Combining acoustic and electrical hearing
The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
Objectives/Hypothesis: The concept of combining electrical stimulation for high‐frequency sound with acoustic hearing for low‐frequency information was tested. In addition, whether residual hearing can be preserved when an electrode is placed into the inner ear up to 10 mm and whether place of electrical stimulation influences speech perception were tested. Study Design: A single‐subject clinical trial design was employed. Methods: Six postlingual adults with severe high‐frequency hearing impairment were recruited to participate in the study. A new six‐channel cochlear implant was designed for the clinical trial. The intracochlear electrodes were either 6 or 10 mm in length based on a Nucleus CI‐24 multichannel implant. Monosyllabic word understanding and consonant identification testing in a recorded sound‐only condition were used to assess changes in speech perception. Follow‐up was greater than 12 months. Results: Acoustic hearing was preserved in all six subjects (n = 3,6‐mm electrodes; n = 3,10‐mm electrodes). Preoperative monosyllabic word and sentence scores were unchanged in all subjects following implantation. A 30% to 40% improvement in consonant recognition occurred with the 10‐mm electrode. The subjects with 10‐mm electrodes were able to understand 83% to 90% of the monosyllabic words using the implant plus binaural hearing aids. Scores were more than doubled when compared with preoperative scores with hearing aids only. Conclusion: The human ear has the capability to integrate both acoustic and high‐frequency electrically processed speech information. Placement of a short, 10‐mm electrode does not appear to damage residual low‐frequency inner ear hair cell function, interfere with the micro mechanics of normal cochlear vibration, or decrease residual speech perception. The improvement in speech recognition was due primarily to the increased perception of higher‐frequency consonantal speech cues, and this improvement took several months to become apparent. Such a device can provide a substantial benefit in speech understanding to individuals with severe high‐frequency hearing loss, while still maintaining the benefits of the residual lower‐frequency acoustic hearing. The position of the electrode and the place of frequency information within the cochlea were shown to be important factors in the success of such a device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Speech Recognition with Primarily Temporal Cues
Shannon, R. V., Zeng, F.-G., Kamath, V., Wygonski, J., & Ekelid, M. (1995) · Science · doi:10.1126/science.270.5234.303 · Cited by 3,024
Control Methods Used in a Study of the Vowels
Peterson, G. E., & Barney, H. L. (1952) · The Journal of the Acoustical Society of America · doi:10.1121/1.1906875 · Cited by 2,837
A cochlear frequency-position function for several species—29 years later
Greenwood, D. D. (1990) · The Journal of the Acoustical Society of America · doi:10.1121/1.399052 · Cited by 1,890
Language Development in Profoundly Deaf Children with Cochlear Implants
Svirsky, M. A., Robbins, A. M., Kirk, K. I., Pisoni, D. B., & Miyamoto, R. T. (2000) · Psychological Science · doi:10.1111/1467-9280.00231 · Cited by 647
The Intelligibility of Interrupted Speech
Miller, G. A., & Licklider, J. C. R. (1950) · The Journal of the Acoustical Society of America · doi:10.1121/1.1906584 · Cited by 623
Liberman, M. C., & Dodds, L. W. (1984) · Hearing Research · doi:10.1016/0378-5955(84)90025-x · Cited by 577
Gantz, B. J., Turner, C., Gfeller, K. E., & Lowder, M. W. (2005) · The Laryngoscope · doi:10.1097/01.mlg.0000157695.07536.d2 · Cited by 502
Self-citationDorman, M. F., Loizou, P. C., & Rainey, D. (1997) · The Journal of the Acoustical Society of America · doi:10.1121/1.419603 · Cited by 410
Fu, Q., Shannon, R. V., & Wang, X. (1998) · The Journal of the Acoustical Society of America · doi:10.1121/1.423941 · Cited by 388
Fishman, K. E., Shannon, R. V., & Slattery, W. H. (1997) · Journal of Speech, Language, and Hearing Research · doi:10.1044/jslhr.4005.1201 · Cited by 380
Cited by
Cochlear implants: A remarkable past and a brilliant future
Wilson, B. S., & Dorman, M. F. (2008) · Hearing Research · doi:10.1016/j.heares.2008.06.005 · Cited by 868
Gantz, B. J., Turner, C., Gfeller, K. E., & Lowder, M. W. (2005) · The Laryngoscope · doi:10.1097/01.mlg.0000157695.07536.d2 · Cited by 502
Self-citationZeng, F.-G. (2004) · Trends in Amplification · doi:10.1177/108471380400800102 · Cited by 401
Cochlear implants: Current designs and future possibilities
Wilson, B. S. (2008) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2007.10.0173 · Cited by 396
Speech recognition in noise for cochlear implant listeners: Benefits of residual acoustic hearing
Turner, C. W., Gantz, B. J., Vidal, C., Behrens, A., & Henry, B. A. (2004) · The Journal of the Acoustical Society of America · doi:10.1121/1.1687425 · Cited by 363
Self-citationSpeech and melody recognition in binaurally combined acoustic and electric hearing
Kong, Y.-Y., Stickney, G. S., & Zeng, F.-G. (2005) · The Journal of the Acoustical Society of America · doi:10.1121/1.1857526 · Cited by 351
Quality Control After Insertion of the Nucleus Contour and Contour Advance Electrode in Adults
Aschendorff, A., Kromeier, J., Klenzner, T., & Laszig, R. (2007) · Ear & Hearing · doi:10.1097/aud.0b013e318031542e · Cited by 310
The cochlear implant: historical aspects and future prospects
Eshraghi, A. A., Nazarian, R., Telischi, F. F., Rajguru, S. M., Truy, E., & Gupta, C. (2012) · The Anatomical Record · doi:10.1002/ar.22580 · Cited by 285
Cochlear Implant – State of the Art
Lenarz, T. (2017) · Laryngo-Rhino-Otologie · doi:10.1055/s-0043-101812 · Cited by 283
In Vivo Estimates of the Position of Advanced Bionics Electrode Arrays in the Human Cochlea
Skinner, M. W., Holden, T. A., Whiting, B. R., Voie, A. H., Brunsden, B., Neely, J. G., Saxon, E. A., Hullar, T. E., & Finley, C. C. (2007) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/000348940711600401 · Cited by 243
Multichannel Cochlear Implants: Relation of Histopathology to Performance
Fayad, J. N., & Linthicum, F. H. (2006) · The Laryngoscope · doi:10.1097/01.mlg.0000227176.09500.28 · Cited by 222
Gantz, B. J., Turner, C., & Gfeller, K. E. (2006) · Audiology and Neurotology · doi:10.1159/000095616 · Cited by 170
Self-citationWang, N. Y.-H., Wang, H.-L. S., Wang, T.-W., Fu, S.-W., Lu, X., Wang, H.-M., & Tsao, Y. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.3042655 · Cited by 24
“Although the benefits of EAS have been documented [18], [19], there is room for improvement in the performance of EAS in noisy environments.”
Background
Metadata
- Authors
- Gantz, B. J., & Turner, C. W.
- Venue
- The Laryngoscope
- Publisher
- Wiley
- Published
- 2003-10
- Volume
- 113
- Issue
- 10
- Pages
- 1726-1730
- ISSN
- 0023-852X (ISSN-L)
- 1531-4995
- OpenAlex
- W1968494648
- Cited by
- 377
- References
- 46
- FWCI
- 7.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.