Measurement of Carboxyhemoglobin and Methemoglobin by Pulse Oximetry: A Human Volunteer Study
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Background: A new eight-wavelength pulse oximeter is designed to measure methemoglobin and carboxyhemoglobin, in addition to the usual measurements of hemoglobin oxygen saturation and pulse rate. This study examines this device's ability to measure dyshemoglobins in human volunteers in whom controlled levels of methemoglobin and carboxyhemoglobin are induced. Methods: Ten volunteers breathed 500 ppm carbon monoxide until their carboxyhemoglobin levels reached 15%, and 10 different volunteers received intravenous sodium nitrite, 300 mg, to induce methemoglobin. All were instrumented with arterial cannulas and six Masimo Rad-57 (Masimo Inc., Irvine, CA) pulse oximeter sensors. Arterial blood was analyzed by three laboratory CO-oximeters, and the resulting carboxyhemoglobin and methemoglobin measurements were compared with the corresponding pulse oximeter readings. Results: The Rad-57 measured carboxyhemoglobin with an uncertainty of +/-2% within the range of 0-15%, and it measured methemoglobin with an uncertainty of 0.5% within the range of 0-12%. Conclusion: The Masimo Rad-57 is the first commercially available pulse oximeter that can measure methemoglobin and carboxyhemoglobin, and it therefore represents an expansion of our oxygenation monitoring capability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Conventional pulse oximetry cannot distinguish between COHb and oxyHb, and, as such, can miss signi fi cant COHb levels and profound hypoxia (44).”
From Carbon monoxide poisoning: pathogenesis, management, and future directions of therapy (2017) · cites this paper as [44]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300 · cited 2×
“Bias (mean error) and precision (SD of error) were calculated as recommended by Altman and Bland.7 Linear regression was used to calculate the slope and intercept of the best fit straight line relation between the two methods.”
MethodEffects of Methemoglobinemia on Pulse Oximetry and Mixed Venous Oximetry
Barker, S. J., Tremper, K. K., & Hyatt, J. (1989) · Anesthesiology · doi:10.1097/00000542-198901000-00021 · Cited by 382 · cited 2×
“to drive the SpO2 readings toward 85%, no matter what the actual oxygen saturation.(3) In this animal study, metUS Department of Labor report on Sago Mine disaster.”
BackgroundMethodSelf-citationThe Effect of Carbon Monoxide Inhalation on Pulse Oximetry and Transcutaneous Po 2
Barker, S. J., & Tremper, K. K. (1987) · Anesthesiology · doi:10.1097/00000542-198705000-00014 · Cited by 281
Self-citationEffects of Intravenously Administered Dyes on Pulse Oximetry Readings
SCHELLER, M. S., UNGER, R. J., & KELNER, M. J. (1986) · Anesthesiology · doi:10.1097/00000542-198611000-00023 · Cited by 194
History of blood gas analysis. VII. Pulse oximetry
Severinghaus, J. W., & Honda, Y. (1987) · Journal of Clinical Monitoring · doi:10.1007/bf00858362 · Cited by 179 · cited 1×
“Since its invention by Aoyagi in 1974, the pulse oximeter has become the most common monitor of patient oxygenation.(8) However, all pulse oximeters in clinical use to date share a serious limitation.”
BackgroundThe antidotal action of sodium nitrite and sodium thiosulfate against cyanide poisoning
Baskin, S. I., Horowitz, A. M., & Nealley, E. W. (1992) · The Journal of Clinical Pharmacology · doi:10.1002/j.1552-4604.1992.tb03849.x · Cited by 165
Pulse Oximetry in Severe Carbon Monoxide Poisoning
Hampson, N. B. (1998) · CHEST Journal · doi:10.1378/chest.114.4.1036 · Cited by 145 · cited 1×
“2,3 These errors have been confirmed in clinical case reports.(4,5) No pre-”
BackgroundPulse Oximetry in Methemoglobinemia
Watcha, M. F., Connor, M. T., & Hing, A. V. (1989) · Archives of Pediatrics and Adolescent Medicine · doi:10.1001/archpedi.1989.02150190095030 · Cited by 69 · cited 1×
“2,3 These errors have been confirmed in clinical case reports.(4,5) No pre-”
BackgroundSevere Carbon Monoxide Poisoning during Desflurane Anesthesia
Berry, P. D., Sessler, D. I., & Larson, M. D. (1999) · Anesthesiology · doi:10.1097/00000542-199902000-00036 · Cited by 65 · cited 1×
“Louis, MO) has also caused serious toxicity.(11)”
Benzocaine-Induced Methemoglobinemia in an Adult: Accuracy of Pulse Oximetry with Methemoglobinemia
Anderson, S. T., Hajduczek, J., & Barker, S. J. (1988) · Anesthesia & Analgesia · doi:10.1213/00000539-198811000-00015 · Cited by 64
Self-citation
Cited by
Carbon monoxide poisoning: pathogenesis, management, and future directions of therapy
Rose, J. J., Wang, L., Xu, Q., McTiernan, C. F., Shiva, S., Tejero, J., & Gladwin, M. T. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201606-1275ci · Cited by 965
Jubran, A. (2015) · Critical Care · doi:10.1186/s13054-015-0984-8 · Cited by 491
Pulse oximetry: fundamentals and technology update
Nitzan, M., Romem, A., & Koppel, R. (2014) · Medical Devices: Evidence and Research · doi:10.2147/mder.s47319 · Cited by 438
“Some studies showed accurate measurement of COHb and MetHb, 22,40–42 while others 43,44 claim that pulse co-oximetry cannot replace standard blood COHb measurement, though it could be used as a first-line screening test.”
Methemoglobinemia Related to Local Anesthetics: A Summary of 242 Episodes
Guay, J. M. Y. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318187c4b1 · Cited by 357
Practice recommendations in the diagnosis, management, and prevention of carbon monoxide poisoning
Hampson, N. B., Piantadosi, C. A., Thom, S. R., & Weaver, L. K. (2012) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201207-1284ci · Cited by 331
Pulse Oximetry in Pediatric Practice
Fouzas, S., Priftis, K. N., & Anthracopoulos, M. B. (2011) · Pediatrics · doi:10.1542/peds.2011-0271 · Cited by 219
Metemoglobinemia: do diagnóstico ao tratamento
do Nascimento, T. S., Pereira, R. O. L., de Mello, H. L. D., & da Costa, J. C. B. (2008) · Brazilian Journal of Anesthesiology · doi:10.1590/s0034-70942008000600011 · Cited by 211
The Diagnosis and Treatment of Carbon Monoxide Poisoning
Eichhorn, L., Thudium, M. O., & Jüttner, B. (2018) · Deutsches Ärzteblatt international · doi:10.3238/arztebl.2018.0863 · Cited by 172
Quandt, B. M., Scherer, L. J., Boesel, L. F., Wolf, M., Bona, G., & Rossi, R. M. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400463 · Cited by 148
Chenoweth, J., Albertson, T. E., & Greer, M. R. (2021) · Critical Care Clinics · doi:10.1016/j.ccc.2021.03.010 · Cited by 122
A review of the effect of skin pigmentation on pulse oximeter accuracy
Al-Halawani, R., Charlton, P. H., Qassem, M., & Kyriacou, P. A. (2023) · Physiological Measurement · doi:10.1088/1361-6579/acd51a · Cited by 119
Performance Evaluation of a Noninvasive Hemoglobin Monitoring Device
Gayat, É., Bodin, A., Sportiello, C., Boisson, M., Dreyfus, J., Mathieu, E., & Fischler, M. (2011) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2010.11.032 · Cited by 119
Suner, S., Partridge, R. A., Sucov, A., Valente, J. H., Chee, K., Hughes, A. M., & Jay, G. D. (2008) · Journal of Emergency Medicine · doi:10.1016/j.jemermed.2007.12.004 · Cited by 107
The measurement of dyshemoglobins and total hemoglobin by pulse oximetry
Barker, S. J., & Badal, J. J. (2008) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0b013e328316bb6f · Cited by 106
Self-citationCarbon monoxide poisoning in the 21st century
Chiew, A. L., & Buckley, N. A. (2014) · Critical Care · doi:10.1186/cc13846 · Cited by 105
Touger, M., Birnbaum, A. J., Wang, J., Chou, K., Pearson, D., & Bijur, P. E. (2010) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2010.03.041 · Cited by 100
A Multi-Sensor and Parallel Processing SoC for Miniaturized Medical Instrumentation
Schonle, P., Glaser, F., Burger, T., Rovere, G., Benini, L., & Huang, Q. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2018.2815653 · Cited by 98
Carbon monoxide and cyanide toxicity: etiology, pathophysiology and treatment in inhalation injury
Huzar, T. F., George, T. C., & Cross, J. M. (2013) · Expert Review of Respiratory Medicine · doi:10.1586/ers.13.9 · Cited by 96
von Roth, D., Herkner, H., Schreiber, W., Hubmann, N., Gamper, G., Laggner, A. N., & Havel, C. (2011) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2010.12.024 · Cited by 87
Scott, M. G., LeGrys, V. A., & Hood, J. L. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4160-6164-9.00028-7 · Cited by 86
Noninvasive hemoglobin sensing and imaging: optical tools for disease diagnosis
Taylor-Williams, M., Spicer, G. L. C., Bale, G. M., & Bohndiek, S. E. (2022) · Journal of Biomedical Optics · doi:10.1117/1.jbo.27.8.080901 · Cited by 74
Cardiovascular Abnormalities in Carbon Monoxide Poisoning
Garg, J., Krishnamoorthy, P. M., Palaniswamy, C., Khera, S., Ahmad, H. A., Jain, D., Aronow, W. S., & Frishman, W. H. (2014) · American Journal of Therapeutics · doi:10.1097/mjt.0000000000000016 · Cited by 73
Valdez-Lowe, C., Ghareeb, S. A., & Artinian, N. T. (2009) · AJN American Journal of Nursing · doi:10.1097/01.naj.0000352474.55746.81 · Cited by 72
A new tool for the early diagnosis of carbon monoxide intoxication
Piatkowski, A. A., Ulrich, D. J. O., Grieb, G., & Pallua, N. (2009) · Inhalation Toxicology · doi:10.3109/08958370902839754 · Cited by 71
Accuracy of Methemoglobin Detection by Pulse CO-Oximetry During Hypoxia
Feiner, J., Bickler, P. E., & Mannheimer, P. D. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181c91bb6 · Cited by 63
Clinical outcomes and kinetics of propanil following acute self-poisoning: a prospective case series
Roberts, D. M., Heilmair, R., Buckley, N. A., Dawson, A. H., Fahim, M., Eddleston, M., & Eyer, P. (2009) · BMC Clinical Pharmacology · doi:10.1186/1472-6904-9-3 · Cited by 60
Shamir, M. Y., Avramovich, A., & Smaka, T. J. (2011) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318233041a · Cited by 59
Fatal Sodium Nitrite Poisoning: Key Considerations for Prehospital Providers
Neth, M. R., Love, J. S., Horowitz, B. Z., Shertz, M. D., Sahni, R., & Daya, M. R. (2020) · Prehospital Emergency Care · doi:10.1080/10903127.2020.1838009 · Cited by 57
Coquin, J., Dewitte, A., Manach, Y. L., Caujolle, M., Joannès-Boyau, O., Fleureau, C., Janvier, G., & Ouattara, A. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e318258fb4f · Cited by 57
Gehring, H., Dümbgen, L., Peterlein, M., Hagelberg, S., & DIBBELT, L. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000268713.58174.cc · Cited by 56
Inhalation burn injury in children
Fidkowski, C. W., Fuzaylov, G., Sheridan, R. L., & Coté, C. J. (2009) · Pediatric Anesthesia · doi:10.1111/j.1460-9592.2008.02884.x · Cited by 56
Accuracy of Carboxyhemoglobin Detection by Pulse CO-Oximetry During Hypoxemia
Feiner, J., Rollins, M. D., Sall, J. W., Eilers, H., Au, P., & Bickler, P. E. (2013) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31828610a0 · Cited by 55
The measurement of carboxyhemoglobin and methemoglobin using a non-invasive pulse CO-oximeter
Zaouter, C., & Zavorsky, G. S. (2012) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2012.05.010 · Cited by 54
Carboxyhemoglobin Levels Induced by Cigarette Smoking Outdoors in Smokers
Schimmel, J., George, N. R., Schwarz, J., Yousif, S., Suner, S., & Hack, J. B. (2017) · Journal of Medical Toxicology · doi:10.1007/s13181-017-0645-1 · Cited by 52
Severe Methemoglobinemia Detected by Pulse Oximetry
Annabi, E. H., & Barker, S. J. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318172af73 · Cited by 51
Self-citationPulse oximetry methods: opportunities and limitations
Гаранин, А. А., Dyachkov, V. A., Рубаненко, А. О., Reprintseva, O. A., & Duplyakov, D. V. (2023) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2023-5467 · Cited by 51
Acquired Methemoglobinemia Revisited
Trapp, L. D., & Will, J. (2010) · Dental Clinics of North America · doi:10.1016/j.cden.2010.06.007 · Cited by 51
Culnan, D. M., Craft-Coffman, B., Bitz, G. H., Capek, K. D., Tu, Y., Lineaweaver, W. C., & Kuhlmann-Capek, M. J. (2018) · Annals of Plastic Surgery · doi:10.1097/sap.0000000000001351 · Cited by 48
Pelclová, D., Zacharov, S., Ždímal, V. (., Fenclová, Z., Vlčková, Š., Syslová, K., Kuzma, M. (., Navrátil, T. (., Komarc, M., & Kačer, P. (2015) · Clinical Toxicology · doi:10.3109/15563650.2015.1024953 · Cited by 47
Emergency Department Management of Suspected Carbon Monoxide Poisoning: Role of Pulse CO-Oximetry
Sebbane, M., Claret, P., Mercier, G., Lefebvre, S., Théry, R., Dumont, R., Maillé, M., Richard, J.-P., Eledjam, J., & Coussaye, J.-E. D. L. (2013) · Respiratory Care · doi:10.4187/respcare.02313 · Cited by 47
False Positive Rate of Carbon Monoxide Saturation by Pulse Oximetry of Emergency Department Patients
Weaver, L. K., Churchill, S. K., Deru, K., & Cooney, D. (2013) · Respiratory Care · doi:10.4187/respcare.01744 · Cited by 45
Recent advances in pulse oximetry
Cannesson, M., & Talke, P. (2009) · F1000 Medicine Reports · doi:10.3410/m1-66 · Cited by 44
Mostafazadeh, B., Pajoumand, A., Farzaneh, E., Aghabiklooei, A., & Rasouli, M. R. (2010) · Journal of Medical Toxicology · doi:10.1007/s13181-010-0121-7 · Cited by 42
Chee, K., Nilson, D. C., Partridge, R. A., Hughes, A. M., Suner, S., Sucov, A., & Jay, G. D. (2008) · Clinical Toxicology · doi:10.1080/15563650701725110 · Cited by 41
Clarke, S. F. J., Keshishian, C., Murray, V. S. G., Kafatos, G., Ruggles, R., Coultrip, E., Oetterli, S., Earle, D., Ward, P., Bush, S., et al. (2012) · BMJ Open · doi:10.1136/bmjopen-2012-000877 · Cited by 39
Hampson, N. B. (2012) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2012.03.026 · Cited by 38
Prevention of postpartum smoking relapse in mothers of infants in the neonatal intensive care unit
Phillips, R. M., Merritt, T. A., Goldstein, M. R., Deming, D. D., Slater, L. E., & Angeles, D. M. (2012) · Journal of Perinatology · doi:10.1038/jp.2011.106 · Cited by 37
Caboot, J. B., Jawad, A. F., McDonough, J. M., Bowdre, C. Y., Arens, R., Marcus, C. L., Mason, T. B. A., Smith‐Whitley, K., Ohene‐Frempong, K., & Allen, J. L. (2012) · Pediatric Pulmonology · doi:10.1002/ppul.22504 · Cited by 37
Towards a novel single-LED pulse oximeter based on a multispectral sensor for IoT applications
Chong, A. V., Terosiet, M., Histace, A., & Romain, O. (2018) · Microelectronics Journal · doi:10.1016/j.mejo.2018.03.005 · Cited by 36
HESS, D. R. (2016) · Respiratory Care · doi:10.4187/respcare.05208 · Cited by 34
Feasibility of Intelligent Monitoring of Construction Workers for Carbon Monoxide Poisoning
Forsyth, J. B., Martin, T. L., Young-Corbett, D. E., & Dorsa, E. (2012) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2012.2197390 · Cited by 33
Arterial Puncture and Cannulation
MILZMAN, D. P., & Janchar, T. (2010) · Elsevier eBooks · doi:10.1016/b978-1-4160-3623-4.00020-1 · Cited by 33
Environmental sustainability in the operating room: A worldwide survey among anaesthesiologists
González‐Pizarro, P., Koch, S., Muret, J. C., Trinks, A., Brazzi, L., Barbero, F. R., Sebastian, J. D., & Struys, M. M. R. F. (2023) · European Journal of Anaesthesiology Intensive Care · doi:10.1097/ea9.0000000000000025 · Cited by 31
Fundamental Principles of Monitoring Instrumentation
Szocik, J., Barker, S. J., & Tremper, K. K. (2010) · Elsevier eBooks · doi:10.1016/b978-0-443-06959-8.00038-8 · Cited by 30
Self-citationPulse Oximetry in Emergency Medicine
Callahan, J. M. (2008) · Emergency Medicine Clinics of North America · doi:10.1016/j.emc.2008.08.006 · Cited by 30
S2k guideline diagnosis and treatment of carbon monoxide poisoning
Jüttner, B., Busch, H.-J., Callies, A., Dormann, H., Jänisch, T., Kaiser, G., Körner-Göbel, H., Kluba, K., Kluge, S., Leidel, B. A., et al. (2021) · German medical science · doi:10.3205/000300 · Cited by 30
Noninvasive Measurement of Carboxyhemoglobin: How Accurate Is Accurate Enough?
Maisel, W. H., & Lewis, R. J. (2010) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2010.05.025 · Cited by 30
Practical Application of Local Anesthetics
Culp, W. C., & Culp, W. C. (2010) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2010.10.005 · Cited by 30
Niwayama, M., Suzuki, H., Yamashita, T., & Yasuda, Y. (2012) · The Journal of Japanese College of Angiology · doi:10.7133/jca.52.211 · Cited by 28
A power-efficient multi-channel PPG ASIC with 112dB receiver DR for pulse oximetry and NIRS
Schönle, P., Fateh, S., Burger, T., & Huang, Q. (2017) · Custom Integrated Circuits Conference · doi:10.1109/cicc.2017.7993704 · Cited by 25
Determination of blood volume by pulse CO-oximetry
Lalande, S., Kelsey, J. W., Joyner, M. J., & Johnson, B. D. (2011) · Physiological Measurement · doi:10.1088/0967-3334/33/1/19 · Cited by 25
Papin, M., Latour, C., Leclère, B., & Javaudin, F. (2023) · European Journal of Emergency Medicine · doi:10.1097/mej.0000000000001043 · Cited by 25
Anesthesia-Related Carbon Monoxide Exposure: Toxicity and Potential Therapy
Levy, R. J. (2016) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001461 · Cited by 25
Respiratory Monitoring During Mechanical Ventilation: The Present and the Future
Roshdy, A. (2023) · Journal of Intensive Care Medicine · doi:10.1177/08850666231153371 · Cited by 25
Lam, N., Nicas, M., Ruiz-Mercado, I., Thompson, L. M., Romero, C., & Smith, K. R. (2011) · Journal of Environmental Monitoring · doi:10.1039/c1em10172b · Cited by 25
Reliability and validity of non‐invasive determined haemoglobin mass and blood volumes
Fagoni, N., Andersen, A. B., Oberholzer, L., Haider, T., Lundby, A. M., & Lundby, C. (2017) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12406 · Cited by 24
Hullin, T., Aboab, J., Desseaux, K., Chevret, S., & Annane, D. (2017) · PLoS ONE · doi:10.1371/journal.pone.0174672 · Cited by 24
Toxin-induced Respiratory Distress
McKay, C. A. (2013) · Emergency Medicine Clinics of North America · doi:10.1016/j.emc.2013.09.003 · Cited by 24
Agarwal, N., Nagel, R. L., & Prchal, J. T. (2009) · Cambridge University Press eBooks · doi:10.1017/cbo9780511596582.034 · Cited by 23
Convolutional Neural Networks for Spectroscopic Analysis in Retinal Oximetry
DePaoli, D. T., Tossou, P., Parent, M., Sauvageau, D., & Côté, D. C. (2019) · Scientific Reports · doi:10.1038/s41598-019-47621-7 · Cited by 22
Development of a fractional multi-wavelength pulse oximetry algorithm
Urpalainen, K. (2011) · Aaltodoc (Aalto University) · Cited by 22
Benzocaine-induced methaemoglobinaemia in an adolescent with sepsis
Jayapal, A., Rosario, D. C., Sanchez, J. L., & Ambati, S. R. (2022) · BMJ Case Reports · doi:10.1136/bcr-2021-248013 · Cited by 22
Coquin, J., Bertarrex, A., Dewitte, A., Lefèvre, L. M., Joannès-Boyau, O., Fleureau, C., Winnock, S., Leuillet, S., Janvier, G., & Ouattara, A. (2013) · Anesthesiology · doi:10.1097/aln.0b013e3182833fcc · Cited by 21
Wavelength selection method based on test analysis of variance: application to oximetry
Li, W., Lin, L., & Li, G. (2014) · Analytical Methods · doi:10.1039/c3ay41601a · Cited by 21
Victim of Carbon Monoxide Poisoning Identified by Carbon Monoxide Oximetry
von Roth, D., Hubmann, N., Havel, C., Herkner, H., Schreiber, W., & Laggner, A. N. (2009) · Journal of Emergency Medicine · doi:10.1016/j.jemermed.2009.05.017 · Cited by 20
Second‐hand smoking and carboxyhemoglobin levels in children: a prospective observational study
Yee, B. E., Ahmed, M. I., Brugge, D., FARRELL, M., LOZADA, G., IDUPAGANTHI, R., & Schumann, R. (2009) · Pediatric Anesthesia · doi:10.1111/j.1460-9592.2009.03192.x · Cited by 20
Ideation and assessment of a nitric oxide delivery system for spontaneously breathing subjects
Gianni, S., Morais, C. C. A., Larson, G. M., Pinciroli, R., Carroll, R. W., Yu, B., Zapol, W. M., & Berra, L. M. (2020) · Nitric Oxide · doi:10.1016/j.niox.2020.08.004 · Cited by 19
Mashayekhian, M., Hassanian‐Moghaddam, H., Rahimi, M., Zamani, N., Aghabiklooei, A., & Shadnia, S. (2016) · Basic & Clinical Pharmacology & Toxicology · doi:10.1111/bcpt.12571 · Cited by 18
CO and NO pulmonary diffusing capacity during pregnancy: Safety and diagnostic potential
Zavorsky, G. S., Blood, A. B., Power, G. G., Longo, L. D., Artal, R., & Vlastos, E. J. (2010) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2010.02.001 · Cited by 18
Continuous noninvasive hemoglobin monitoring: The standard of care and future impact*
Kost, G. J., & Tran, N. K. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182266013 · Cited by 18
Ruckman, J. S. (2011) · OpenCommons - UConn (University of Connecticut) · Cited by 17
Gutenberg, L. L., Chen, J., & Trapp, L. D. (2013) · Anesthesia Progress · doi:10.2344/0003-3006-60.3.99 · Cited by 17
Pulse-Oximetric Measurement of Prilocaine-Induced Methemoglobinemia in Regional Anesthesia
Soeding, P., Deppe, M., & Gehring, H. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181eb6239 · Cited by 16
O’Reilly, M. (2010) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2010.08.016 · Cited by 16
Masimo Rad-57 Pulse CO-Oximeter™ for noninvasive carboxyhemoglobin measurement
Suner, S., & McMurdy, J. W. (2009) · Expert Review of Medical Devices · doi:10.1586/17434440.6.2.125 · Cited by 16
In the Spotlight: BioInstrumentation
Yamakoshi, K.-I. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2089616 · Cited by 14
Hernández-Quintanar, L. F., Fabila-Bustos, D. A., Hernández-Chávez, M., Valor, A., de la Rosa, J., & Stolik, S. (2019) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2019.105237 · Cited by 14
Kulcke, A., Feiner, J., Menn, I., Holmer, A., Hayoz, J., & Bickler, P. E. (2016) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001219 · Cited by 14
In the Spotlight: BioInstrumentation
Yamakoshi, K. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2034696 · Cited by 14
Bodenstein, M., Wang, H., Boehme, S., Baumgardner, J. E., Duenges, B., Vogt, A. P., David, M., & Markstaller, K. (2010) · Experimental Lung Research · doi:10.3109/01902140903575971 · Cited by 14
What's New in Pediatric Carbon Monoxide Poisoning?
Baum, C. R. (2008) · Clinical Pediatric Emergency Medicine · doi:10.1016/j.cpem.2007.11.002 · Cited by 14
Three-wavelength murine photoplethysmography for estimation of vascular gold nanorod concentration
Michalak, G. J., Schwartz, J. A., Goodrich, G. P., & O’Neal, D. P. (2010) · Optics Express · doi:10.1364/oe.18.026535 · Cited by 14
Use of Pulse Co-Oximetry as a Screening and Monitoring Tool in Mass Carbon Monoxide Poisoning
Bledsoe, B. E., Nowicki, K. D., Creel, J. H., Carrison, D., & Severance, H. W. (2009) · Prehospital Emergency Care · doi:10.3109/10903120903349853 · Cited by 14
Strojnik, M., & Паез, Г. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.10.108001 · Cited by 13
Diagnostic Performance of Carbon Monoxide Testing by Pulse Oximetry in the Emergency Department
Villalba, N., Osborn, Z. T., Derickson, P. R., Manning, C. T., Herrington, R. R., Kaminsky, D. A., & Freeman, K. (2019) · Respiratory Care · doi:10.4187/respcare.06365 · Cited by 13
Noninvasive Carbon Monoxide Detection: Insufficient Evidence for Broad Clinical Use
Wilcox, S. R., & Richards, J. B. (2013) · Respiratory Care · doi:10.4187/respcare.02288 · Cited by 13
Air Pollution, Child Health, and Cognitive Development
Nduka, E., & Jimoh, M. O. (2024) · The Journal of Development Studies · doi:10.1080/00220388.2024.2420024 · Cited by 12
Applications of Optical Cardiovascular Monitoring
Lemay, M., Bertschi, M., Solà, J., Renevey, P., Genzoni, E., Proença, M., Ferrario, D., Braun, F., Parák, J., & Korhonen, I. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-819246-7.00018-8 · Cited by 12
Wu, A. H. B. (2019) · The Journal of Applied Laboratory Medicine · doi:10.1373/jalm.2018.028654 · Cited by 12
Poredoš, P., Gradišek, P., Testen, C., & Derganc, M. (2011) · Burns · doi:10.1016/j.burns.2011.05.015 · Cited by 12
Metadata
- Authors
- Barker, S. J., Curry, J., Redford, D., & Morgan, S.
- Venue
- Anesthesiology
- Published
- 2006-11-01
- Volume
- 105
- Issue
- 5
- Pages
- 892-897
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2123754678
- Cited by
- 238
- References
- 16
- FWCI
- 9.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.