CoChat

Diagnosis of hypertension using home or ambulatory blood pressure monitoring: comparison with the conventional strategy based on repeated clinic blood pressure measurements

Stergiou, George S., Skeva, Irini I., Baibas, Nikolaos M., Kalkana, Chrysa B., Roussias, Leonidas G., Mountokalakis, Theodore D. · 2000 · Journal of Hypertension
Cited by 128

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To investigate whether measurement of blood pressure at home (HBP) and by ambulatory monitoring (ABP) are reliable alternatives to the traditional strategy for the diagnosis of hypertension based on blood pressure measurement on repeated clinic visits (CBP). DESIGN: Comparison of the diagnosis of hypertension based on HBP (on six workdays) or ABP monitoring (two occasions) with that based on CBP (five visits within 3 months). SETTING: Outpatient hypertension clinic. PARTICIPANTS: We enrolled 133 individuals with a diastolic CBP of 90-115 mmHg on the initial visit. MAIN OUTCOME MEASURES: CBP, HBP and ABP values, and the diagnosis of hypertension. RESULTS: Hypertension was diagnosed in 70, 63 and 56% of individuals using the CBP, ABP and HBP methods respectively (P = 0.04). Agreement in the diagnosis of hypertension between all three methods was found in 59% of individuals. Disagreement between CBP and ABP was found in 27%, between CBP and HBP in 29% and between ABP and HBP in 26% of individuals. The sensitivity, specificity and positive and negative predictive values of ABP to diagnose hypertension correctly were 76, 67, 85 and 53% respectively; for HBP the respective values were 69, 77, 88 and 51%. The same parameters for HBP compared with ABP in the detection of white-coat hypertension were 61, 79, 48 and 86% respectively. CONCLUSIONS: Indiscriminate use of HBP or ABP monitoring in the evaluation of all individuals with high blood pressure will probably result in confusion and therefore should be discouraged. However, in the detection of white-coat hypertension, HBP appears to be useful as a screening test, which, if positive, requires confirmation with ABP monitoring.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004872-200018120-00007

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 128

Metadata

Authors
Stergiou, G. S., Skeva, I. I., Baibas, N. M., Kalkana, C. B., Roussias, L. G., & Mountokalakis, T. D.
Venue
Journal of Hypertension
Published
2000-12
Volume
18
Issue
12
Pages
1745-1751
ISSN
0263-6352 (ISSN-L)
OpenAlex
W1996372541
Cited by
128
References
3
FWCI
4.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnosis of hypertension using home or ambulatory blood pressure monitoring: comparison with the conventional strategy based on repeated clinic blood pressure measurements. https://app.cochat.ai/papers/10.1097/00004872-200018120-00007
The paper
Stergiou, G. S., Skeva, I. I., Baibas, N. M., Kalkana, C. B., Roussias, L. G., & Mountokalakis, T. D. (2000). Diagnosis of hypertension using home or ambulatory blood pressure monitoring: comparison with the conventional strategy based on repeated clinic blood pressure measurements. Journal of Hypertension. https://doi.org/10.1097/00004872-200018120-00007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.