Clinical Experience with 118 Brain Tissue Oxygen Partial Pressure Catheter Probes
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: We assessed the technical and diagnostic reliability of partial pressure of oxygen (PO2) of brain tissue (P(ti)O2) monitoring. The monitoring system and the catheter probes were tested in vitro, and clinical experiences obtained with 118 brain P(ti)O2 catheter probes, used in 101 patients, are reported. METHODS: The polarographic (LICOX; Medical Systems Corp., Greenvale, NY) P(ti)O2 catheter probe lies 22 to 27 mm below the dura level; its PO2-sensitive surface is 7.1 mm2. For 10 patients, the adaptation time (with initially unreliable signals after insertion) was determined. For 27 patients, the probe was removed in a stepwise fashion (three increments of 5 mm) and the heterogeneity of brain P(ti)O2 levels was investigated. After removal of the catheter probes, their PO2 and zero display error values were determined and compared with probe performance data obtained in vitro with unused PO2 catheter probes. RESULTS: Small iatrogenic hematomas were observed for two patients (1.7%). No infection occurred after 6.7 +/- 3.9 days (mean +/- standard deviation) of monitoring. The technical complication (dislocation or defect) rate was 13.6%. The mean adaptation time was 79.0 +/- 51.7 min. A flow chart is presented, which helps to rule out artifacts. The mean P(ti)O2 measured at 22 to 27 mm below the dura was 23.8 +/- 8.1 mm Hg, at 17 to 22 mm was 25.7 +/- 8.3 mm Hg, at 12 to 17 mm was 33.0 +/- 13.3 mm Hg (P < 0.01, compared with the initial value), and at 7 to 12 mm was 33.3 +/- 13.3 mm Hg (P < 0.01). Recent catheter probe versions exhibited a PO2 display error of -1.2 +/- 5.1% (mean +/- standard deviation, n = 38) and a mean zero display error of 1.1 +/- 0.9 mm Hg (n = 34). The greatest PO2 display errors were measured during the first 4 days of continuous monitoring. In the in vitro test (of 12 unused catheter probes), the maximal probe display error was 1.07 +/- 2.14%, tested at temperatures between 22 degrees C and 37 degrees C and tested at oxygen pressures of 0, 44, and 150 mm Hg. In vitro, the zero display error was -0.21 +/- 0.25 mm Hg. CONCLUSION: Brain P(ti)O2 monitoring, reflecting an area 17 to 27 mm below the dura, is a safe and reliable technique for monitoring cerebral oxygenation. Excluding the first 1 hour after insertion, data are reliable, with almost 100% good data quality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Siesjö, B. K. (1978) · Medical Entomology and Zoology · Cited by 1,437
Frackowiak, R. S. J., Lenzi, G.-L., Jones, T., & Heather, J. D. (1980) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198012000-00001 · Cited by 1,242
Bouma, G. J., Muizelaar, J. P., Choi, S. C., Newlon, P. G., & Young, H. F. (1991) · Journal of Neurosurgery · doi:10.3171/jns.1991.75.5.0685 · Cited by 717
Narayan, R. K., Kishore, P. R. S., Becker, D. P., Ward, J. D., Enas, G. G., Greenberg, R. P., Da Silva, A. D., Lipper, M. H., Choi, S. C., Mayhall, C. G., et al. (1982) · Journal of Neurosurgery · doi:10.3171/jns.1982.56.5.0650 · Cited by 591
Bouma, G. J., Muizelaar, J. P., Stringer, W. A., Choi, S. C., Fatouros, P., & Young, H. F. (1992) · Journal of Neurosurgery · doi:10.3171/jns.1992.77.3.0360 · Cited by 549
Smith, D. S. (1993) · Journal of Neurosurgical Anesthesiology · doi:10.1097/00008506-199301000-00013 · Cited by 467
Jugular venous desaturation and outcome after head injury.
Gopinath, S. P., Robertson, C. S., Contant, C. F., Hayes, C., Feldman, Z., Narayan, R. K., & Grossman, R. G. (1994) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.57.6.717 · Cited by 442
Continuous monitoring of jugular venous oxygen saturation in head-injured patients
Sheinberg, M., Kanter, M. J., Robertson, C. S., Contant, C. F., Narayan, R. K., & Grossman, R. G. (1992) · Journal of Neurosurgery · doi:10.3171/jns.1992.76.2.0212 · Cited by 422
Acute regional cerebral blood flow changes caused by severe head injuries
Marion, D. W., Darby, J., & Yonas, H. (1991) · Journal of Neurosurgery · doi:10.3171/jns.1991.74.3.0407 · Cited by 410
Kiening, K. L., Unterberg, A. W., Bardt, T. F., Schneider, G.-H., & Lanksch, W. R. (1996) · Journal of Neurosurgery · doi:10.3171/jns.1996.85.5.0751 · Cited by 408
Cited by
The role of hypoxia in cancer progression, angiogenesis, metastasis, and resistance to therapy
Muz, B., de la Puente, P., Azab, F., & Azab, A. K. (2015) · Hypoxia · doi:10.2147/hp.s93413 · Cited by 2,066
Oxygen in Stem Cell Biology: A Critical Component of the Stem Cell Niche
Mohyeldin, A., Garzón-Muvdi, T., & Quiñones-Hinojosa, A. (2010) · Cell Stem Cell · doi:10.1016/j.stem.2010.07.007 · Cited by 1,535
Why is the partial oxygen pressure of human tissues a crucial parameter? Small molecules and hypoxia
Carreau, A., Hafny‐Rahbi, B. E., Matejuk, A., Grillon, C., & Kieda, C. (2011) · Journal of Cellular and Molecular Medicine · doi:10.1111/j.1582-4934.2011.01258.x · Cited by 1,246
“[56] in 1998 undertook complete monitoring of brain tissue pO2 as a function of the depth underneath the dura level.”
BackgroundHall, C. N., Klein-Flugge, M. C., Howarth, C., & Attwell, D. (2012) · Journal of Neuroscience · doi:10.1523/jneurosci.0026-12.2012 · Cited by 451
Stiefel, M. F., Spiotta, A., Gracias, V. H., Garuffe, A. M., Guillamondegui, O., Maloney-Wilensky, E., Bloom, S., Grady, M. S., & LeRoux, P. D. (2005) · Journal of Neurosurgery · doi:10.3171/jns.2005.103.5.0805 · Cited by 429
What is the real physiological NO concentration in vivo?
Hall, C. N., & Garthwaite, J. (2009) · Nitric Oxide · doi:10.1016/j.niox.2009.07.002 · Cited by 378
“(2)) within the physiological O2 range (20–150 lM [82,83]; Fig.”
BackgroundDiffusion limited oxygen delivery following head injury*
Menon, D. K., Coles, J. P., Gupta, A. K., Fryer, T. D., Smielewski, P., Chatfield, D. A., Aigbirhio, F., Skepper, J. N., Minhas, P. S., Hutchinson, P. J., et al. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000127777.16609.08 · Cited by 340
Keeley, T. P., & Mann, G. E. (2019) · Physiological Reviews · doi:10.1152/physrev.00041.2017 · Cited by 329
Connecting the Chemical and Biological Properties of Nitric Oxide
Toledo, J. C., & Augusto, O. (2012) · Chemical Research in Toxicology · doi:10.1021/tx300042g · Cited by 286
Narotam, P. K., Morrison, J. F., & Nathoo, N. (2009) · Journal of Neurosurgery · doi:10.3171/2009.4.jns081150 · Cited by 279
The role of oxygen in regulating neural stem cells in development and disease
Panchision, D. M. (2009) · Journal of Cellular Physiology · doi:10.1002/jcp.21812 · Cited by 250
“Similarly, measurements in human brain show a mean PO2 varying from 3.2% (23.8 8.1 mm Hg) at 22–27 mm below the dura to 4.4% (33.3 13.3 mm Hg) at 7–12 mm below the dura (Dings et al., 1998).”
BackgroundInfluentialMcCord, A. M., Jamal, M., Shankavarum, U. T., Lang, F. F., Camphausen, K., & Tofilon, P. J. (2009) · Molecular Cancer Research · doi:10.1158/1541-7786.mcr-08-0360 · Cited by 239
“However, whereas alveolar oxygen concentration is ∼14% (12), normal brain oxygen levels range from 5% to 10% (13, 14).”
BackgroundSpiotta, A. M., Stiefel, M. F., Gracias, V. H., Garuffe, A. M., Kofke, W. A., Maloney-Wilensky, E., Troxel, A. B., Levine, J. M., & Le Roux, P. D. (2010) · Journal of Neurosurgery · doi:10.3171/2010.1.jns09506 · Cited by 238
Brain tissue oxygen and outcome after severe traumatic brain injury: A systematic review*
Maloney-Wilensky, E., Gracias, V., Itkin, A., Hoffman, K., Bloom, S., Yang, W., Christian, S., & LeRoux, P. D. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181a009f8 · Cited by 238
Vajkoczy, P., Roth, H., Horn, P., Lucke, T., Thomé, C., Hubner, U., Martin, G. T., Zappletal, C., Klar, E., Schilling, L., et al. (2000) · Journal of Neurosurgery · doi:10.3171/jns.2000.93.2.0265 · Cited by 229
The Meaning, Measurement and Modification of Hypoxia in the Laboratory and the Clinic
Hammond, E. M., Asselin, M.-C., Forster, D., O'Connor, J. P. B., Senra, J. M., & Williams, K. J. (2014) · Clinical Oncology · doi:10.1016/j.clon.2014.02.002 · Cited by 217
Relevance of Oxygen Concentration in Stem Cell Culture for Regenerative Medicine
Mas-Bargues, C., Sanz-Ros, J., Román-Domínguez, A., Inglés, M., Gimeno-Mallench, L., El Alami, M., Viña-Almunia, J., Gambini, J., Viña, J., & Borrás, C. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20051195 · Cited by 215
Jaeger, M., Schuhmann, M. U., Soehle, M., & Meixensberger, J. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000218413.51546.9e · Cited by 214
“Because PtiO2 monitoring is an invasive tool, it carries the potential risk of complications such as probe-induced hemorrhages or infection, but reported rates of complications are very low and we did not observe any such problems in our study (9).”
BackgroundSelf-citationBrain tissue oxygen guided treatment supplementing ICP/CPP therapy after traumatic brain injury
Meixensberger, J. (2003) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.74.6.760 · Cited by 190
Self-citationPhysiologic and functional outcome correlates of brain tissue hypoxia in traumatic brain injury*
Chang, J. J. J., Youn, T. S., Benson, D., Mattick, H., Andrade, N., Harper, C. R., Moore, C. B., Madden, C. J., & Diaz-Arrastia, R. R. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e318192fbd7 · Cited by 177
“First, previous studies have shown that BTpO2 values 10 mm Hg as well as prolonged values below 15 mm Hg were associated with high mortality (11, 22).”
BackgroundMolecular targeting of hypoxia in radiotherapy
Rey, S., Schito, L., Koritzinsky, M., & Wouters, B. G. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.10.002 · Cited by 172
Pistollato, F., Chen, H.-L., Schwartz, P. H., Basso, G., & Panchision, D. M. (2007) · Molecular and Cellular Neuroscience · doi:10.1016/j.mcn.2007.04.003 · Cited by 158
“Measurements in human brain show a mean PO 2 varying from 3.2% (23.8 ± 8.1 mm Hg) at 22–27 mm below the dura to 4.4% (33.3 ± 13.3 mm Hg) at 7–12 mm below the dura (Dings et al., 1998).”
BackgroundInfluentialHypoxia and the phenomenon of immune exclusion
Pietrobon, V., & Marincola, F. M. (2021) · Journal of Translational Medicine · doi:10.1186/s12967-020-02667-4 · Cited by 119
Stress-induced (Premature) senescence
Debacq-Chainiaux, F., Ben Ameur, R., Bauwens, E., Dumortier, E., Toutfaire, M., & Toussaint, O. (2016) · Healthy Ageing and Longevity · doi:10.1007/978-3-319-26239-0_13 · Cited by 31
“However, in vivo, cells are exposed to a reduced oxygen concentration ranging between tissues from 3 to 4 % in the brain (Dings et al. 1998), 3–7 % in the muscles (Vedsted et al.”
BackgroundWesseler, M. F., Johansen, M. N., Kızıltay, A., Mortensen, K. I., & Larsen, N. B. (2022) · Lab on a Chip · doi:10.1039/d2lc00063f · Cited by 19
Metadata
- Authors
- Dings, J., Meixensberger, J., Jäger, A., & Roosen, K.
- Venue
- Neurosurgery
- Published
- 1998-11
- Volume
- 43
- Issue
- 5
- Pages
- 1082-1094
- ISSN
- 0148-396X (ISSN-L)
- 1524-4040
- OpenAlex
- W2077067643
- Cited by
- 323
- References
- 28
- FWCI
- 4.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.