Self-measured versus ambulatory blood pressure in the diagnosis of hypertension
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: We examined to what extent self-measurement of blood pressure at home (HBP) can be an alternative to ambulatory monitoring (ABP) to diagnose white-coat hypertension. METHODS: In 247 untreated patients, we compared the white-coat effects obtained by HBP and ABP. The thresholds to diagnose hypertension were > or = 140/> or = 90 mmHg for conventional blood pressure (CBP) and > or = 135/> or = 85 mmHg for daytime ABP and HBP. RESULTS: Mean systolic/diastolic CBP, HBP and ABP were 155.4/100.0, 143.1/91.5 and 148.1/95.0 mmHg, respectively. The white-coat effect was 5.0/3.5 mmHg larger on HBP compared with ABP (12.3/8.6 versus 7.2/5.0 mmHg; P < 0.001). The correlation coefficients between the white-coat effects based on HBP and ABP were 0.74 systolic and 0.60 diastolic (P < 0.001). With ABP as a reference, the specificity of HBP to detect white-coat hypertension was 88.6%, and the sensitivity was 68.4%. CONCLUSION: Our findings are in line with the recommendations of the ASH Ad Hoc Panel that recommends HBP for screening while ABP has a better prognostic accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Staessen, J. A. (1999) · JAMA · doi:10.1001/jama.282.6.539 · Cited by 1,592
Self-citationMancia, G., Zanchetti, A., Agebiti-Rosei, E., Benemio, G., De Cesaris, R., Fogari, R., Pessino, A., Porcellati, C., Salvetti, A., & Trimarco, B. (1997) · Circulation · doi:10.1161/01.cir.95.6.1464 · Cited by 596
Self-monitoring of blood pressure at home: how many measurements are needed?
Stergiou, G. S., Skeva, I. I., Zourbaki, A. S., & Mountokalakis, T. D. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816060-00002 · Cited by 212
Cited by
Parati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837
Self-citationPickering, T. G., Miller, N. H., Ogedegbe, G., Krakoff, L. R., Artinian, N. T., & Goff, D. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.189010 · Cited by 668
Rabi, D. M., McBrien, K. A., Sapir-Pichhadze, R., Nakhla, M., Ahmed, S. B., Dumanski, S. M., Butalia, S., Leung, A. A., Harris, K. C., Cloutier, L., et al. (2020) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2020.02.086 · Cited by 583
Siu, A. L., & on behalf of the U.S. Preventive Services Task Force* (2015) · Annals of Internal Medicine · doi:10.7326/m15-2223 · Cited by 491
Fagard, R. H., & Cornelissen, V. A. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e3282ef6185 · Cited by 480
Self-citationPiper, M. A., Evans, C. V., Burda, B. U., Margolis, K. L., O'Connor, E., & Whitlock, E. P. (2015) · Annals of Internal Medicine · doi:10.7326/m14-1539 · Cited by 380
Hodgkinson, J., Mant, J., Martin, U., Guo, B., Hobbs, F. D. R., Deeks, J. J., Heneghan, C., Roberts, N., & McManus, R. J. (2011) · BMJ · doi:10.1136/bmj.d3621 · Cited by 370
Pierdomenico, S. D., & Cuccurullo, F. (2011) · American Journal of Hypertension · doi:10.1038/ajh.2010.203 · Cited by 349
Staessen, J. A. (2004) · JAMA · doi:10.1001/jama.291.8.955 · Cited by 288
Self-citationHome Blood Pressure Measurement
Verberk, W. J., Kroon, A. A., Kessels, A. G. H., & de Leeuw, P. W. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.05.058 · Cited by 212
Home Blood Pressure Monitoring in the Diagnosis and Treatment of Hypertension: A Systematic Review
Stergiou, G. S., & Bliziotis, I. A. (2011) · American Journal of Hypertension · doi:10.1038/ajh.2010.194 · Cited by 182
Stergiou, G. S., Nasothimiou, E., Giovas, P., Kapoyiannis, A., & Vazeou, A. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328301c411 · Cited by 114
Outcome-Driven Thresholds for Increased Home Blood Pressure Variability
Juhanoja, E. P., Niiranen, T. J., Johansson, J. K., Puukka, P. J., Thijs, L., Asayama, K., Langén, V. L., Hozawa, A., Aparicio, L. S., Ohkubo, T., et al. (2017) · Hypertension · doi:10.1161/hypertensionaha.116.08603 · Cited by 83
Self-citationNIIRANEN, T., KANTOLA, I., VESALAINEN, R., JOHANSSON, J., & RUUSKA, M. (2006) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2005.10.017 · Cited by 42
Bello, N. A., Schwartz, J. E., Kronish, I. M., Oparil, S., Anstey, D. E., Wei, Y., Cheung, Y. K. K., Muntner, P., & Shimbo, D. (2018) · Journal of the American Heart Association · doi:10.1161/jaha.118.008658 · Cited by 42
Optimal schedule for home blood pressure monitoring based on a clinical approach
Johansson, J. K., Niiranen, T. J., Puukka, P. J., & Jula, A. M. (2010) · Journal of Hypertension · doi:10.1097/hjh.0b013e328332fa5e · Cited by 40
Verberk, W. J., Kroon, A. A., Kessels, A. G. H., Dirksen, C., Nelemans, P. J., Lenders, J. W. M., Thien, T. A. B. M., van Montfrans, G. A., Smit, A. J., & de Leeuw, P. W. (2003) · Blood Pressure · doi:10.1080/08037050310022405 · Cited by 32
Self blood pressure monitoring: a worthy substitute for ambulatory blood pressure?
McGowan, N., & Padfield, P. L. (2010) · Journal of Human Hypertension · doi:10.1038/jhh.2010.15 · Cited by 31
The optimal schedule for self-home blood pressure monitoring
Stergiou, G. S., & Ntineri, A. (2015) · Journal of Hypertension · doi:10.1097/hjh.0000000000000509 · Cited by 22
“[9] 247 42 no 7 WCH daytime 68 89 33 97 0.”
Constanti, M., Boffa, R., Floyd, C. N., Wierzbicki, A. S., McManus, R. J., & Glover, M. (2021) · Journal of Human Hypertension · doi:10.1038/s41371-020-0357-x · Cited by 21
Home Blood Pressure Monitoring Schedule
Niiranen, T. J., McManus, R. J., Ohkubo, T., & Stergiou, G. S. (2020) · Updates in Hypertension and Cardiovascular Protection · doi:10.1007/978-3-030-23065-4_6 · Cited by 1
Metadata
- Authors
- Hond, E. D., Celis, H., Fagard, R., Keary, L., Leeman, M., O'Brien, E., Vandenhoven, G., & Staessen, J. A.
- Venue
- Journal of Hypertension
- Published
- 2003-04
- Volume
- 21
- Issue
- 4
- Pages
- 717-722
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W1980892512
- Cited by
- 125
- References
- 3
- FWCI
- 7.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.