Clinical Experience with 118 Brain Tissue Oxygen Partial Pressure Catheter Probes
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: We assessed the technical and diagnostic reliability of partial pressure of oxygen (PO2) of brain tissue (P(ti)O2) monitoring. The monitoring system and the catheter probes were tested in vitro, and clinical experiences obtained with 118 brain P(ti)O2 catheter probes, used in 101 patients, are reported. METHODS: The polarographic (LICOX; Medical Systems Corp., Greenvale, NY) P(ti)O2 catheter probe lies 22 to 27 mm below the dura level; its PO2-sensitive surface is 7.1 mm2. For 10 patients, the adaptation time (with initially unreliable signals after insertion) was determined. For 27 patients, the probe was removed in a stepwise fashion (three increments of 5 mm) and the heterogeneity of brain P(ti)O2 levels was investigated. After removal of the catheter probes, their PO2 and zero display error values were determined and compared with probe performance data obtained in vitro with unused PO2 catheter probes. RESULTS: Small iatrogenic hematomas were observed for two patients (1.7%). No infection occurred after 6.7 +/- 3.9 days (mean +/- standard deviation) of monitoring. The technical complication (dislocation or defect) rate was 13.6%. The mean adaptation time was 79.0 +/- 51.7 min. A flow chart is presented, which helps to rule out artifacts. The mean P(ti)O2 measured at 22 to 27 mm below the dura was 23.8 +/- 8.1 mm Hg, at 17 to 22 mm was 25.7 +/- 8.3 mm Hg, at 12 to 17 mm was 33.0 +/- 13.3 mm Hg (P < 0.01, compared with the initial value), and at 7 to 12 mm was 33.3 +/- 13.3 mm Hg (P < 0.01). Recent catheter probe versions exhibited a PO2 display error of -1.2 +/- 5.1% (mean +/- standard deviation, n = 38) and a mean zero display error of 1.1 +/- 0.9 mm Hg (n = 34). The greatest PO2 display errors were measured during the first 4 days of continuous monitoring. In the in vitro test (of 12 unused catheter probes), the maximal probe display error was 1.07 +/- 2.14%, tested at temperatures between 22 degrees C and 37 degrees C and tested at oxygen pressures of 0, 44, and 150 mm Hg. In vitro, the zero display error was -0.21 +/- 0.25 mm Hg. CONCLUSION: Brain P(ti)O2 monitoring, reflecting an area 17 to 27 mm below the dura, is a safe and reliable technique for monitoring cerebral oxygenation. Excluding the first 1 hour after insertion, data are reliable, with almost 100% good data quality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Siesjö, B. K. (1978) · Medical Entomology and Zoology · Cited by 1,437
Frackowiak, R. S. J., Lenzi, G.-L., Jones, T., & Heather, J. D. (1980) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198012000-00001 · Cited by 1,242
Bouma, G. J., Muizelaar, J. P., Choi, S. C., Newlon, P. G., & Young, H. F. (1991) · Journal of Neurosurgery · doi:10.3171/jns.1991.75.5.0685 · Cited by 717
Narayan, R. K., Kishore, P. R. S., Becker, D. P., Ward, J. D., Enas, G. G., Greenberg, R. P., Da Silva, A. D., Lipper, M. H., Choi, S. C., Mayhall, C. G., et al. (1982) · Journal of Neurosurgery · doi:10.3171/jns.1982.56.5.0650 · Cited by 591
Bouma, G. J., Muizelaar, J. P., Stringer, W. A., Choi, S. C., Fatouros, P., & Young, H. F. (1992) · Journal of Neurosurgery · doi:10.3171/jns.1992.77.3.0360 · Cited by 549
Smith, D. S. (1993) · Journal of Neurosurgical Anesthesiology · doi:10.1097/00008506-199301000-00013 · Cited by 467
Jugular venous desaturation and outcome after head injury.
Gopinath, S. P., Robertson, C. S., Contant, C. F., Hayes, C., Feldman, Z., Narayan, R. K., & Grossman, R. G. (1994) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.57.6.717 · Cited by 442
Continuous monitoring of jugular venous oxygen saturation in head-injured patients
Sheinberg, M., Kanter, M. J., Robertson, C. S., Contant, C. F., Narayan, R. K., & Grossman, R. G. (1992) · Journal of Neurosurgery · doi:10.3171/jns.1992.76.2.0212 · Cited by 422
Acute regional cerebral blood flow changes caused by severe head injuries
Marion, D. W., Darby, J., & Yonas, H. (1991) · Journal of Neurosurgery · doi:10.3171/jns.1991.74.3.0407 · Cited by 410
Kiening, K. L., Unterberg, A. W., Bardt, T. F., Schneider, G.-H., & Lanksch, W. R. (1996) · Journal of Neurosurgery · doi:10.3171/jns.1996.85.5.0751 · Cited by 408
Continuous Monitoring of Partial Pressure of Brain Tissue Oxygen in Patients with Severe Head Injury
van Santbrink, H., Maas, A. I. R., & Avezaat, C. J. J. (1996) · Neurosurgery · doi:10.1097/00006123-199601000-00007 · Cited by 389
Oxygen in mammalian tissue: methods of measurement and affinities of various reactions
Vanderkooi, J. M., Erecinska, M., & Silver, I. A. (1991) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1991.260.6.c1131 · Cited by 277
Brain Tissue Oxygen, Carbon Dioxide, and pH in Neurosurgical Patients at Risk for Ischemia
Hoffman, W. E., Charbel, F. T., & Edelman, G. (1996) · Anesthesia & Analgesia · doi:10.1097/00000539-199603000-00027 · Cited by 171
Studies of Tissue PO2 in Normal and Pathological Human Brain Cortex
Meixensberger, J., Dings, J. T. A., Kuhnigk, H., & Roosen, K. (1993) · Springer eBooks · doi:10.1007/978-3-7091-9302-0_10 · Cited by 140
Self-citationEvaluation of a fiberoptic intracranial pressure monitor
Crutchfield, J. S., Narayan, R. K., ROBERTSON, C. S., & Michael, L. H. (1990) · Journal of neurosurgery · doi:10.3171/jns.1990.72.3.0482 · Cited by 124
Zauner, A., DOPPENBERG, E. M. R., Woodward, J., Allen, C., Jebraili, S., Young, H. F., & Bullock, R. M. (1997) · Neurological Research · doi:10.1080/01616412.1997.11740812 · Cited by 118
Baumgärtl, H., & Lübbers, D. W. (1983) · Springer eBooks · doi:10.1007/978-3-642-81863-9_4 · Cited by 108
Regulation of local tissuePo 2of the brain cortex at different arterial O2 pressures
Leniger-Follert, E., L�bbers, D. W., & Wrabetz, W. (1975) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00581279 · Cited by 105
Dings, J. T. A., Meixensberger, J., Amschler, J., Hamelbeck, B., & Roosen, K. (1996) · Acta Neurochirurgica · doi:10.1007/bf01420305 · Cited by 93
Self-citationBrain tissuepO2-monitoring: Catheterstability and complications
Dings, J. T. A., Meixensberger, J., & Roosen, K. (1997) · Neurological Research · doi:10.1080/01616412.1997.11740806 · Cited by 57
Self-citationDirect Intraoperative Measurement of Human Brain Temperature
Stone, J. G., Goodman, R. R., Baker, K. Z., Baker, C. J., & Solomon, R. A. (1997) · Neurosurgery · doi:10.1097/00006123-199707000-00007 · Cited by 56
Metzger, H., & Heuber, S. (1977) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00581695 · Cited by 45
The oxygen tension field within a discrete volume of cerebral cortex
Smith, R. H., Guilbeau, E. J., & Reneau, D. D. (1977) · Microvascular Research · doi:10.1016/0026-2862(77)90088-7 · Cited by 44
Seyde, W. C., & Longnecker, D. E. (1986) · Anesthesiology · doi:10.1097/00000542-198604000-00011 · Cited by 37
Oxygen supply to tissue in normoxia and in oxygen deficiency
KESSLER, M. (1974) · Microvascular Research · doi:10.1016/s0026-2862(74)80004-x · Cited by 31
Prospective study of zero drift in fiberoptic pressure monitors used in clinical practice
Bavetta, S., Norris, J. S., Wyatt, M., Sutcliffe, J., & Hamlyn, P. J. (1997) · Journal of neurosurgery · doi:10.3171/jns.1997.86.6.0927 · Cited by 28
Eintrei, C., & Lund, N. (1986) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1986.tb02395.x · Cited by 22
Tissue pO2 of Normal and Pathological Human Brain Cortex
Dings, J. T. A., Meixensberger, J., Kuhnigk, H., et al. (1994) · Advances in neurosurgery · doi:10.1007/978-3-642-78801-7_32 · Cited by 2
Self-citation
Cited by
The role of hypoxia in cancer progression, angiogenesis, metastasis, and resistance to therapy
Muz, B., de la Puente, P., Azab, F., & Azab, A. K. (2015) · Hypoxia · doi:10.2147/hp.s93413 · Cited by 2,066
Oxygen in Stem Cell Biology: A Critical Component of the Stem Cell Niche
Mohyeldin, A., Garzón-Muvdi, T., & Quiñones-Hinojosa, A. (2010) · Cell Stem Cell · doi:10.1016/j.stem.2010.07.007 · Cited by 1,535
Why is the partial oxygen pressure of human tissues a crucial parameter? Small molecules and hypoxia
Carreau, A., Hafny‐Rahbi, B. E., Matejuk, A., Grillon, C., & Kieda, C. (2011) · Journal of Cellular and Molecular Medicine · doi:10.1111/j.1582-4934.2011.01258.x · Cited by 1,246
“[56] in 1998 undertook complete monitoring of brain tissue pO2 as a function of the depth underneath the dura level.”
BackgroundHall, C. N., Klein-Flugge, M. C., Howarth, C., & Attwell, D. (2012) · Journal of Neuroscience · doi:10.1523/jneurosci.0026-12.2012 · Cited by 451
Stiefel, M. F., Spiotta, A., Gracias, V. H., Garuffe, A. M., Guillamondegui, O., Maloney-Wilensky, E., Bloom, S., Grady, M. S., & LeRoux, P. D. (2005) · Journal of Neurosurgery · doi:10.3171/jns.2005.103.5.0805 · Cited by 429
Metadata
- Authors
- Dings, J., Meixensberger, J., Jäger, A., & Roosen, K.
- Venue
- Neurosurgery
- Published
- 1998-11
- Volume
- 43
- Issue
- 5
- Pages
- 1082-1094
- ISSN
- 0148-396X (ISSN-L)
- 1524-4040
- OpenAlex
- W2077067643
- Cited by
- 323
- References
- 28
- FWCI
- 4.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.