Measurement of Carboxyhemoglobin and Methemoglobin by Pulse Oximetry: A Human Volunteer Study
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Background: A new eight-wavelength pulse oximeter is designed to measure methemoglobin and carboxyhemoglobin, in addition to the usual measurements of hemoglobin oxygen saturation and pulse rate. This study examines this device's ability to measure dyshemoglobins in human volunteers in whom controlled levels of methemoglobin and carboxyhemoglobin are induced. Methods: Ten volunteers breathed 500 ppm carbon monoxide until their carboxyhemoglobin levels reached 15%, and 10 different volunteers received intravenous sodium nitrite, 300 mg, to induce methemoglobin. All were instrumented with arterial cannulas and six Masimo Rad-57 (Masimo Inc., Irvine, CA) pulse oximeter sensors. Arterial blood was analyzed by three laboratory CO-oximeters, and the resulting carboxyhemoglobin and methemoglobin measurements were compared with the corresponding pulse oximeter readings. Results: The Rad-57 measured carboxyhemoglobin with an uncertainty of +/-2% within the range of 0-15%, and it measured methemoglobin with an uncertainty of 0.5% within the range of 0-12%. Conclusion: The Masimo Rad-57 is the first commercially available pulse oximeter that can measure methemoglobin and carboxyhemoglobin, and it therefore represents an expansion of our oxygenation monitoring capability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Conventional pulse oximetry cannot distinguish between COHb and oxyHb, and, as such, can miss signi fi cant COHb levels and profound hypoxia (44).”
From Carbon monoxide poisoning: pathogenesis, management, and future directions of therapy (2017) · cites this paper as [44]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300 · cited 2×
“Bias (mean error) and precision (SD of error) were calculated as recommended by Altman and Bland.7 Linear regression was used to calculate the slope and intercept of the best fit straight line relation between the two methods.”
MethodEffects of Methemoglobinemia on Pulse Oximetry and Mixed Venous Oximetry
Barker, S. J., Tremper, K. K., & Hyatt, J. (1989) · Anesthesiology · doi:10.1097/00000542-198901000-00021 · Cited by 382 · cited 2×
“to drive the SpO2 readings toward 85%, no matter what the actual oxygen saturation.(3) In this animal study, metUS Department of Labor report on Sago Mine disaster.”
BackgroundMethodSelf-citationThe Effect of Carbon Monoxide Inhalation on Pulse Oximetry and Transcutaneous Po 2
Barker, S. J., & Tremper, K. K. (1987) · Anesthesiology · doi:10.1097/00000542-198705000-00014 · Cited by 281
Self-citationEffects of Intravenously Administered Dyes on Pulse Oximetry Readings
SCHELLER, M. S., UNGER, R. J., & KELNER, M. J. (1986) · Anesthesiology · doi:10.1097/00000542-198611000-00023 · Cited by 194
History of blood gas analysis. VII. Pulse oximetry
Severinghaus, J. W., & Honda, Y. (1987) · Journal of Clinical Monitoring · doi:10.1007/bf00858362 · Cited by 179 · cited 1×
“Since its invention by Aoyagi in 1974, the pulse oximeter has become the most common monitor of patient oxygenation.(8) However, all pulse oximeters in clinical use to date share a serious limitation.”
BackgroundThe antidotal action of sodium nitrite and sodium thiosulfate against cyanide poisoning
Baskin, S. I., Horowitz, A. M., & Nealley, E. W. (1992) · The Journal of Clinical Pharmacology · doi:10.1002/j.1552-4604.1992.tb03849.x · Cited by 165
Pulse Oximetry in Severe Carbon Monoxide Poisoning
Hampson, N. B. (1998) · CHEST Journal · doi:10.1378/chest.114.4.1036 · Cited by 145 · cited 1×
“2,3 These errors have been confirmed in clinical case reports.(4,5) No pre-”
BackgroundPulse Oximetry in Methemoglobinemia
Watcha, M. F., Connor, M. T., & Hing, A. V. (1989) · Archives of Pediatrics and Adolescent Medicine · doi:10.1001/archpedi.1989.02150190095030 · Cited by 69 · cited 1×
“2,3 These errors have been confirmed in clinical case reports.(4,5) No pre-”
BackgroundSevere Carbon Monoxide Poisoning during Desflurane Anesthesia
Berry, P. D., Sessler, D. I., & Larson, M. D. (1999) · Anesthesiology · doi:10.1097/00000542-199902000-00036 · Cited by 65 · cited 1×
“Louis, MO) has also caused serious toxicity.(11)”
Benzocaine-Induced Methemoglobinemia in an Adult: Accuracy of Pulse Oximetry with Methemoglobinemia
Anderson, S. T., Hajduczek, J., & Barker, S. J. (1988) · Anesthesia & Analgesia · doi:10.1213/00000539-198811000-00015 · Cited by 64
Self-citation
Cited by
Items 201–275 of 275
Barker, S. J. (2013) · Elsevier eBooks · doi:10.1016/b978-0-323-11237-6.00011-x · Cited by 1
Self-citationThe Use of Pulse Oximetry in Pediatric Emergency Department: Review
Güleryüz, O. D., & Eyüboğlu, T. Ş. (2016) · Turkiye Klinikleri Journal of Pediatrics · doi:10.5336/pediatr.2016-50615 · Cited by 1
New indications for peripheral pulse wave
Harju, J. (2018) · Tampere University Institutional Repository (Tampere University) · Cited by 1
Intossicazione da monossido di carbonio
Sivanandamoorthy, S., Meng, P., Heming, N., & Annane, D. (2018) · EMC - Anestesia-Rianimazione · doi:10.1016/s1283-0771(18)91366-6 · Cited by 1
Intoxication au monoxyde de carbone
Sivanandamoorthy, S., Meng, P., Heming, N., & Annane, D. (2018) · Cited by 1
Atmospheric Carbon-Monoxide in Some Local Government Areas in Ondo State, Nigeria
Uche, J. I., Ediagbonya, T. F., Akpojivi, O. V., Oziegbe, F. E., & John, J. (2025) · Journal of applied science and environmental management · doi:10.4314/jasem.v29i9.17 · Cited by 1
Carbon monoxide poisoning: assessment, treatment, and outcomes
Zein, A. R., Almalki, E. B., Almasabi, H. A., Alzahrani, H. T., Alabdali, R. H., Alsalamah, Z. K., Alhaeti, H. R., Alsuroji, A. H., Bugis, A. H., Sadiq, F. A. A., et al. (2021) · International Journal of Community Medicine and Public Health · doi:10.18203/2394-6040.ijcmph20214297 · Cited by 1
Wagner, F., Henze, C., Baumann, H., & Biscoping, J. (2013) · Notfall + Rettungsmedizin · doi:10.1007/s10049-012-1665-7 · Cited by 1
Treatment and evaluation of specific toxins
Beuhler, M. C. (2015) · Wiley eBooks · doi:10.1002/9781118990810.ch47 · Cited by 1
Noninvasive hemoglobin measurement in pregnancy
Bourke, M., Cooley, S. M., McMorrow, R., & McAuliffe, F. M. (2014) · International Journal of Gynecology & Obstetrics · doi:10.1016/j.ijgo.2013.10.014 · Cited by 1
Noninvasive Measurement of Carboxyhemoglobin in Cystic Fibrosis Patients by Pulse CO-Oximeter
Kurlandsky, L. E., Anbar, R. D., & Soultan, Z. N. (2012) · Pediatric Allergy Immunology and Pulmonology · doi:10.1089/ped.2011.0108 · Cited by 1
Post-frenotomy Methemoglobinemia Associated with Mepivacaine Use in a 3 Day Old
Avarello, J. T. (2013) · Emergency Medicine Open Access · doi:10.4172/2165-7548.1000131 · Cited by 1
Pulse Oximetry From Past to Present
King, T. (2011) · Journal of Clinical Engineering · doi:10.1097/jce.0b013e318223cbad · Cited by 1
Methemoglobinemia in a 14-year-old girl with new-onset dyspnea
Wallace, M., Tenbarge, C., Harlow, S., Kasting, N., & Gooden, J. (2019) · JAAPA · doi:10.1097/01.jaa.0000586320.66253.a9 · Cited by 1
Methemoglobinemia and arterial blood gas
Tin, S. S., & Wiwanitkit, V. (2015) · Indian Heart Journal · doi:10.1016/j.ihj.2015.02.001 · Cited by 1
Abdelhamid, B. M., Elsonbaty, M., & Elsonbaty, A. (2017) · Journal of Anesthesia & Clinical Research · doi:10.4172/2155-6148.1000712
van Wonderen, S. F., Aguirre, A., Benni, P., van den Dool, R. E. C., Pingarrón, J. P. M., Solares, G. J., Hatib, F., Veelo, D. P., Vlaar, A. P. J., & Jian, Z. (2025) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000007618
Shank, E. S., Sheridan, R. L., Coté, C. J., & Martyn, J. A. J. (2009) · Elsevier eBooks · doi:10.1016/b978-141603134-5.50038-x
Arastoo, M., Mazanetz, M. P., Miller, S., Shiells, H., Hull, C. E., Robinson, K. A., Storey, J. M. D., Harrington, C. R., & Wischik, C. M. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms241813747
Anästhesie bei Erkrankungen des Bluts
Waschke, K. F. (2012) · Springer eBooks · doi:10.1007/978-3-642-21125-6_69
(2007) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0b013e3282f355c3
Current research on cigarette toxicity: critical appraisal in view of clinical laboratory
Gyawali, P., & Oguoma, V. M. (2016) · International Journal of Research in Medical Sciences · doi:10.18203/2320-6012.ijrms20161725
Anästhesie bei Patienten mit Anämien, Polyzythämien und Methämoglobinämie
Waschke, K. F. (2016) · Springer eBooks · doi:10.1007/978-3-662-45539-5_108-1
Non-invasive photoplethysmography and contact pressure optical fibre sensor
Liu, C. (2020) · Nottingham ePrints (University of Nottingham)
O’Malley, G. F. (2007) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2006.11.028
Pulse Oximetry—A Perioperative Perspective
Moon, K., Daino, N., Gomez, P., Arias, J., Toubasi, A. Y. M., & Pulijal, S. V. (2026) · Diagnostics · doi:10.3390/diagnostics16121812
Godement, M., Prigent, A., Mereiles, S., Nahon, M., Prunet, B., Vivien, B., & Jouffroy, R. (2023) · EMC - Urgenze · doi:10.1016/s1286-9341(22)47493-x
Köksal, B. G., Küçükosman, G., Pişkin, Ö., Baytar, Ç., Bollucuoğlu, K., Okyay, R. D., & Ayoğlu, H. (2022) · Saudi Medical Journal · doi:10.15537/smj.2022.43.8.20220424
“The pulse oximetry gap”: definition, reasons, diagnostics and clinical significance
Gnoevykh, V. V., Smirnova, A. Y., Shorokhova, Y. A., Chernova, N. G., Крестьянинов, М. В., Peskov, A. B., & Разин, В. А. (2023) · Medical alphabet · doi:10.33667/2078-5631-2023-32-20-26
Machine learning algorithm development of SPO2 sensor for improved robustness in wearables
Veiga, P. D. B. (2022) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT)
Santander, E. (2021) · uO Research (University of Ottawa) · doi:10.20381/ruor-26042
Wireless, Implantable Oximeter for the Remote Monitoring of Physiological Biomarkers
Usatinsky, A. (2024) · TSpace (University of Toronto)
Wall, J. L., Wong, J. B., Kinderknecht, K. J., Leslie, C., Farrior, K., & Gabbay, D. S. (2016)
Methaemoglobinaemia: a case of mistaken identity
Washington, S. J., Meadows, D. P., & McCluskey, A. (2007) · British Journal of Hospital Medicine · doi:10.12968/hmed.2007.68.9.27176
Reliability of non-invasive measurement of tissue effects of lung ventilation
Kulhanek, F., & Filip, K. (2016) · Cvut DSpace (Czech Technical University)
Özen, E. (2011) · Trakya University's Institutional Open Access System (Trakya University)
Lyon, M. (2024) · Archive ouverte UNIGE (University of Geneva) · doi:10.13097/archive-ouverte/unige:178230
Multi and Hyperspectral Imaging of Early Detection of Disease
Taylor-Williams, M. (2023) · Apollo (University of Cambridge) · doi:10.17863/cam.108052
Accuracy of pulse oximetry during neonatal resuscitation
Hassan, M. A. (2014) · OPen Access Repositorium der Universität Ulm (OPARU) (Ulm University) · doi:10.18725/oparu-4284
Rocq, N. (2010) · Publications Et Travaux Academiques de Lorraine (Universite de Lorraine)
Intossicazione da monossido di carbonio
Sivanandamoorthy, S., Meng, P., Heming, N., & Annane, D. (2022) · EMC - Urgenze · doi:10.1016/s1286-9341(22)46437-4
Lee, H. Y., Kim, D. K., & Lee, Y. (2026) · Scientific Reports · doi:10.1038/s41598-026-51424-y
Acute respiratory injuries caused by housefires
Lintula, M. (2025) · UEF eRepo (University of Eastern Finland)
Jännetyinen, S., & Nappa, N. (2018) · Theseus (Ammattikorkeakoulujen)
Klug, N. E. (2015) · mediaTUM (Technical University of Munich)
Неінвазивний моніторинг стану людини при інтоксикації монооксидом вуглецю
Velyhotskyi, D. (2023) · Електронний архів наукових та освітніх матеріалів КПІ ім. Ігоря Сікорського (КПІ ім. Ігоря Сікорського)
Evaluation d'un matériel de dépistage de l'intoxication au monoxyde de carbone en médecine générale
Libert, A. (2012) · Publications Et Travaux Academiques de Lorraine (Universite de Lorraine)
Taşkın, Ö. (2023) · Akademisyen Kitabevi eBooks · doi:10.37609/akya.2461.c14498
Czaplik, M., Brokmann, J. C., & Rossaint, R. (2010) · AINS - Anästhesiologie · Intensivmedizin · Notfallmedizin · Schmerztherapie · doi:10.1055/s-0029-1243373
Bewusstseinsstörung bei einer jungen Frau
Czaplik, M., Brokmann, J. C., & Rossaint, R. (2010) · Notarzt · doi:10.1055/s-0029-1223516
New Pulse Oximeter Measures Carboxyhemoglobin and Methemoglobin
Walls, R. M., Frcpc, Facep, & Faaem (2006) · Journal watch · doi:10.1056/em200612010000003
Meidert, A. S., Lang, A., Hennig, G., Bernasconi, P., Peraud, A., Briegel, J., & Hüttl, T. K. (2016) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-016-9865-1
Pulse Oximetry in Acute Respiratory Failure: What Should Be Expected?
Haynes, J. M., & Ruppel, G. L. (2016) · Respiratory Care · doi:10.4187/respcare.04965
真茅, 孝. (2014) · JAPANES JOURNAL OF MEDICAL INSTRUMENTATION · doi:10.4286/jjmi.84.469
Cortés-Samacá, C. A., Cogollo, C. A. P., Gamba, A. M. C., & Navia, D. M. S. (2018) · Journal of Science Humanities and Arts - JOSHA · doi:10.17160/josha.5.2.386
Gökhan, A. S. A. N., İşbir, A. C., Avcı, O., Kol, İ. Ö., Kaygusuz, K., & Gürsoy, S. (2018) · Turkiye Klinikleri Journal of Anesthesiology Reanimation · doi:10.5336/anesthe.2018-61045
Физические и физиологические проблемы медицинского мониторинга
Лебединский, К. М., Коваленко, А. Н., Курапеев, И. С., Karelov, A. E., Lenkin, A. I., В., С. В., Волков, П. А., & Мартынов, Д. В. (2020) · Журнал технической физики · doi:10.21883/jtf.2020.09.49670.69-20
Taraz, M., Farnaghi, F., Hassanian‐Moghaddam, H., & Gachkar, L. (2020) · Researcher Bulletin of Medical Sciences
Anästhesie bei Erkrankungen des Blutes
Waschke, K. F. (2008) · Springer eBooks · doi:10.1007/978-3-540-76302-4_67
Secret Carbon Monoxide Intoxication Assessments of the Patients Who Presented to Emergency
Derya, S., Gürbüz, Ş., Oğuztürk, H., Yücel, N., Turtay, M. G., Ekmekyapar, M., Uyanik, Ö., & GÖKÇE, H. (2022) · Medical Records · doi:10.37990/medr.1103558
Carbon monoxide intoxication: A report of two cases
Hajdinjak, E., Markota, A., Košir, A. S., & Kirbiš, S. (2021) · Acta Medico-Biotechnica · doi:10.18690/actabiomed.99
FUNCIONAMENTO E APLICABILIDADE DO FOTODIODO NA ENGENHARIA BIOMÉDICA
der Strasse, W. A., Pichorim, S. F., & Nohama, P. (2020) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.5281/zenodo.8084349
Metahemoglobinemia em paciente com Lúpus Eritematoso Sistêmico, induzida por hanseníase
Santos, R. R. D. (2024) · Brazilian Journal of Health Review · doi:10.34119/bjhrv7n1-112
Perioperative Management of Undiagnosed Methaemoglobinaemia
Sreevani, M., & Rajapriya, R. (2022) · International Journal of Science and Research (IJSR) · doi:10.21275/sr221109142733
Hasan, A. (2025) · Springer eBooks · doi:10.1007/978-981-96-7810-5_14
Utilizzo del pulsossimetro in subacquei in immersione per rilevare l'ipossia. Uno studio pilota.
DI PUMPO, F. (2018) · Electronic Theses and Dissertations Repository (University of Pisa)
Giden, R. (2022) · Akademisyen Kitabevi eBooks · doi:10.37609/akya.1308.c16307
Jöhr, M. (2022) · Elsevier eBooks · doi:10.1016/b978-3-437-22922-0.00005-6
Sears, C. C. (2026) · doi:10.67999/b0001.c29
Niño, M. C., Romero-Fragozo, A., Solano-Salazar, A., & Mejía, J. A. (2026) · Frontiers in Anesthesiology · doi:10.3389/fanes.2026.2016882
Metadata
- Authors
- Barker, S. J., Curry, J., Redford, D., & Morgan, S.
- Venue
- Anesthesiology
- Published
- 2006-11-01
- Volume
- 105
- Issue
- 5
- Pages
- 892-897
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2123754678
- Cited by
- 238
- References
- 16
- FWCI
- 9.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.