. W. (1992) · The Journal of Clinical Pharmacology · doi:10.1002/j.1552-4604.1992.tb03849.x · Cited by 165
Pulse Oximetry in Severe Carbon Monoxide Poisoning
Hampson, N. B. (1998) · CHEST Journal · doi:10.1378/chest.114.4.1036 · Cited by 145 · cited 1×
“2,3 These errors have been confirmed in clinical case reports.(4,5) No pre-”
BackgroundPulse Oximetry in Methemoglobinemia
Watcha, M. F., Connor, M. T., & Hing, A. V. (1989) · Archives of Pediatrics and Adolescent Medicine · doi:10.1001/archpedi.1989.02150190095030 · Cited by 69 · cited 1×
“2,3 These errors have been confirmed in clinical case reports.(4,5) No pre-”
BackgroundSevere Carbon Monoxide Poisoning during Desflurane Anesthesia
Berry, P. D., Sessler, D. I., & Larson, M. D. (1999) · Anesthesiology · doi:10.1097/00000542-199902000-00036 · Cited by 65 · cited 1×
“Louis, MO) has also caused serious toxicity.(11)”
Benzocaine-Induced Methemoglobinemia in an Adult: Accuracy of Pulse Oximetry with Methemoglobinemia
Anderson, S. T., Hajduczek, J., & Barker, S. J. (1988) · Anesthesia & Analgesia · doi:10.1213/00000539-198811000-00015 · Cited by 64
Self-citation
Cited by
Items 101–200 of 275
GenetiC Mechanisms Underlying Regulation of Hemoglobin Mass
Agarwal, N., Gordeuk, V. R., & Prchal, J. T. (2007) · Advances in experimental medicine and biology · doi:10.1007/978-0-387-75434-5_15 · Cited by 12
Two cases of methemoglobinemia: In a military community hospital.
Wall, L. J. L., Wong, L. J. B., Kinderknecht, L. K. J., Farrior, C. L. K., & Gabbay, D. S. (2016) · Europe PMC (PubMed Central) · Cited by 12
Multi-Wavelength Pulse Oximeter Is Not Suitable for Adjusting D LCO Measurements
Ruppel, G. L., Wilson, H. A., Gall, V. K., & Hempkens, J. A. (2011) · Respiratory Care · doi:10.4187/respcare.01142 · Cited by 11
Anesthesia implications of waterpipe use
Kesner, K. L., Ramaiah, V. K., Hemmer, L. B., & Koht, A. H. (2012) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2011.05.005 · Cited by 11
Use of bi-level pulsed frequency-division excitation for improving blood oxygen saturation precision
Song, S., Jiang, F., Hao, L., Xu, L., Yi, X., Li, G., & Lin, L. (2018) · Measurement · doi:10.1016/j.measurement.2018.07.076 · Cited by 11
Screening by pulse CO‐oximetry for environmental tobacco smoke exposure in preanesthetic children
Cardwell, K. A., Pan, Z., Boucher, R., Zuk, J., & Friesen, R. H. (2012) · Pediatric Anesthesia · doi:10.1111/j.1460-9592.2012.03867.x · Cited by 11
Wavelength Selection Method with Standard Deviation: Application to Pulse Oximetry
Vazquez-Jaccaud, C., Паез, Г., & Strojnik, M. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0304-7 · Cited by 11
Methemoglobinemia in Postchemotherapy Stomatitis Topical Treatment: 2 Pediatric Cases
Kaczorowska-Hać, B., Stefanowicz, J., Stachowicz‐Stencel, T., Kozłowska, M., Adamkiewicz‐Drożyńska, E., & Balcerska, A. (2011) · Journal of Pediatric Hematology/Oncology · doi:10.1097/mph.0b013e3182172532 · Cited by 11
Üzer, F., Öktem, B., Güven, F. M. K., Kırhan, İ., & Topal, M. (2020) · Medical Gas Research · doi:10.4103/2045-9912.304224 · Cited by 10
Response time of indirectly accessed gas exchange depends on measurement method
Ráfl, J., Kulhanek, F., Kudrna, P., Ort, V., & Roubík, K. (2017) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2017-0070 · Cited by 10
Pop goes the O2: a case of popper-induced methaemoglobinamia
McCabe, A., McCann, B., & Kelly, P. J. (2012) · BMJ Case Reports · doi:10.1136/bcr-2012-007176 · Cited by 10
Intraoperative Diagnosis of Unsuspected Methemoglobinemia Due to Low Pulse Oximetry Values
Tobias, J. D., & Ramachandran, V. (2009) · Journal of Intensive Care Medicine · doi:10.1177/0885066609335732 · Cited by 10
Novel technologies to detect atelectotrauma in the injured lung
Shi, C., Boehme, S., Hartmann, E. K., & Markstaller, K. (2010) · Experimental Lung Research · doi:10.3109/01902148.2010.501402 · Cited by 9
Case 38-2020: A 52-Year-Old Man with Cancer and Acute Hypoxemia
Marinacci, L., Simeone, F. J., Lundquist, A. L., Kuter, D. J., & Mahowald, G. K. (2020) · New England Journal of Medicine · doi:10.1056/nejmcpc2004991 · Cited by 9
Blum, R. H., & Coté, C. J. (2009) · Elsevier eBooks · doi:10.1016/b978-141603134-5.50057-3 · Cited by 9
Batton, R., Villard, S., & Popoff, B. (2024) · La Revue de Médecine Interne · doi:10.1016/j.revmed.2024.05.001 · Cited by 9
Disaster Preparedness and Toxic Exposures in Children
Scalzo, A. J., Lehman-Huskamp, K. L., Sinks, G., & Keenan, W. (2008) · Clinical Pediatric Emergency Medicine · doi:10.1016/j.cpem.2007.12.005 · Cited by 9
Yu, J., Lee, J., Cho, Y., Oh, J., Kang, H., Lim, T. H., & Ko, B. S. (2024) · Journal of Personalized Medicine · doi:10.3390/jpm14020168 · Cited by 8
Umbilical artery base deficit/excess: sailing blindly in a thick fog
Ouellet, P., Racinet, C., & Daboval, T. (2019) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/14767058.2019.1685966 · Cited by 8
Methaemoglobin and COHb in patients with malaria
Hänscheid, T., Gresnigt, T. M., Löhr, S. J. Z., Flamen, A., Zöller, T., Melo‐Cristino, J., & Grobusch, M. P. (2014) · Malaria Journal · doi:10.1186/1475-2875-13-285 · Cited by 7
A severe case of methaemoglobinaemia in a Brazilian hairdresser
de Vere, F., Moores, R., Dhadwal, K., & Karra, E. (2020) · BMJ Case Reports · doi:10.1136/bcr-2019-232735 · Cited by 7
Budidha, K. (2016) · City Research Online (City University London) · Cited by 7
Laboratory kit for pulse oximetry
Havlík, J., & Dvořák, J. (2010) · International Symposium on Applied Sciences in Biomedical and Communication Technologies · doi:10.1109/isabel.2010.5702908 · Cited by 7
Physical and Physiological Problems of Medical Monitoring
Лебединский, К. М., Kovalenko, A. N., Курапеев, И. С., Karelov, A. E., Lenkin, A. I., Subbotin, V. V., Volkov, P. A., & Мартынов, Д. В. (2020) · Technical Physics · doi:10.1134/s1063784220090212 · Cited by 7
Accuracy of non-invasive hemoglobin level measurement in the emergency department
Aseri, Z. A. A., Aldawood, B. A., Altamimi, A. A., Mosleh, H., Qaw, A. S., Albatran, H. I., AlMasri, M. M., AlRihan, T. M., AlAithan, F. B., & AlAssaf, L. S. (2022) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2022.11.012 · Cited by 7
Hazards of the Anesthesia Workstation
Eisenkraft, J. B. (2009) · ASA Refresher Courses in Anesthesiology · doi:10.1097/asa.0b013e3181a7f108 · Cited by 7
Schwere Methämoglobinämie – Diagnostik, Therapie und Pathophysiologie am Beispiel eines Falles
Moos, M., Schröder, R., Lang, M., & Frauchiger, B. (2009) · AINS - Anästhesiologie · Intensivmedizin · Notfallmedizin · Schmerztherapie · doi:10.1055/s-0029-1224778 · Cited by 7
Methemoglobinemia Caused by Portable Dialysis in the Critically Ill
Medarov, B. I., Pahwa, S., Reed, S. S., Blinkhorn, R., Rane, N., & Judson, M. A. (2016) · Critical Care Medicine · doi:10.1097/ccm.0000000000002062 · Cited by 7
McNally, J. S., Jaffey, J. A., Kim, S., Alexander, M. D., Shumway, K. L., Cohn, L. A., Parker, D. L., & Day, R. W. (2019) · Frontiers in Veterinary Science · doi:10.3389/fvets.2019.00416 · Cited by 6
Diagnosis of carbon monoxide exposure in clinical research and practice: A scoping review
Moss, P., Matthews, N. R., McDonald, R., & Jarman, H. (2025) · PLoS ONE · doi:10.1371/journal.pone.0300989 · Cited by 6
Association between severe obstetric hemorrhage and HIV status
Curtis, M. R., Ayadi, A. E., Mkumba, G., Butrick, E. A., Leech, A. A., Geissler, J. D., & Miller, S. (2014) · International Journal of Gynecology & Obstetrics · doi:10.1016/j.ijgo.2013.10.010 · Cited by 6
High-flow nasal cannula in the treatment of acute carbon monoxide poisoning: a pilot study
Gavelli, F., GATTONI, E., Statti, G., Azzolina, D., MAGGI, E., Patrucco, F., Sainaghi, P. P., Avanzi, G. C., Zeppegno, P., & Castello, L. M. (2021) · Minerva Respiratory Medicine · doi:10.23736/s2784-8477.21.01919-2 · Cited by 6
Kaya, S., Bulut, M., Varışlı, B., Kati, Y., & Karaoğlu, U. (2018) · Anatolian Journal of Emergency Medicine · Cited by 6
Lyon, M., Fehlmann, C. A., Augsburger, M. P., Schaller, T., Zimmermann‐Ivol, C. G., Celi, J., Gartner, B., Lorenzon, N., Sarasin, F., & Suppan, L. (2023) · JMIR Formative Research · doi:10.2196/48057 · Cited by 6
Elevated Carboxyhemoglobin in Active Asthma and Allergic Rhinitis as Measured by Pulse CO-Oximetry
Kurlandsky, L. E. (2013) · Pediatric Allergy Immunology and Pulmonology · doi:10.1089/ped.2012.0201 · Cited by 6
Rana, D., Arora, S., Dhawan, I., Dhupia, J. S., & Sethi, S. (2018) · Indian Journal of Medical Specialities · doi:10.1016/j.injms.2018.06.008 · Cited by 5
Ovadia‐Blechman, Z., Gino, O., Dandeker, L., Sheffer, N., Baltaxe, E., & Aharonson, V. (2016) · Journal of Biomedical Science and Engineering · doi:10.4236/jbise.2016.93011 · Cited by 5
Prototype of a multispectral and multiwavelength pulse oximeter based on a BQJ sensor
Chong, A. V., Terosiet, M., Histace, A., & Romain, O. (2017) · IEEE International New Circuits and Systems Conference (NEWCAS) · doi:10.1109/newcas.2017.8010183 · Cited by 5
Noninvasive monitoring with strongly absorbed light
McEwen, M., & Reynolds, K. J. (2014) · Optica Applicata · doi:10.5277/oa140201 · Cited by 5
Sola, A., Altimier, L., Bueno, M. T. M., & Muñoz, C. E. (2023) · Critical Care Nursing Clinics of North America · doi:10.1016/j.cnc.2023.08.004 · Cited by 5
Niemann, M. J., Sørensen, H., Siebenmann, C., Lundby, C., & Secher, N. H. (2017) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2017.1299209 · Cited by 5
Pulse oximetry using a buried quad junction photodetector
Chong, A. V., Terosiet, M., Histace, A., & Romain, O. (2016) · IEEE International Conference on Electronics, Circuits and Systems (ICECS) · doi:10.1109/icecs.2016.7841223 · Cited by 5
Marcatto, J. D. O., Tavares, E. C., & Silva, Y. P. E. (2010) · Revista Brasileira de Terapia Intensiva · doi:10.1590/s0103-507x2010000100012 · Cited by 4
Shank, E. S., Coté, C. J., & Martyn, J. A. J. (2019) · Elsevier eBooks · doi:10.1016/b978-0-323-42974-0.00036-7 · Cited by 4
Kurki, T. S. O., & Eisenkraft, J. B. (2011) · Cambridge University Press eBooks · doi:10.1017/cbo9780511974083.018 · Cited by 4
Markwalter, D. J., Primavera, K. D., Day, R. W., & Lewis, R. S. (2022) · Annals of Biomedical Engineering · doi:10.1007/s10439-022-03049-1 · Cited by 4
Ayati, R., Manwaring, K. C., Allen, S. P., Day, R. W., & Lewis, R. S. (2023) · Annals of Biomedical Engineering · doi:10.1007/s10439-023-03226-w · Cited by 4
Gurley, K. M. (2012) · UKnowledge (University of Kentucky) · Cited by 4
Barker, S. J. (2021) · Elsevier eBooks · doi:10.1016/b978-0-323-67279-5.00011-x · Cited by 4
Self-citationAnesthesia and Prehospital Emergency and Trauma Care
Nägele, P., & Hüpfl, M. (2010) · Elsevier eBooks · doi:10.1016/b978-0-443-06959-8.00073-x · Cited by 4
Taguchi, K., Sumiyoshi, A., Suzuki, Y., Ozawa, Y., Iiyama, M., Gao, S., Sakai, H., Osada, K., Matsumoto, K., & Aoki, I. (2025) · ACS Applied Bio Materials · doi:10.1021/acsabm.4c01451 · Cited by 4
Koyuncu, O., Turhanoğlu, S., Tuzcu, K., Karcıoğlu, M., Davarcı, İ., Akbay, E., Çevik, C., Özer, C., Sessler, D. I., & Turan, A. (2014) · Pediatric Anesthesia · doi:10.1111/pan.12531 · Cited by 4
Bodenstein, M., Boehme, S., Wang, H., Duenges, B., & Markstaller, K. (2014) · Experimental Lung Research · doi:10.3109/01902148.2014.944719 · Cited by 4
Factors that Affect Prognosis and Morbidity in Pediatric Patients with Carbon Monoxide Poisoning
Seçilmiş, Y., & Öztürk, M. A. (2018) · Turkish Journal of Pediatric Emergency and Intensive Care Medicine · doi:10.4274/cayd.71463 · Cited by 4
Duscio, E., Vasques, F., Romitti, F., Cipulli, F., & Gattinoni, L. (2019) · Lessons from the ICU · doi:10.1007/978-3-319-69269-2_9 · Cited by 4
Chubb, D., Whitaker, I. S., Rozen, W. M., & Ashton, M. W. (2011) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0b013e3182365db4 · Cited by 4
Bessereau, J., Heireche, F., Brémond, V., Boutin, A., Petit, S., Tsapis, M., Boiron, L., Puget, A., Garry, P., Coulange, M., et al. (2018) · Toxicology and Industrial Health · doi:10.1177/0748233718756703 · Cited by 4
Litman, R. S., Cohen, D. E., Sclabassi, R. J., Callahan, P. M., Cladis, F. P., & Motoyama, E. K. (2011) · Elsevier eBooks · doi:10.1016/b978-0-323-06612-9.00011-0 · Cited by 3
Wang, Y., Pu, L., Wu, D., Lin, W.-H., Wong, K. K. L., & Zhang, H. (2015) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519415500153 · Cited by 3
Feasibility study of a wearable carbon monoxide warning system for construction workers
Forsyth, J. B., Martin, T. L., Young-Corbett, D. E., & Dorsa, E. (2011) · IEEE International Conference on Pervasive Computing and Communications · doi:10.1109/percom.2011.5767592 · Cited by 3
Granelli, A. D. (2009) · Cited by 3
Gnoevykh, V. V., Shorokhova, Y. A., Smirnova, A. Y., & Chernova, N. G. (2022) · Medical alphabet · doi:10.33667/2078-5631-2022-9-46-49 · Cited by 3
Carbon monoxide intoxication: not only a silent killer
Statti, G., Daverio, M., Shi, R., & Balbo, P. E. (2021) · Minerva Pneumologica · doi:10.23736/s0026-4954.20.01904-5 · Cited by 3
YORULMAZ, İ. S., Özlü, O., Demiraran, Y., Sezen, G., & Boran, E. (2015) · International Journal of Clinical Medicine · doi:10.4236/ijcm.2015.612125 · Cited by 3
Cambiaso‐Daniel, J., Voigt, C. D., Rivas, E., Hundeshagen, G., Lopez, O. N., Kamolz, L., Sljivich, M., Sousse, L. E., Herndon, D. N., Suman-Vejas, O. E., et al. (2017) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0000000000001287 · Cited by 3
Arterial Blood Gas Measurements
Gross, R. L., & Peruzzi, W. T. (2008) · Elsevier eBooks · doi:10.1016/b978-032304841-5.50016-9 · Cited by 3
Noninvasive Monitoring in Children
Rampersad, S. E., Schenkman, K. A., & Martin, L. D. (2011) · Elsevier eBooks · doi:10.1016/b978-0-323-07307-3.10043-6 · Cited by 3
Intoxicación por monóxido de carbono
Sivanandamoorthy, S., Meng, P., Heming, N., & Annane, D. (2018) · EMC - Anestesia-Reanimación · doi:10.1016/s1280-4703(18)91272-7 · Cited by 3
Simultaneous Measurement of Oxygen and Carbon Monoxide Saturation using Pulse Oximeters
Vasudevan, S. (2011) · Digital WPI · Cited by 3
Treatment and evaluation of specific toxins
Beuhler, M. C. (2021) · Wiley eBooks · doi:10.1002/9781119756279.ch47 · Cited by 3
Erdmann, M., Schöppenthau, H., & Büttner, J. (2009) · Der Anaesthesist · doi:10.1007/s00101-009-1518-z · Cited by 3
Velyhotskyi, D. (2025) · Studies in systems, decision and control · doi:10.1007/978-3-031-82035-9_5 · Cited by 3
Methemoglobinemia in Patients Undergoing Esophagogastroduodenoscopy: A Randomized Controlled Trial
Hall, N., Jones, F. J., Ainsworth, C., & Fincher, R. K. (2013) · Military Medicine · doi:10.7205/milmed-d-13-00035 · Cited by 3
Mahoney, A. M., Stimpson, C. L., Scott, K. L., & Hampson, N. B. (2007) · Respiratory Care · doi:10.4187/respcare.07521741 · Cited by 3
Where There Is Smoke… Inhalation Injuries, Carbon Monoxide, and Cyanide Poisoning
Sahjian, M., & Frakes, M. A. (2008) · Advanced Emergency Nursing Journal · doi:10.1097/01.tme.0000319928.43215.29 · Cited by 3
Improved Single-LED Pulse Oximeter Design Based on Multi-Wavelength Analysis
Beguni, C., Căilean, A.-M., Avătămăniței, S.-A., & Dimian, M. (2022) · International Conference on Development and Application Systems (DAS) · doi:10.1109/das54948.2022.9786087 · Cited by 3
Healthy blue man: congenital methemoglobinemia
Rao, B. V. N., Sinha, S., Modi, S., & Sunita, S. (2017) · International Journal of Research in Medical Sciences · doi:10.18203/2320-6012.ijrms20174610 · Cited by 2
Kosaka, M., Yoshida, A., & Ohe, K. (2016) · Journal of the Japanese Society of Intensive Care Medicine · doi:10.3918/jsicm.23.625 · Cited by 2
Pediatric Anesthesia Monitoring
Cohen, D. E., Diaz, L. K., & Balzer, J. R. (2017) · Elsevier eBooks · doi:10.1016/b978-0-323-34125-7.00017-6 · Cited by 2
OTHER CLINICALLY IMPORTANT DISORDERS OF HEMOGLOBIN
Steinberg, M. H. (2009) · Cambridge University Press eBooks · doi:10.1017/cbo9780511596582.032 · Cited by 2
Towards Spectral Pulse Oximetry Independent of Motion Artifacts
Chong, A. V., Terosiet, M., Histace, A., & Romain, O. (2018) · Euromicro Conference on Digital System Design (DSD) · doi:10.1109/dsd.2018.00085 · Cited by 2
Lee, T. J., & Borgman, M. A. (2022) · Springer eBooks · doi:10.1007/978-3-031-06959-8_31 · Cited by 2
Kim, S.-E., McNally, J. S., Alexander, M. D., Zabriskie, M. S., Parker, D. L., & Day, R. W. (2023) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2023.06.018 · Cited by 2
Classical Respiratory Monitoring
Cheifetz, I. M., Salyer, J. W., Schmalisch, G., & Tobias, J. D. (2014) · Springer eBooks · doi:10.1007/978-3-642-01219-8_12 · Cited by 2
Prognostic value of carboxyhemoglobin in pediatric intensive care unit
Alakaya, M., & Arslanköylü, A. E. (2022) · Pakistan Journal of Medical Sciences · doi:10.12669/pjms.38.7.5753 · Cited by 2
Instantaneous carboxyhemoglobin level change due to smoking and analysis of baseline SpCO in smokers
Kocaoğlu, S., & Alatlı, T. (2025) · BMC Pharmacology and Toxicology · doi:10.1186/s40360-025-00979-z · Cited by 2
Mosesso, V. N., & Jameson, A. M. (2015) · Wiley eBooks · doi:10.1002/9781118990810.ch6 · Cited by 2
Anand, A., & Satyanarayana, T. (2012) · Cited by 2
Transcutaneous CO-oximetry differentiates asthma exacerbation and convalescence in children
Kantor, D. B., Petty, C. R., Phipatanakul, W., & Gaffin, J. M. (2018) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2018.02.048 · Cited by 2
Gisbrecht, A. I., Мамилов, С. А., & Esman, S. S. (2019) · AIP conference proceedings · doi:10.1063/1.5091385 · Cited by 2
Mosesso, V. N., & Jameson, A. M. (2021) · Wiley eBooks · doi:10.1002/9781119756279.ch6 · Cited by 2
New Sensors Should Improve Masimo SpMet Error Found by Feiner et al.
Barker, S. J. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181e2936c · Cited by 2
Self-citationNon-Invasive Screening for Carbon Monoxide Toxicity in the Emergency Department is Valuable
Suner, S., Partridge, R. A., Sucov, A., Chee, K., Valente, J. H., & Jay, G. D. (2007) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2006.10.034 · Cited by 2
Paul-Girot, S. (2015) · HAL · Cited by 2
Kiani, J., & Goldstein, M. (2021) · Neonatology Today · doi:10.51362/neonatology.today/20214164143145 · Cited by 1
Peripheral Oxygen Saturation Measurement: Could the Wrist be an Alternative Site for a Finger?
Devaki, V., Lakshmanan, M. K., & Jayanthi, T. (2023) · IEEE World Conference on Applied Intelligence and Computing (AIC) · doi:10.1109/aic57670.2023.10263821 · Cited by 1
Kobayashi, N., & Yamamori, S. (2017) · Springer eBooks · doi:10.1007/978-3-319-69362-0_11 · Cited by 1
Wearable Pulse Oximetry in Construction Environments
Forsyth, J. B. (2010) · VTechWorks (Virginia Tech) · Cited by 1
Monitoring the Airway and Pulmonary Function
Cohen, N. H., & Schwartz, D. E. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4377-2764-7.00049-x · Cited by 1
Anästhesie bei Patienten mit Anämien, Polyzythämien und Methämoglobinämie
Waschke, K. F. (2019) · Springer Reference Medizin · doi:10.1007/978-3-662-54507-2_108 · Cited by 1
Metadata
- Authors
- Barker, S. J., Curry, J., Redford, D., & Morgan, S.
- Venue
- Anesthesiology
- Published
- 2006-11-01
- Volume
- 105
- Issue
- 5
- Pages
- 892-897
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2123754678
- Cited by
- 238
- References
- 16
- FWCI
- 9.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.