Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 412

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Successful Transplantation of Bioengineered Tissue Replacements in Patients with Ocular Surface Disease

Schwab, Ivan R., Reyes, Merle, Isseroff, R. Rivkah·2000·Cornea

Abstract

PURPOSE: To bioengineer a corneal surface replacement using ex vivo expanded, cultured corneal epithelial stem cells seeded on a matrix derived from amniotic membrane and use this bioengineered graft to manage difficult ocular surface disease. METHODS: Fourteen patients with ocular surface disease unresponsive to standard medical and surgical treatments, including seven patients with presumed limbal stem cell deficiency were chosen for transplantation of a bioengineered composite corneal surface in eye each. Presumed corneal stem cells were harvested from either the patient's or related donor's limbus, expanded ex vivo, and cultivated on a carrier of modified human amniotic membrane. The resulting composite cultured tissue was transplanted to the ocular surface of the diseased eye, from which the abnormal tissue had been surgically removed. Ten patients received autologous grafts, and four received allogeneic grafts. RESULTS: A successful outcome, defined as restoration or improvement of vision, along with maintenance of corneal re-epithelialization and absence or recurrence of surface disease was obtained in 6 of the 10 patients with autologous procedures and in all 4 allogeneic transplants. Follow-up ranged 6-19 months with a mean of 13 months. CONCLUSIONS: This novel technique documents that presumed corneal epithelial stem cells can be harvested safely from the limbus, expanded successfully in vitro, and grown on denuded amniotic membrane. The resultant composite cultured tissue can be transplanted and appears to successfully manage eyes with difficult ocular surface disease, including those with stem cell deficiency. This technique minimizes the threat of damage or depletion to the contralateral or donor limbus.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003226-200007000-00003

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 412

Metadata

Authors
Schwab, I. R., Reyes, M., & Isseroff, R. R.
Venue
Cornea
Published
2000-07
Volume
19
Issue
4
Pages
421-426
ISSN
0277-3740 (ISSN-L)
OpenAlex
W1979623069
Cited by
412
References
18
FWCI
15.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Successful Transplantation of Bioengineered Tissue Replacements in Patients with Ocular Surface Disease. https://app.cochat.ai/papers/10.1097/00003226-200007000-00003
The paper
Schwab, I. R., Reyes, M., & Isseroff, R. R. (2000). Successful Transplantation of Bioengineered Tissue Replacements in Patients with Ocular Surface Disease. Cornea. https://doi.org/10.1097/00003226-200007000-00003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.