Defining Epileptogenic Foci: Past, Present, Future
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
There is a direct relationship between the geometry (location, area, and orientation) of cortex-generating epileptiform discharges and resultant spike or seizure voltage fields at the scalp. Epileptogenic foci have been localized traditionally with EEG by identifying the negative field maximum (e.g., a phase reversal between adjacent bipolar channels). However, it is the shape of the entire voltage field over the head, including both negative and positive maxima, which provides information necessary to characterize the focus properly. Source location and orientation can be inferred from spike or seizure voltage topography, however, three-dimensional visualization can be obtained from mathematical source models, such as an equivalent dipole. Recent investigations have shown that dipole models can identify the location of epileptogenic foci with sub-lobar precision. Accuracy is enhanced by using additional electrodes, particularly on the lower half of the head, and by measuring their location. Realistic head models obtained from three-dimensional reconstructions of MR images can overcome errors introduced by simple spherical models of the cranium. Co-registering EEG voltage topography and source models with a patient's own cerebral anatomy will make EEG an unparalleled functional imaging technique for defining epileptogenic foci.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Realistic conductivity geometry model of the human head for interpretation of neuromagnetic data
Hamalainen, M. S., & Sarvas, J. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.16463 · Cited by 989
Evoked dipole source potentials of the human auditory cortex
Scherg, M., & Von Cramon, D. (1986) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(86)90014-6 · Cited by 707
Cooper, R., Winter, A. L., Crow, H. J., & Walter, W. G. (1965) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(65)90088-x · Cited by 561
On the numerical accuracy of the boundary element method (EEG application)
Meijs, J. W. H., Weier, O. W., Peters, M. J., & Van Oosterom, A. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.40805 · Cited by 305
A new interpretation of the generators of BAEP waves I–V: Results of a spatio-temporal dipole model
Scherg, M., & Von Cramon, D. (1985) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(85)90006-1 · Cited by 299
Localization of Temporal Lobe Foci by Ictal EEG Patterns
Ebersole, J. S., & Pacia, S. V. (1996) · Epilepsia · doi:10.1111/j.1528-1157.1996.tb00577.x · Cited by 278
Self-citationEvaluation of Methods for Three-Dimensional Localization of Electrical Sources in the Human Brain
Kavanagk, R. N., Darcey, T. M., Lehmann, D., & Fender, D. H. (1978) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1978.326339 · Cited by 276
Intracranial EEG Substrates of Scalp Ictal Patterns from Temporal Lobe Foci
Pacia, S. V., & Ebersole, J. S. (1997) · Epilepsia · doi:10.1111/j.1528-1157.1997.tb01233.x · Cited by 253
Self-citationFunctional imaging and localization of electromagnetic brain activity
Scherg, M. (1992) · Brain Topography · doi:10.1007/bf01129037 · Cited by 253
Gloor, P. (1985) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-198510000-00002 · Cited by 244
Cited by
Michel, C. M., Murray, M. M., Lantz, G., Gonzalez, S., Spinelli, L., & Grave de Peralta, R. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.06.001 · Cited by 1,655
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
A brief introduction to the use of event-related potentials in studies of perception and attention
Woodman, G. F. (2010) · Attention Perception & Psychophysics · doi:10.3758/app.72.8.2031 · Cited by 632
Nunez, P. L., Wingeier, B. M., & Silberstein, R. B. (2001) · Human Brain Mapping · doi:10.1002/hbm.1030 · Cited by 510
Toward a quantitative description of large-scale neocortical dynamic function and EEG
Nunez, P. L. (2000) · Behavioral and Brain Sciences · doi:10.1017/s0140525x00003253 · Cited by 467
Intracranial EEG Substrates of Scalp EEG Interictal Spikes
Tao, J. X., Ray, A., Hawes‐Ebersole, S., & Ebersole, J. S. (2005) · Epilepsia · doi:10.1111/j.1528-1167.2005.11404.x · Cited by 424
Self-citationNunez, P. L., & Silberstein, R. B. (2000) · Brain Topography · doi:10.1023/a:1026683200895 · Cited by 307
Acquiring simultaneous EEG and functional MRI
Goldman, R. I., Stern, J. M., Engel, J., & Cohen, M. S. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00456-9 · Cited by 284
EEG source localization in focal epilepsy: Where are we now?
Plummer, C., Harvey, A. S., & Cook, M. (2008) · Epilepsia · doi:10.1111/j.1528-1167.2007.01381.x · Cited by 252
Worrell, G. A., Lagerlund, T. D., Sharbrough, F. W., Brinkmann, B. H., Busacker, N. E., Cicora, K. M., & O'Brien, T. J. (2000) · Brain Topography · doi:10.1023/a:1023407521772 · Cited by 242
Evaluation of EEG localization methods using realistic simulations of interictal spikes
Grova, C., Daunizeau, J., Lina, J.-M., Bénar, C. G., Benali, H., & Gotman, J. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.08.053 · Cited by 233
Electromagnetic Inverse Solutions in Anatomically Constrained Spherical Head Models
Spinelli, L., Andino, S. G., Lantz, G., Seeck, M., & Michel, C. M. (2000) · Brain Topography · doi:10.1023/a:1026607118642 · Cited by 182
“Independent of whether equivalent dipoles or 3-dimensional current density distributions are estimated, co-registration with anatomical images is possible (e.g., George et al. 1995; Ebersole 1997; Fuchs et al. 1999).”
BackgroundLantz, G., Spinelli, L., Seeck, M., de Peralta Menendez, R. G., Sottas, C. C., & Michel, C. M. (2003) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200309000-00003 · Cited by 170
“Thus, in several studies by Ebersole (1991, 1994, 1997), sequential activation of two different dipole sources has been attributed to activation of mesiobasal and lateral temporal neocortex, respectively, an interpretation which has been verified by intracranial investigations (Ebersole et al.,…”
BackgroundIwasaki, M., Pestana, E., Burgess, R. C., Lüders, H. O., Shamoto, H., & Nakasato, N. (2005) · Epilepsia · doi:10.1111/j.0013-9580.2005.21104.x · Cited by 160
“In actual practice, however, we encounter a broad range of orientations, with the real generator extending over the cortical surface, including both gyral wall and lateral surface (7).”
BackgroundPitfalls in the dipolar model for the neocortical EEG sources
Riera, J. J., Ogawa, T., Goto, T., Sumiyoshi, A., Nonaka, H., Evans, A., Miyakawa, H., & Kawashima, R. (2012) · Journal of Neurophysiology · doi:10.1152/jn.00098.2011 · Cited by 98
Noninvasive cortical imaging of epileptiform activities from interictal spikes in pediatric patients
Lai, Y., Zhang, X., van Drongelen, W., Korhman, M., Hecox, K., Ni, Y., & He, B. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.07.026 · Cited by 22
“…localization (He et al., 1987; Ebersole 1994), the distributed source analysis (Michel et al., 1999; Huppertz 2001b; Sidman et al., 1992; Ding et al, 2007a,b; Brodbeck et al., 2010) and the localization from EEG patterns (Ebersole et al., 1996; Ebersole 1997) in both research and clinical studies.”
Background
Metadata
- Authors
- Ebersole, J. S.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 1997-11
- Volume
- 14
- Issue
- 6
- Pages
- 470-483
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W1968350252
- Cited by
- 173
- References
- 31
- FWCI
- 3.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.