Abstract
OBJECTIVE: The objective of this study was to determine the relationship between electrically evoked whole nerve action potential (EAP) and electrical auditory brain stem response (EABR) thresholds and MAP threshold (T-level) and maximum comfort level (C-level) for subjects who use the Nucleus 24 cochlear implant system. DESIGN: Forty-four adult Nucleus 24 cochlear implant users participated in this study. EAP thresholds were recorded using the Neural Response Telemetry System developed by Cochlear Corporation. EABR thresholds were measured for a subset of 14 subjects using standard evoked potential techniques. These physiologic thresholds were collected on a set of five electrodes spaced across the cochlea, and were then compared with behavioral measures of T-level and C-level used to program the speech processor. RESULTS: EAP thresholds were correlated with MAP T- and C-levels; however, the correlation was not strong. A technique for improving the correlation by combining measures of T- and C-levels made on one electrode with the EAP thresholds was presented. Correlations between predicted and measured T- and C-levels using this technique were 0.83 and 0.77, respectively. Similar results were obtained using the EABR thresholds for a smaller set of subjects. In general, EABR thresholds were recorded at levels that were approximately 4.7 programming units lower than EAP thresholds. CONCLUSIONS: Either EAP or EABR thresholds can be used in combination with a limited amount of behavioral information to predict MAP T- and C-levels with reasonable accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Abbas, P. J., Brown, C. J., Shallop, J. K., Firszt, J. B., Hughes, M. L., Hong, S. H., & Staller, S. J. (1999) · Ear and Hearing · doi:10.1097/00003446-199902000-00005 · Cited by 322
Self-citationElectrically evoked whole-nerve action potentials: Data from human cochlear implant users
Brown, C. J., Abbas, P. J., & Gantz, B. (1990) · The Journal of the Acoustical Society of America · doi:10.1121/1.399716 · Cited by 303
Self-citationBrown, C., Abbas, P. J., Fryauf-Bertschy, H., Kelsay, D. M. R., & Gantz, A. B. J. (1994) · Ear and Hearing · doi:10.1097/00003446-199404000-00006 · Cited by 127
Self-citationPreliminary experience with neural response telemetry in the nucleus CI24M cochlear implant.
Brown, C., Abbas, P. J., & Gantz, B. J. (1998) · PubMed · Cited by 127
Self-citationBrown, C., Abbas, P. J., Borland, J., & Bertschy, M. (1996) · Journal of Speech Language and Hearing Research · doi:10.1044/jshr.3903.453 · Cited by 102
Self-citation
Cited by
Hughes, M. L., Vander Werff, K. R., Brown, C. J., Abbas, P. J., Kelsay, D. M. R., Teagle, H. F. B., & Lowder, M. W. (2001) · Ear and Hearing · doi:10.1097/00003446-200112000-00004 · Cited by 271
Self-citationThe Development of the Nucleus® Freedom™ Cochlear Implant System
Patrick, J. F., Busby, P. A., & Gibson, P. J. (2006) · Trends in Amplification · doi:10.1177/1084713806296386 · Cited by 196
“Fitting methods based on objective measures, such as ECAP, ESRT, and EABR, combined with limited behavioral measures have also been successfully used.(22,25,117,118) The Custom Sound Suite supports streamlined fitting using behavioral and electrophysiologic measures.”
Comparison of EAP Thresholds with MAP Levels in the Nucleus 24 Cochlear Implant: Data from Children
Hughes, M. L., Brown, C. J., Abbas, P. J., Wolaver, A. A., & Gervais, J. P. (2000) · Ear and Hearing · doi:10.1097/00003446-200004000-00010 · Cited by 185
Self-citationSmoorenburg, G. F., Willeboer, C., & van Dijk, J. E. (2002) · Audiology and Neurotology · doi:10.1159/000066154 · Cited by 162
“So far, research on ECAPs in human subjects has been focussed on optimization of the ECAP measurement itself and on relations between ECAP parameters and psychophysical measures [Brown et al., 1996, 1998, 2000; Abbas et al., 1999; Hughes et al., 2000].”
MethodCochlear-implant spatial selectivity with monopolar, bipolar and tripolar stimulation
Zhu, Z., Tang, Q., Zeng, F.-G., Guan, T., & Ye, D. (2012) · Hearing Research · doi:10.1016/j.heares.2011.11.005 · Cited by 115
“A forward-masking subtraction paradigm was utilized to eliminate artifact and to record ECAP signals (Abbas et al., 2004; Abbas et al., 1999; Brown et al., 2000; Cohen et al., 2003; de Sauvage et al., 1983; Dillier et al., 2002).”
Method
Metadata
- Authors
- Brown, C. J., Hughes, M. L., Luk, B., Abbas, P. J., Wolaver, A., & Gervais, J.
- Venue
- Ear and Hearing
- Published
- 2000-04
- Volume
- 21
- Issue
- 2
- Pages
- 151-163
- ISSN
- 0196-0202 (ISSN-L)
- OpenAlex
- W2023088562
- Cited by
- 275
- References
- 5
- FWCI
- 4.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.