Combining acoustic and electrical hearing
The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
Objectives/Hypothesis: The concept of combining electrical stimulation for high‐frequency sound with acoustic hearing for low‐frequency information was tested. In addition, whether residual hearing can be preserved when an electrode is placed into the inner ear up to 10 mm and whether place of electrical stimulation influences speech perception were tested. Study Design: A single‐subject clinical trial design was employed. Methods: Six postlingual adults with severe high‐frequency hearing impairment were recruited to participate in the study. A new six‐channel cochlear implant was designed for the clinical trial. The intracochlear electrodes were either 6 or 10 mm in length based on a Nucleus CI‐24 multichannel implant. Monosyllabic word understanding and consonant identification testing in a recorded sound‐only condition were used to assess changes in speech perception. Follow‐up was greater than 12 months. Results: Acoustic hearing was preserved in all six subjects (n = 3,6‐mm electrodes; n = 3,10‐mm electrodes). Preoperative monosyllabic word and sentence scores were unchanged in all subjects following implantation. A 30% to 40% improvement in consonant recognition occurred with the 10‐mm electrode. The subjects with 10‐mm electrodes were able to understand 83% to 90% of the monosyllabic words using the implant plus binaural hearing aids. Scores were more than doubled when compared with preoperative scores with hearing aids only. Conclusion: The human ear has the capability to integrate both acoustic and high‐frequency electrically processed speech information. Placement of a short, 10‐mm electrode does not appear to damage residual low‐frequency inner ear hair cell function, interfere with the micro mechanics of normal cochlear vibration, or decrease residual speech perception. The improvement in speech recognition was due primarily to the increased perception of higher‐frequency consonantal speech cues, and this improvement took several months to become apparent. Such a device can provide a substantial benefit in speech understanding to individuals with severe high‐frequency hearing loss, while still maintaining the benefits of the residual lower‐frequency acoustic hearing. The position of the electrode and the place of frequency information within the cochlea were shown to be important factors in the success of such a device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Speech Recognition with Primarily Temporal Cues
Shannon, R. V., Zeng, F.-G., Kamath, V., Wygonski, J., & Ekelid, M. (1995) · Science · doi:10.1126/science.270.5234.303 · Cited by 3,024
Control Methods Used in a Study of the Vowels
Peterson, G. E., & Barney, H. L. (1952) · The Journal of the Acoustical Society of America · doi:10.1121/1.1906875 · Cited by 2,837
A cochlear frequency-position function for several species—29 years later
Greenwood, D. D. (1990) · The Journal of the Acoustical Society of America · doi:10.1121/1.399052 · Cited by 1,890
Language Development in Profoundly Deaf Children with Cochlear Implants
Svirsky, M. A., Robbins, A. M., Kirk, K. I., Pisoni, D. B., & Miyamoto, R. T. (2000) · Psychological Science · doi:10.1111/1467-9280.00231 · Cited by 647
The Intelligibility of Interrupted Speech
Miller, G. A., & Licklider, J. C. R. (1950) · The Journal of the Acoustical Society of America · doi:10.1121/1.1906584 · Cited by 623
Liberman, M. C., & Dodds, L. W. (1984) · Hearing Research · doi:10.1016/0378-5955(84)90025-x · Cited by 577
Gantz, B. J., Turner, C., Gfeller, K. E., & Lowder, M. W. (2005) · The Laryngoscope · doi:10.1097/01.mlg.0000157695.07536.d2 · Cited by 502
Self-citationDorman, M. F., Loizou, P. C., & Rainey, D. (1997) · The Journal of the Acoustical Society of America · doi:10.1121/1.419603 · Cited by 410
Fu, Q., Shannon, R. V., & Wang, X. (1998) · The Journal of the Acoustical Society of America · doi:10.1121/1.423941 · Cited by 388
Fishman, K. E., Shannon, R. V., & Slattery, W. H. (1997) · Journal of Speech, Language, and Hearing Research · doi:10.1044/jslhr.4005.1201 · Cited by 380
Music Perception with Temporal Cues in Acoustic and Electric Hearing
Kong, Y.-Y., Cruz, R., Jones, J. A., & Zeng, F.-G. (2004) · Ear and Hearing · doi:10.1097/01.aud.0000120365.97792.2f · Cited by 377
Speech recognition in noise for cochlear implant listeners: Benefits of residual acoustic hearing
Turner, C. W., Gantz, B. J., Vidal, C., Behrens, A., & Henry, B. A. (2004) · The Journal of the Acoustical Society of America · doi:10.1121/1.1687425 · Cited by 363
Self-citationSpeech and melody recognition in binaurally combined acoustic and electric hearing
Kong, Y.-Y., Stickney, G. S., & Zeng, F.-G. (2005) · The Journal of the Acoustical Society of America · doi:10.1121/1.1857526 · Cited by 351
Cochlear implant speech recognition with speech maskers
Stickney, G. S., Zeng, F.-G., Litovsky, R., & Assmann, P. (2004) · The Journal of the Acoustical Society of America · doi:10.1121/1.1772399 · Cited by 340
Understanding speech in modulated interference: Cochlear implant users and normal-hearing listeners
Nelson, P. B., Jin, S.-H., Carney, A. E., & Nelson, D. A. (2003) · The Journal of the Acoustical Society of America · doi:10.1121/1.1531983 · Cited by 318
Duquesnoy, A. J. (1983) · The Journal of the Acoustical Society of America · doi:10.1121/1.389859 · Cited by 282
Hearing preservation in cochlear implantation for electric acoustic stimulation
Gstoettner, W., Kiefer, J., Baumgartner, W.-D., Pok, S., Peters, S., & Adunka, O. (2004) · Acta Oto-Laryngologica · doi:10.1080/00016480410016432 · Cited by 277
Rubinstein, J. T., Wilson, B. S., Finley, C. C., & Abbas, P. J. (1999) · Hearing Research · doi:10.1016/s0378-5955(98)00185-3 · Cited by 276
Physiological properties of the electrically stimulated auditory nerve. II. Single fiber recordings
van den Honert, C., & Stypulkowski, P. H. (1984) · Hearing Research · doi:10.1016/0378-5955(84)90052-2 · Cited by 275
Dorman, M. F., Gifford, R. H., Spahr, A. J., & McKarns, S. A. (2008) · Audiology and Neurotology · doi:10.1159/000111782 · Cited by 275
Importance of tonal envelope cues in Chinese speech recognition
Fu, Q.-J., Zeng, F.-G., Shannon, R. V., & Soli, S. D. (1998) · The Journal of the Acoustical Society of America · doi:10.1121/1.423251 · Cited by 258
Tomblin, J. B., Spencer, L., Flock, S., Tyler, R., & Gantz, B. (1999) · Journal of Speech, Language, and Hearing Research · doi:10.1044/jslhr.4202.497 · Cited by 254
Self-citationXu, J., Shepherd, R. K., Millard, R. E., & Clark, G. M. (1997) · Hearing Research · doi:10.1016/s0378-5955(96)00193-1 · Cited by 242
Leake, P. A., Hradek, G. T., Rebscher, S. J., & Snyder, R. L. (1991) · Hearing Research · doi:10.1016/0378-5955(91)90120-x · Cited by 206
Speech recognition with altered spectral distribution of envelope cues
Shannon, R. V., Zeng, F.-G., & Wygonski, J. (1998) · The Journal of the Acoustical Society of America · doi:10.1121/1.423774 · Cited by 193
Features of stimulation affecting tonal-speech perception: Implications for cochlear prostheses
Xu, L., Tsai, Y., & Pfingst, B. E. (2002) · The Journal of the Acoustical Society of America · doi:10.1121/1.1487843 · Cited by 191
Peng, S., Tomblin, J. B., & Turner, C. W. (2008) · Ear and Hearing · doi:10.1097/aud.0b013e318168d94d · Cited by 181
Self-citationZhang, T., Dorman, M. F., & Spahr, A. J. (2010) · Ear & Hearing · doi:10.1097/aud.0b013e3181b7190c · Cited by 177
Conservation of Residual Acoustic Hearing After Cochlear Implantation
Balkany, T. J., Connell, S. S., Hodges, A. V., Payne, S. L., Telischi, F. F., Eshraghi, A. A., Angeli, S. I., Germani, R., Messiah, S., & Arheart, K. L. (2006) · Otology & Neurotology · doi:10.1097/01.mao.0000244355.34577.85 · Cited by 176
Gantz, B. J., Turner, C., & Gfeller, K. E. (2006) · Audiology and Neurotology · doi:10.1159/000095616 · Cited by 170
Self-citationChanges in Pitch with a Cochlear Implant Over Time
Reiss, L. A. J., Turner, C. W., Erenberg, S. R., & Gantz, B. J. (2007) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s10162-007-0077-8 · Cited by 169
Self-citationSpeech recognition with altered spectral distribution of envelope cues
Shannon, R. V., Zeng, F.-G., & Wygonski, J. (1996) · The Journal of the Acoustical Society of America · doi:10.1121/1.417043 · Cited by 169
Combining acoustic and electric stimulation in the service of speech recognition
Dorman, M. F., & Gifford, R. H. (2010) · International Journal of Audiology · doi:10.3109/14992027.2010.509113 · Cited by 162
Snyder, R. L., Bierer, J. A., & Middlebrooks, J. C. (2004) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s10162-004-4026-5 · Cited by 154
Shepherd, R. K., Clark, G. M., & Black, R. C. (1983) · Acta Oto-Laryngologica · doi:10.3109/00016488309105589 · Cited by 146
The perception of Cantonese lexical tones by early-deafened cochlear implantees
Ciocca, V., Francis, A. L., Aisha, R., & Wong, L. L. N. (2002) · The Journal of the Acoustical Society of America · doi:10.1121/1.1471897 · Cited by 142
Neural and mechanical responses to electric stimulation of the cat's inner ear.
Moxon, E. C. (1971) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 116
Single-Fiber Recording: In Vivo and In Vitro Preparations
Schäfers, M., & Cain, D. (2004) · Humana Press eBooks · doi:10.1385/1-59259-770-x:035 · Cited by 116
Estimation of Volume Referent Bone Turnover in the Otic Capsule after Sequential Point Labeling
Frisch, T., Overgaard, S., Sørensen, M. S., & Bretlau, P. (2000) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348940010900106 · Cited by 109
Ni, D.-F., Shepherd, R. K., Seldon, H. L., Xu, S.-A., Clark, G. M., & Millard, R. E. (1992) · Hearing Research · doi:10.1016/0378-5955(92)90203-y · Cited by 104
Unintelligible Low-Frequency Sound Enhances Simulated Cochlear-Implant Speech Recognition in Noise
Chang, J. E., Bai, J. Y., & Zeng, F. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.883793 · Cited by 104
Preservation of Basal Inner Ear Structures in Cochlear Implantation
Adunka, O. F., Gstoettner, W., Hambek, M., et al. (2004) · ORL · doi:10.1159/000081887 · Cited by 100
The Effects of Bilateral Electric and Bimodal Electric—Acoustic Stimulation on Language Development
Nittrouer, S., & Chapman, C. (2009) · Trends in Amplification · doi:10.1177/1084713809346160 · Cited by 94
Prediction of uvulopalatopharyngoplasty response using cephalometric radiographs
Woodson, B. T., & Conley, S. F. (1997) · American Journal of Otolaryngology · doi:10.1016/s0196-0709(97)90079-x · Cited by 89
Achieving Electric-Acoustic Benefit with a Modulated Tone
Brown, C. A., & Bacon, S. P. (2009) · Ear and Hearing · doi:10.1097/aud.0b013e3181ab2b87 · Cited by 83
Araki, S., Kawano, A., Seldon, H. L., Shepherd, R. K., Funasaka, S., & Clark, G. M. (1998) · The Laryngoscope · doi:10.1097/00005537-199805000-00012 · Cited by 62
Cited by
Cochlear implants: A remarkable past and a brilliant future
Wilson, B. S., & Dorman, M. F. (2008) · Hearing Research · doi:10.1016/j.heares.2008.06.005 · Cited by 868
Gantz, B. J., Turner, C., Gfeller, K. E., & Lowder, M. W. (2005) · The Laryngoscope · doi:10.1097/01.mlg.0000157695.07536.d2 · Cited by 502
Self-citationZeng, F.-G. (2004) · Trends in Amplification · doi:10.1177/108471380400800102 · Cited by 401
Cochlear implants: Current designs and future possibilities
Wilson, B. S. (2008) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2007.10.0173 · Cited by 396
Speech recognition in noise for cochlear implant listeners: Benefits of residual acoustic hearing
Turner, C. W., Gantz, B. J., Vidal, C., Behrens, A., & Henry, B. A. (2004) · The Journal of the Acoustical Society of America · doi:10.1121/1.1687425 · Cited by 363
Self-citation
Metadata
- Authors
- Gantz, B. J., & Turner, C. W.
- Venue
- The Laryngoscope
- Publisher
- Wiley
- Published
- 2003-10
- Volume
- 113
- Issue
- 10
- Pages
- 1726-1730
- ISSN
- 0023-852X (ISSN-L)
- 1531-4995
- OpenAlex
- W1968494648
- Cited by
- 377
- References
- 46
- FWCI
- 7.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.