Diagnosis of hypertension using home or ambulatory blood pressure monitoring: comparison with the conventional strategy based on repeated clinic blood pressure measurements
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To investigate whether measurement of blood pressure at home (HBP) and by ambulatory monitoring (ABP) are reliable alternatives to the traditional strategy for the diagnosis of hypertension based on blood pressure measurement on repeated clinic visits (CBP). DESIGN: Comparison of the diagnosis of hypertension based on HBP (on six workdays) or ABP monitoring (two occasions) with that based on CBP (five visits within 3 months). SETTING: Outpatient hypertension clinic. PARTICIPANTS: We enrolled 133 individuals with a diastolic CBP of 90-115 mmHg on the initial visit. MAIN OUTCOME MEASURES: CBP, HBP and ABP values, and the diagnosis of hypertension. RESULTS: Hypertension was diagnosed in 70, 63 and 56% of individuals using the CBP, ABP and HBP methods respectively (P = 0.04). Agreement in the diagnosis of hypertension between all three methods was found in 59% of individuals. Disagreement between CBP and ABP was found in 27%, between CBP and HBP in 29% and between ABP and HBP in 26% of individuals. The sensitivity, specificity and positive and negative predictive values of ABP to diagnose hypertension correctly were 76, 67, 85 and 53% respectively; for HBP the respective values were 69, 77, 88 and 51%. The same parameters for HBP compared with ABP in the detection of white-coat hypertension were 61, 79, 48 and 86% respectively. CONCLUSIONS: Indiscriminate use of HBP or ABP monitoring in the evaluation of all individuals with high blood pressure will probably result in confusion and therefore should be discouraged. However, in the detection of white-coat hypertension, HBP appears to be useful as a screening test, which, if positive, requires confirmation with ABP monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Self-monitoring of blood pressure at home: how many measurements are needed?
Stergiou, G. S., Skeva, I. I., Zourbaki, A. S., & Mountokalakis, T. D. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816060-00002 · Cited by 212
Self-citationHome Self Blood Pressure Measurement in General Practice The SMART Study
Chatellier, G. (1996) · American Journal of Hypertension · doi:10.1016/0895-7061(96)00018-0 · Cited by 116
Thijs, L., Staessen, J. A., Celis, H., Fagard, R., Cort, P. D., de Gaudemaris, R., Enström, I., lmai, Y., Julius, S., Ménard, J., et al. (1999) · Blood Pressure Monitoring · doi:10.1097/00126097-199902000-00004 · Cited by 67
Self-citation
Cited by
Parati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837
Self-citationPickering, T. G., Miller, N. H., Ogedegbe, G., Krakoff, L. R., Artinian, N. T., & Goff, D. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.189010 · Cited by 668
Hodgkinson, J., Mant, J., Martin, U., Guo, B., Hobbs, F. D. R., Deeks, J. J., Heneghan, C., Roberts, N., & McManus, R. J. (2011) · BMJ · doi:10.1136/bmj.d3621 · Cited by 370
Stergiou, G. S., Baibas, N. M., Gantzarou, A. P., Skeva, I. I., Kalkana, C. B., Roussias, L. G., & Mountokalakis, T. D. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(01)02324-x · Cited by 268
Self-citationBlood Pressure Assessment in Adults in Clinical Practice and Clinic-Based Research
Muntner, P., Einhorn, P. T., Cushman, W. C., Whelton, P. K., Bello, N. A., Drawz, P. E., Green, B. B., Jones, D. W., Juraschek, S. P., Margolis, K. L., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.069 · Cited by 199
“ABPM and HBPM should not be considered interchangeable, because there is only moderate agreement between daytime values on ABPM and home BP on HBPM (31,32).”
BackgroundSelf-citationHome Blood Pressure Monitoring in the Diagnosis and Treatment of Hypertension: A Systematic Review
Stergiou, G. S., & Bliziotis, I. A. (2011) · American Journal of Hypertension · doi:10.1038/ajh.2010.194 · Cited by 182
Self-citationHome blood pressure normalcy in children and adolescents: the Arsakeion School study
Stergiou, G. S., Yiannes, N. G., Rarra, V. C., & Panagiotakos, D. B. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e328122d3fc · Cited by 119
Self-citationStergiou, G. S., Nasothimiou, E., Giovas, P., Kapoyiannis, A., & Vazeou, A. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328301c411 · Cited by 114
Self-citationThe optimal home blood pressure monitoring schedule based on the Didima outcome study
Stergiou, G. S., Nasothimiou, E. G., Kalogeropoulos, P. G., Pantazis, N., & Baibas, N. M. (2010) · Journal of Human Hypertension · doi:10.1038/jhh.2009.54 · Cited by 56
Self-citationHome or self blood pressure measurement? What is the correct term?
Stergiou, G. S., Efstathiou, S. P., Alamara, C. V., Mastorantonakis, S. E., & Roussias, L. G. (2003) · Journal of Hypertension · doi:10.1097/00004872-200312000-00013 · Cited by 45
Self-citationRole of ambulatory and home blood pressure recording in clinical practice.
Ghuman, N., Campbell, P., & White, W. B. (2009) · Current Cardiology Reports · doi:10.1007/s11886-009-0060-6 · Cited by 44
Optimal schedule for home blood pressure monitoring based on a clinical approach
Johansson, J. K., Niiranen, T. J., Puukka, P. J., & Jula, A. M. (2010) · Journal of Hypertension · doi:10.1097/hjh.0b013e328332fa5e · Cited by 40
Self blood pressure monitoring: a worthy substitute for ambulatory blood pressure?
McGowan, N., & Padfield, P. L. (2010) · Journal of Human Hypertension · doi:10.1038/jhh.2010.15 · Cited by 31
Karnjanapiboonwong, A., Anothaisintawee, T., Chaikledkaew, U., Dejthevaporn, C., Attia, J., & Thakkinstian, A. (2020) · BMC Cardiovascular Disorders · doi:10.1186/s12872-020-01736-2 · Cited by 27
The optimal schedule for self-home blood pressure monitoring
Stergiou, G. S., & Ntineri, A. (2015) · Journal of Hypertension · doi:10.1097/hjh.0000000000000509 · Cited by 22
Self-citationConstanti, M., Boffa, R., Floyd, C. N., Wierzbicki, A. S., McManus, R. J., & Glover, M. (2021) · Journal of Human Hypertension · doi:10.1038/s41371-020-0357-x · Cited by 21
Home Blood Pressure Monitoring Schedule
Niiranen, T. J., McManus, R. J., Ohkubo, T., & Stergiou, G. S. (2020) · Updates in Hypertension and Cardiovascular Protection · doi:10.1007/978-3-030-23065-4_6 · Cited by 1
Self-citation
Metadata
- Authors
- Stergiou, G. S., Skeva, I. I., Baibas, N. M., Kalkana, C. B., Roussias, L. G., & Mountokalakis, T. D.
- Venue
- Journal of Hypertension
- Published
- 2000-12
- Volume
- 18
- Issue
- 12
- Pages
- 1745-1751
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W1996372541
- Cited by
- 128
- References
- 3
- FWCI
- 4.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.