CoChat

Rapid Three-Dimensional MR Imaging Using the FLASH Technique

Frahm, Jens, Haase, Axel, Matthaei, Dieter · 1986 · Journal of Computer Assisted Tomography
Cited by 267

The DOI matches its Crossref record.

Abstract

Fast low-angle shot (FLASH) imaging is a new technique for rapid magnetic resonance (MR) imaging that reduces acquisition times to seconds while retaining spatial resolution. This article deals with a three-dimensional (3D) variant of the FLASH method that allows the recording of a 3D-data set of 128 X 128 X 128 pixels within an acquisition time of only 4 min. The method is demonstrated using a 2.35 T 40 cm bore MR system. Experiments are carried out on rabbit head and human extremities. Depending on the field of view, the isotropic resolution is 1 mm or even less leading to cross-sectional images with a 1 mm slice thickness. In principle, FLASH imaging techniques are applicable to any MR system without the need of major hardware modifications. However, high-speed computers, large storage capacity, and rapid image display routines greatly facilitate an advantageous use of the 3D-FLASH variant.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004728-198603000-00046

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Frahm, J., Haase, A., & Matthaei, D.
Venue
Journal of Computer Assisted Tomography
Published
1986-03
Volume
10
Issue
2
Pages
363-368
ISSN
0363-8715 (ISSN-L)
OpenAlex
W2060591755
Cited by
267
References
0
FWCI
14.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.