Unreliability of blood pressure and heart rate to evaluate cardiac output in emergency resuscitation and critical illness
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To evaluate the reliability of the vital signs to evaluate circulatory stability as reflected by cardiac index. DESIGN: Descriptive analysis based on data gathered prospectively, using a predetermined protocol. SETTING: University-run county hospital, with a large trauma service. PATIENTS: Sixty-one high-risk trauma patients with accidental injury who were studied immediately after admission to the Emergency Department, and subsequently, 163 critically ill postoperative ICU patients. INTERVENTIONS: Standard fluid therapy, usually crystalloids, but occasionally packed red cell transfusions and colloids, as indicated by clinical criteria. MEASUREMENTS AND RESULTS: Arterial BP was measured by pressure transducer and arterial catheter; heart rate (HR) was measured by electrocardiograph signal, and cardiac output was measured by thermodilution. In sudden severe hypovolemic hypotension, the mean arterial pressure (MAP) nadir (lowest) roughly correlated (r2 = .25) with flow, but there was poor correlation (r2 = .0001) when all pressure and flow values were evaluated. The pressure and flow values were obtained throughout the course of the hypotensive episodes during the initial resuscitation in ICU patients and during terminal illnesses. CONCLUSIONS: Observations at the time of acute severe hypotensive crises that show rough correlation of MAP and cardiac index should not be extrapolated throughout the entire hypotensive period or to other less extreme clinical situations. The stress response to hypovolemia, with endogenous catecholamines and neural mechanisms, tends to maintain arterial pressure in the face of decreasing flow for a variable period of time. However, when these mechanisms are overwhelmed by prolonged hypovolemia, the pressure decreases precipitously, but not synchronously, with flow. We conclude that blood flow cannot reliably be inferred from arterial pressure and heart rate measurements until extreme hypotension occurs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Early lactate clearance is associated with improved outcome in severe sepsis and septic shock*
Nguyen, H. B., Rivers, E. P., Knoblich, B. P., Jacobsen, G., Muzzin, A., Ressler, J. A., & Tomlanovich, M. C. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000132904.35713.a7 · Cited by 1,228
Etiology and Therapeutic Approach to Elevated Lactate Levels
Andersen, L. W., Mackenhauer, J., Roberts, J. C., Berg, K. M., Cocchi, M. N., & Donnino, M. W. (2013) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2013.06.012 · Cited by 731
Moore, C. L., Rose, G. A., Tayal, V. S., Sullivan, D. M., Arrowood, J. A., & Kline, J. A. (2002) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2002.tb00242.x · Cited by 361
Occult hypoperfusion and mortality in patients with suspected infection
Howell, M. D., Donnino, M., Clardy, P., Talmor, D., & Shapiro, N. I. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0680-5 · Cited by 356
Nguyen, H. B., Rivers, E. P., Abrahamian, F. M., Moran, G. J., Abraham, E., Trzeciak, S., Huang, D. T., Osborn, T., Stevens, D., & Talan, D. A. (2006) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2006.02.015 · Cited by 356
Rady, M. Y., Smithline, H. A., Blake, H., Nowak, R., & Rivers, E. (1994) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(94)70279-9 · Cited by 334
Fluid Response Evaluation in Sepsis Hypotension and Shock
Douglas, I. S., Alapat, P. M., Corl, K. A., Exline, M. C., Forni, L. G., Holder, A. L., Kaufman, D. A., Khan, A., Levy, M. M., Martin, G. S., et al. (2020) · Chest · doi:10.1016/j.chest.2020.04.025 · Cited by 271
Hypotension Begins at 110 mm Hg: Redefining “Hypotension” With Data
Eastridge, B. J., Salinas, J., McManus, J. G., Blackburn, L., Bugler, E. M., Cooke, W. H., Concertino, V. A., Wade, C. E., & Holcomb, J. B. (2007) · Journal of Trauma: Injury, Infection & Critical Care · doi:10.1097/ta.0b013e31809ed924 · Cited by 268
Rady, M. Y., Rivers, E. P., & Nowak, R. M. (1996) · The American Journal of Emergency Medicine · doi:10.1016/s0735-6757(96)90136-9 · Cited by 261
Sonographic measurement of the inferior vena cava as a marker of blood loss
Lyon, M., Blaivas, M., & Brannam, L. (2005) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2004.01.004 · Cited by 258
Central venous oxygen saturation monitoring in the critically ill patient
Rivers, E. P., Ander, D. S., & Powell, D. (2001) · Current Opinion in Critical Care · doi:10.1097/00075198-200106000-00011 · Cited by 242
Redefining hypotension in traumatic brain injury
Berry, C., Ley, E. J., Bukur, M., Malinoski, D., Margulies, D. R., Mirocha, J., & Salim, A. (2012) · Injury · doi:10.1016/j.injury.2011.08.014 · Cited by 180
“Previous studies have demonstrated a higher likelihood for automated devices to overestimate the true manual blood pressure by approximately 10 mm Hg.22,23 Survival differences in gender,24–26 race,27 insurance status,28 and pre-hospital alcohol29–31use may contribute to differences in admission SBP.”
BackgroundInfluentialNew Vitals After Injury: Shock Index for the Young and Age × Shock Index for the Old
Zarzaur, B. L., Croce, M. A., Fischer, P. E., Magnotti, L. J., & Fabian, T. C. (2008) · Journal of Surgical Research · doi:10.1016/j.jss.2008.03.025 · Cited by 179
“used by the authors [5, 23].”
Rivers, E. P. (2005) · Canadian Medical Association Journal · doi:10.1503/cmaj.050632 · Cited by 173
Shock Index as a Marker for Significant Injury in Trauma Patients
King, R. W., Plewa, M. C., Buderer, N. M. F., & Knotts, F. B. (1996) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.1996.tb03351.x · Cited by 172
Dünser, M. W., Takala, J., Brunauer, A., & Bakker, J. (2013) · Critical Care · doi:10.1186/cc12727 · Cited by 169
“Although critical arterial blood pressure levels have been proposed for diverse shock populations [6,7], the inter-individual variation of the correlation between arterial pressure and systemic blood fl ow is substantial (Figure 2) [8].”
BackgroundFunctional Hemodynamic Monitoring
Pinsky, M. R. (2015) · Critical Care Clinics · doi:10.1016/j.ccc.2014.08.005 · Cited by 168
“Previous work has documented that these single vital signs are not sensitive at identifying shock until advanced [12].”
BackgroundPredictors of the complication of postintubation hypotension during emergency airway management
Heffner, A. C., Swords, D. S., Nussbaum, M. L., Kline, J. A., & Jones, A. E. (2012) · Journal of Critical Care · doi:10.1016/j.jcrc.2012.04.022 · Cited by 156
“Conventional vital signs are poorly correlated with systemic hemodynamics and oxygen delivery [8].”
BackgroundEarly markers of major adverse events in children after cardiac operations
Duke, T., Butt, W., South, M., & Karl, T. R. (1997) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(97)70018-7 · Cited by 152
The frequency and significance of postintubation hypotension during emergency airway management
Heffner, A. C., Swords, D., Kline, J. A., & Jones, A. E. (2012) · Journal of Critical Care · doi:10.1016/j.jcrc.2011.08.011 · Cited by 137
Trivedi, S., Demirci, O., Arteaga, G., Kashyap, R., & Smischney, N. J. (2015) · Journal of Critical Care · doi:10.1016/j.jcrc.2015.04.013 · Cited by 55
“hemodynamic instability, but the validity and reliability of these signs in determining instability are questionable [4].”
Background
Metadata
- Authors
- WO, C. C. J., SHOEMAKER, W. C., APPEL, P. L., BISHOP, M. H., KRAM, H. B., & HARDIN, E.
- Venue
- Critical Care Medicine
- Published
- 1993-02
- Volume
- 21
- Issue
- 2
- Pages
- 218-223
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2085304298
- Cited by
- 321
- References
- 0
- FWCI
- 7.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.