Effects of hydration changes on bioelectrical impedance in endurance trained individuals
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
PURPOSE: The purpose of this study was to determine how differences in hydration states and ion content of hydrating fluids affected bioelectrical impedance (BI) and hydrostatic weighing (HW) measurements. METHODS: Fifteen athletic subjects aged 19-56 yr were recruited. Relative body fat (%), fat-weight (FW), and fat-free weight (FFW) were assessed using BI and HW under normal conditions (N), hypohydration (HPO), rehydration (RHY), and superhydration (SHY) states. During the RHY and SHY trial periods, subjects were hydrated with either distilled water or an electrolyte solution (ELS). HPO and SHY levels were set at 3% of each person's normally hydrated body weight. RESULTS: Comparison between the distilled water and the ELS trials indicated that hydration solution had no effect on BI or HW. Thus, the results presented are the trial means of both hydration solutions combined. Both BI and HW were shown to be highly test-retest reliable (r-values: 0.96 and 0.99, respectively). The effects of exercise induced HPO followed by RHY on body composition values indicated that HW was very stable across measurement periods while BI was not. From N to the HPO state, BI %BF declined from 14.4 +/- 5.3% to 12.3 +/- 5.3%, respectively. After RHY, BIA %BF increased to 15.5 +/- 5.8%. Similar findings occurred when subjects were superhydrated (N-BI = 13.2 +/- 5.3%; SHY-BI = 15.4 +/- 5.6%). With a comparison of the intercepts and slopes of HW and BIA for the N and SHY states, it was clear hydration status significantly affected the intercepts (HW: 0.37 vs. BI: 1.85) and not the slopes (HW: 1.00 vs BI: 0.99). As a result, a majority of all fluid changes were interpreted as FW by BI. During HPO, 82% of the weight loss was considered FW while during RHY or SHY, 128% and 85% of the water weight regain/gain was considered FW. CONCLUSION: These results indicate that BI is not a valid technique in athletes, especially when wanting to determine body composition effects of training/detraining. This study indicates that even small fluid changes such as those that occur with endurance training may be interpreted incorrectly as changes in an athlete's body fat content.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896
Validation of tetrapolar bioelectrical impedance method to assess human body composition
Lukaski, H. C., Bolonchuk, W. W., Hall, C. B., & Siders, W. A. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.4.1327 · Cited by 1,370
Lean body mass estimation by bioelectrical impedance analysis: a four-site cross-validation study
Segal, K., Van Loan, M., Fitzgerald, P., Hodgdon, A., & Van Itallie, T. (1988) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/47.1.7 · Cited by 881
Body composition in Pima Indians: validation of bioelectrical resistance
Rising, R., Swinburn, B., Larson, K., & Ravussin, E. (1991) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/53.3.594 · Cited by 77
Cited by
Shirreffs, S. M. (2003) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1601895 · Cited by 300
Moon, J. R. (2013) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2012.165 · Cited by 237
Heydenreich, J., Kayser, B., Schutz, Y., & Melzer, K. (2017) · Sports Medicine - Open · doi:10.1186/s40798-017-0076-1 · Cited by 177
Esco, M. R., Snarr, R. L., Leatherwood, M. D., Chamberlain, N. A., Redding, M. L., Flatt, A. A., Moon, J. R., & Williford, H. N. (2015) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000000732 · Cited by 122
“Therefore, the FFM and BF% errors associated with DXA may be similar to the errors observed from the InBody 720 device when compared with criterion multicompartment model that accounts for body water.”
BackgroundFood and macronutrient intake of elite Kenyan distance runners
Onywera, V. O., Kiplamai, F. K., Tuitoek, P. J., Boit, M. K., & Pitsiladis, Y. P. (2004) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.14.6.709 · Cited by 111
“In addition, this method cannot distinguish between fat loss and fluid loss and data obtained can be compromised if subjects are in a state of dehydration (18).”
Method
Metadata
- Authors
- SAUNDERS, M. J., BLEVINS, J. E., & BROEDER, C. E.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1998-06
- Volume
- 30
- Issue
- 6
- Pages
- 885-892
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2017872961
- Cited by
- 60
- References
- 4
- FWCI
- 0.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of hydration changes on bioelectrical impedance in endurance trained individuals. https://app.cochat.ai/papers/10.1097/00005768-199806000-00017
- The paper
- SAUNDERS, M. J., BLEVINS, J. E., & BROEDER, C. E. (1998). Effects of hydration changes on bioelectrical impedance in endurance trained individuals. Medicine & Science in Sports & Exercise. https://doi.org/10.1097/00005768-199806000-00017
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.