Immune Response to Synthetic Materials: Sensitization of Patients Receiving Orthopaedic Implants
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Metallic orthopaedic devices are composed of elements that are known to be skin sensitizers in the general population. There is concern about the possibility of sensitivity reactions in patients bearing these implants. Blood samples were drawn from 22 patients having primary total joint replacement and who had no known prior metal allergies or exposure. Repeat blood samples were drawn 3 months to 1 year later. All preoperative blood samples showed no immune reactions against titanium, cobalt, chromium, or nickel ion solutions in a leukocyte migration inhibition test. Thirty two percent (7 of 22) of the patients developed sensitivity to at least 1 of the antigens, but only 5 percent (1 of 22) developed a severe reaction. Review of the literature and these studies has indicated that such reactions can occur. However, the incidence seems to be very low.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reactions of the articular capsule to wear products of artificial joint prostheses
Willert, H. ‐., & Semlitsch, M. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110202 · Cited by 822
Sensitivity to titanium. A cause of implant failure?
Lalor, P., Revell, P., Gray, A., Wright, S., Railton, G., & Freeman, M. (1991) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.73b1.1991768 · Cited by 393
The Ionization of Metal Implants in Living Tissues
Ferguson, A. B., Laing, P. G., & Hodge, E. S. (1960) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-196042010-00007 · Cited by 258
Nickel, cobalt and chromium in consumer products: a role in allergic contact dermatitis?
Basketter, D. A., Briatico‐Vangosa, G., Kaestner, W., Lally, C., & Bontinck, W. J. (1993) · Contact Dermatitis · doi:10.1111/j.1600-0536.1993.tb03318.x · Cited by 257
The skin immune system Its cellular constituents and their interactions
Bos, J. D., & Kapsenberg, M. L. (1986) · Immunology Today · doi:10.1016/0167-5699(86)90111-8 · Cited by 233
Composition and in vitro corrosion of orthodontic appliances
Grimsdottir, M. R., Gjerdet, N. R., & Hensten-Pettersen, A. (1992) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/0889-5406(92)70127-v · Cited by 180
Systemic effects of biomaterials
Blac, J. (1984) · Biomaterials · doi:10.1016/0142-9612(84)90061-9 · Cited by 166
Kanerva, L., Estiander, T., Jolanki, R., & Tarvainijn, K. (1993) · Contact Dermatitis · doi:10.1111/j.1600-0536.1993.tb03430.x · Cited by 127
Detection of antibodies against corrosion products in patients after CoCr total joint replacements
Yang, J. M., & Merritt, K. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820281102 · Cited by 93
Self-citationPrevalence of contact allergy by sex, race and age
Goh, C. L. (1986) · Contact Dermatitis · doi:10.1111/j.1600-0536.1986.tb01232.x · Cited by 89
Aluminum-induced granulomas in a tattoo
McFadden, N., Lyberg, T., & Hensten‐Pettersen, A. (1989) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(89)70104-3 · Cited by 84
Lymphocyte response to polymethylmethacrylate in loose total hip prostheses
Albarova, J. G., Laclériga, A., Barrios, C., & Cañadell, J. (1992) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.74b6.1447242 · Cited by 69
Merritt, K. (1984) · Biomaterials · doi:10.1016/0142-9612(84)90066-8 · Cited by 57
Self-citationThe Role of Langerhans Cells and Keratinocytes in Epidermal Immunity
Choi, K. L., & Sauder, D. N. (1986) · Journal of Leukocyte Biology · doi:10.1002/jlb.39.3.343 · Cited by 52
Proliferation of nickel-sensitive human lymphocytes by corrosion products of orthodontic appliances
Grímsdóttir, M. R., Hensten‐Pettersen, A., & Kullmann, A. (1994) · Biomaterials · doi:10.1016/0142-9612(94)90236-4 · Cited by 34
Patch test reactions to aluminium
Meding, B., Augustsson, A., & Hansson, C. (1984) · Contact Dermatitis · doi:10.1111/j.1600-0536.1984.tb00347.x · Cited by 34
Cited by
A Review on Biomedical Titanium Alloys: Recent Progress and Prospect
Zhang, L., & Chen, L. (2019) · Advanced Engineering Materials · doi:10.1002/adem.201801215 · Cited by 1,100
Metal Sensitivity in Patients with Orthopaedic Implants
Hallab, N., Merritt, K., & Jacobs, J. J. (2001) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200103000-00017 · Cited by 935
Self-citationBiomedical Applications of Titanium Alloys: A Comprehensive Review
Marin, E., & Lanzutti, A. (2023) · Materials · doi:10.3390/ma17010114 · Cited by 489
Metal Allergy—A Review on Exposures, Penetration, Genetics, Prevalence, and Clinical Implications
Thyssen, J. P., & Menné, T. (2010) · Chemical Research in Toxicology · doi:10.1021/tx9002726 · Cited by 398
Wear particles, periprosthetic osteolysis and the immune system
Goodman, S. B. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.06.035 · Cited by 340
“One patient developed a severe reaction [20].”
Metadata
- Authors
- Merritt, K., & Rodrigo, J. J.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1996-05
- Volume
- 326
- Issue
- 326
- Pages
- 71-79
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2054595138
- Cited by
- 222
- References
- 16
- FWCI
- 1.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.