Accurate Registration of Serial 3D MR Brain Images and Its Application to Visualizing Change in Neurodegenerative Disorders
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
PURPOSE: To propose and assess methods that permit the accurate and robust registration of serially acquired 3D MR scans and to demonstrate their application in neurodegenerative disorders. METHOD: 3D T1-weighted brain images were obtained on two or more occasions from 10 normal subjects and 8 patients with neurodegenerative disorders (scan intervals 3-21 months). Variants of an automated registration procedure were compared according to the goodness and robustness of match in normal subjects. Consistency was measured using scan triplets. Change was visualized by "difference overlay images." RESULTS: A multiresolution method was necessary for robust registration. Significant improvements in the registering of control scans were produced with voxel size correction (p < 0.05), matching only brain voxels (p < 0.05), and sinc interpolation (p < 0.05). Fast sinc resampling was 20 times faster than an equivalent previous method. Subvoxel accuracy was demonstrated. Difference overlay images showed little cerebral change in normal subjects; in Alzheimer disease patients, characteristic patterns of brain atrophy were observed even with scan intervals as short as 3 months. CONCLUSION: This methodology permits subvoxel comparison of routinely acquired serial 3D MR brain scans. It is a sensitive method for tracking patterns and rates of neuroanatomical change.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Folstein, M. F., Folstein, S. E., & McHugh, P. R. (1975) · Journal of Psychiatric Research · doi:10.1016/0022-3956(75)90026-6 · Cited by 88,282
McKhann, G., Drachman, D., Folstein, M., Katzman, R., Price, D., & Stadlan, E. M. (1984) · Neurology · doi:10.1212/wnl.34.7.939 · Cited by 27,915
Automatic 3D intersubject registration of MR volumetric data in standardized Talairach space
Collins, D. L., Neelin, P., Peters, T. M., & Evans, A. C. (1994) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199403000-00005 · Cited by 3,431
Rapid Automated Algorithm for Aligning and Reslicing PET Images
Woods, R. P., Cherry, S. R., & Mazziotta, J. C. (1992) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199207000-00024 · Cited by 1,912
Self-citationMRI-PET Registration with Automated Algorithm
Woods, R. P., Mazziotta, J. C., & R. Cherry, A. S. (1993) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199307000-00004 · Cited by 1,617
Self-citationAccurate Three-Dimensional Registration of CT, PET, and/or MR Images of the Brain
Pelizzari, C. A., Chen, G. T. Y., Spelbring, D. R., Weichselbaum, R. R., & Chen, C.-T. (1989) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198901000-00004 · Cited by 1,096
Visualisation and quantification of rates of atrophy in Alzheimer's disease
Fox, N. C., Freeborough, P. A., & Rossor, M. N. (1996) · The Lancet · doi:10.1016/s0140-6736(96)05228-2 · Cited by 378
Self-citationPietrzyk, U., Herholz, K., Fink, G. R., Jacobs, A., Mielke, R., Slansky, I., Würker, M., & Heiss, W. (1994) · PubMed · Cited by 318
Grimson, W. E. L., Ettinger, G. J., White, S. J., Lozano-Perez, T., Wells, W. M., & Kikinis, R. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.491415 · Cited by 316
Bergstr??m, M., Bo??thius, J., Eriksson, L., Greitz, T., Ribbe, T., & Wid??n, L. (1981) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198102000-00027 · Cited by 315
Cited by
Image registration methods: a survey
Zitová, B., & Flusser, J. (2003) · Image and Vision Computing · doi:10.1016/s0262-8856(03)00137-9 · Cited by 6,423
“Different consistency check can be employed when a set of at least two sensed images is registered to the same reference [34,63,87,215].”
BackgroundBuckner, R. L., Snyder, A. Z., Shannon, B. J., LaRossa, G., Sachs, R., Fotenos, A. F., Sheline, Y. I., Klunk, W. E., Mathis, C. A., Morris, J. C., et al. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.2177-05.2005 · Cited by 2,140
“The serially acquired native space data were registered to the initial session data (also in native space) using a nine-parameter affine transform (rigid body translation plus rotation plus cardinal axis stretch) (Freeborough et al., 1996).”
MethodHill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093
Accurate, Robust, and Automated Longitudinal and Cross-Sectional Brain Change Analysis
Smith, S. M., Zhang, Y., Jenkinson, M., Chen, J., Matthews, P. M., Federico, A., & De Stefano, N. (2002) · NeuroImage · doi:10.1006/nimg.2002.1040 · Cited by 2,013
Automated Image Registration: I. General Methods and Intrasubject, Intramodality Validation
Woods, R. P., Grafton, S. T., Holmes, C. J., Cherry, S. R., & Mazziotta, J. C. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199801000-00027 · Cited by 1,707
Self-citationScahill, R. I., Frost, C., Jenkins, R., Whitwell, J. L., Rossor, M. N., & Fox, N. C. (2003) · Archives of Neurology · doi:10.1001/archneur.60.7.989 · Cited by 924
Self-citationGrowth patterns in the developing brain detected by using continuum mechanical tensor maps
Thompson, P. M., Giedd, J. N., Woods, R. P., MacDonald, D., Evans, A. C., & Toga, A. W. (2000) · Nature · doi:10.1038/35004593 · Cited by 850
Self-citationScahill, R. I., Schott, J. M., Stevens, J. M., Rossor, M. N., & Fox, N. C. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.052587399 · Cited by 764
Self-citationMiller, D. H. (2002) · Brain · doi:10.1093/brain/awf177 · Cited by 631
Effects of Aβ immunization (AN1792) on MRI measures of cerebral volume in Alzheimer disease
Fox, N. C., Black, R. S., Gilman, S., Rossor, M. N., Griffith, S. G., Jenkins, L., & Koller, M. (2005) · Neurology · doi:10.1212/01.wnl.0000159743.08996.99 · Cited by 550
Self-citationNormalized Accurate Measurement of Longitudinal Brain Change
Smith, S. M., De Stefano, N., Jenkinson, M., & Matthews, P. M. (2001) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200105000-00022 · Cited by 488
Fox, N. C., Crum, W. R., Scahill, R. I., Stevens, J. M., Janssen, J. C., & Rossor, M. N. (2001) · The Lancet · doi:10.1016/s0140-6736(01)05408-3 · Cited by 455
Self-citationFreeborough, P. A., & Fox, N. C. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.640753 · Cited by 382
Self-citationFox, N. C., Cousens, S., Scahill, R., Harvey, R. J., & Rossor, M. N. (2000) · Archives of Neurology · doi:10.1001/archneur.57.3.339 · Cited by 360
Self-citationFox, N. C., & Freeborough, P. A. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070620 · Cited by 325
Self-citationRusinek, H., De Santi, S., Frid, D., Tsui, W.-H., Tarshish, C. Y., Convit, A., & de Leon, M. J. (2003) · Radiology · doi:10.1148/radiol.2293021299 · Cited by 281
A study of the motion and deformation of the heart due to respiration
McLeish, K., Hill, D. L. G., Atkinson, D., Blackall, J. M., & Razavi, R. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.804427 · Cited by 281
Voxel similarity measures for 3-D serial MR brain image registration
Holden, M., Hill, D. L. G., Denton, E. R. E., Jarosz, J. M., Cox, T. C. S., Rohlfing, T., Goodey, J., & Hawkes, D. J. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.836369 · Cited by 277
The benefit of stereology for quantitative radiology.
Roberts, N., Puddephat, M. J., & McNulty, V (2000) · The British Journal of Radiology · doi:10.1259/bjr.73.871.11089458 · Cited by 248
Voxel Similarity Measures for 3D Serial MR Brain Image Registration
Holden, M., Hill, D. L. G., Denton, E. R. E., Jarosz, J. M., Cox, T. C. S., & Hawkes, D. J. (1999) · Lecture Notes in Computer Science · doi:10.1007/3-540-48714-x_48 · Cited by 246
Harris, G., Andreasen, N. C., Cizadlo, T., Bailey, J. M., Bockholt, H. J., Magnotta, V. A., & Arndt, S. (1999) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199901000-00030 · Cited by 243
Modeling Brain Deformations in Alzheimer Disease by Fluid Registration of Serial 3D MR Images
Freeborough, P. A., & Fox, N. C. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199809000-00031 · Cited by 236
Self-citationBrambati, S. M., Rankin, K. P., Narvid, J., Seeley, W. W., Dean, D., Rosen, H. J., Miller, B. L., Ashburner, J., & Gorno-Tempini, M. L. (2009) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2007.05.014 · Cited by 230
“This technique has proven useful for tracking progression of atrophy in various neurodegenerative diseases (Chan et al., 2001a,b; Fox et al., 2000, 2001, 1999; Fox and Freeborough, 1997; Freeborough et al., 1996; Kipps et al., 2005; Leow et al., 2006; Studholme et al., 2001).”
BackgroundMethodProgressive cerebral atrophy in MS: A serial study using registered, volumetric MRI
Fox, N. C., Jenkins, R., Leary, S. M., Stevenson, V. L., Losseff, N. A., Crum, W. R., Harvey, R. J., Rossor, M. N., Miller, D. H., & Thompson, A. J. (2000) · Neurology · doi:10.1212/wnl.54.4.807 · Cited by 225
Self-citationMRI and CSF studies in the early diagnosis of Alzheimer's disease
De Leon, M. J., DeSanti, S., Zinkowski, R., Mehta, P. D., Pratico, D., Segal, S., Clark, C., Kerkman, D., DeBernardis, J., Li, J., et al. (2004) · Journal of Internal Medicine · doi:10.1111/j.1365-2796.2004.01381.x · Cited by 218
Longitudinal stability of MRI for mapping brain change using tensor-based morphometry
Leow, A. D., Klunder, A. D., Jack, C. R., Toga, A. W., Dale, A. M., Bernstein, M. A., Britson, P. J., Gunter, J. L., Ward, C. P., Whitwell, J. L., et al. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.12.013 · Cited by 214
“, 2001), degenerative rates in Alzheimer’s disease and other dementias (Fox et al., 1997, 1999, 2000, 2001; O’Brien et al., 2001; Freeborough et al., 1996; Freeborough and Fox, 1997; Studholme et al., 2001) as well as tumor growth and multiple sclerosis lesions (Lemieux et al.”
BackgroundSelf-citationBosc, M., Heitz, F., Armspach, J.-P., Namer, I., Gounot, D., & Rumbach, L. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00406-3 · Cited by 210
“Affine (scale and shear) registration gives more accurate results (Freeborough et al., 1996; Lemieux et al., 1998) but is not sufficient to compensate for more complex deformations that may occur.”
BackgroundLong-term retrograde amnesia… the crucial role of the hippocampus
Cipolotti, L., Shallice, T., Chan, D., Fox, N., Scahill, R., Harrison, G., Stevens, J., & Rudge, P. (2001) · Neuropsychologia · doi:10.1016/s0028-3932(00)00103-2 · Cited by 203
“The MIDAS image analysis tools were used for regional segmentation [17].”
MethodSelf-citationImaging and CSF Studies in the Preclinical Diagnosis of Alzheimer's Disease
De LEON, M. J., MOSCONI, L., BLENNOW, K., DeSANTI, S., ZINKOWSKI, R., MEHTA, P. D., PRATICO, D., TSUI, W., LOUIS, L. A. S., SOBANSKA, L., et al. (2007) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1379.012 · Cited by 200
3D pattern of brain atrophy in HIV/AIDS visualized using tensor-based morphometry
Chiang, M.-C., Dutton, R. A., Hayashi, K. M., Lopez, O. L., Aizenstein, H. J., Toga, A. W., Becker, J. T., & Thompson, P. M. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.08.030 · Cited by 178
Mutual information-based rigid and nonrigid registration of ultrasound volumes
Shekhar, R., & Zagrodsky, V. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/42.981230 · Cited by 178
Filippi, M., Horsfield, M. A., Adèr, H. J., Barkhof, F., Bruzzi, P., Evans, A., Frank, J. A., Grossman, R. I., McFarland, H. F., Molyneux, P., et al. (1998) · Annals of Neurology · doi:10.1002/ana.410430414 · Cited by 172
On-line automatic slice positioning for brain MR imaging
van der Kouwe, A. J. W., Benner, T., Fischl, B., Schmitt, F., Salat, D. H., Harder, M., Sorensen, A. G., & Dale, A. M. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.03.035 · Cited by 167
“This has application in tracking lesions in multiple sclerosis (Molyneux et al., 1998), tumors, stroke, and other anatomically apparent neuropathologic symptoms (Freeborough et al., 1996).”
BackgroundAssessing the onset of structural change in familial Alzheimer's disease
Schott, J. M., Fox, N. C., Frost, C., Scahill, R. I., Janssen, J. C., Chan, D., Jenkins, R., & Rossor, M. N. (2003) · Annals of Neurology · doi:10.1002/ana.10424 · Cited by 163
“For each subject, follow-up scans were performed on the same scanner and accurately registered onto baseline images, using a nine degrees of freedom rigid body registration.(13)”
MethodSelf-citationMeasuring atrophy in Alzheimer disease: A serial MRI study over 6 and 12 months
Schott, J. M., Price, S. L., Frost, C., Whitwell, J. L., Rossor, M. N., & Fox, N. C. (2005) · Neurology · doi:10.1212/01.wnl.0000167542.89697.0f · Cited by 162
Self-citationHaemodialysis and cerebral oedema
Walters, R. J. L., Fox, N. C., Crum, W. R., Taube, D., & Thomas, D. J. (2001) · Nephron · doi:10.1159/000045903 · Cited by 87
Self-citationMeasuring disease progression in frontotemporal lobar degeneration: A clinical and MRI study
Gordon, E., Rohrer, J. D., Kim, L. G., Omar, R., Rossor, M. N., Fox, N. C., & Warren, J. D. (2010) · Neurology · doi:10.1212/wnl.0b013e3181d1a879 · Cited by 70
Self-citation
Metadata
- Authors
- Freeborough, P. A., Woods, R. P., & Fox, N. C.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1996-11
- Volume
- 20
- Issue
- 6
- Pages
- 1012-1022
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W1974621282
- Cited by
- 158
- References
- 20
- FWCI
- 13.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.