A Randomized Prospective Study of Polyglycolic Acid Conduits for Digital Nerve Reconstruction in Humans
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
This article reports the first randomized prospective multicenter evaluation of a bioabsorbable conduit for nerve repair. The study enrolled 98 subjects with 136 nerve transections in the hand and prospectively randomized the repair to two groups: standard repair, either end-to-end or with a nerve graft, or repair using a polyglycolic acid conduit. Two-point discrimination was measured by a blinded observer at 3, 6, 9, and 12 months after repair. There were 56 nerves repaired in the control group and 46 nerves repaired with a conduit available for follow-up. Three patients had a partial conduit extrusion as a result of loss of the initially crushed skin flap. The overall results showed no significant difference between the two groups as a whole. In the control group, excellent results were obtained in 43 percent of repairs, good results in 43 percent, and poor results in 14 percent. In those nerves repaired with a conduit, excellent results were obtained in 44 percent, good results in 30 percent, and poor results in 26 percent (p = 0.46). When the sensory recovery was examined with regard to length of nerve gap, however, nerves with gaps of 4 mm or less had better sensation when repaired with a conduit; the mean moving two-point discrimination was 3.7 +/- 1.4 mm for polyglycolic acid tube repair and 6.1 +/- 3.3 mm for end-to-end repairs (p = 0.03). All injured nerves with deficits of 8 mm or greater were reconstructed with either a nerve graft or a conduit. This subgroup also demonstrated a significant difference in favor of the polyglycolic acid tube. The mean moving two-point discrimination for the conduit was 6.8 +/- 3.8 mm, with excellent results obtained in 7 of 17 nerves, whereas the mean moving two-point discrimination for the graft repair was 12.9 +/- 2.4 mm, with excellent results obtained in none of the eight nerves (p < 0.001 and p = 0.06, respectively). This investigation demonstrates improved sensation when a conduit repair is used for nerve gaps of 4 mm or less, compared with end-to-end repair of digital nerves. Polyglycolic acid conduit repair also produces results superior to those of a nerve graft for larger nerve gaps and eliminates the donor-site morbidity associated with nerve-graft harvesting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical Nerve Reconstruction with a Bioabsorbable Polyglycolic Acid Tube
Mackinnon, S. E., & Dellon, A. L. (1990) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-199003000-00015 · Cited by 535
Chronic Nerve Compression—an Experimental Model in the Rat
Mackinnon, S. E., Dellon, A. L., Hudson, A. R., & Hunter, D. A. (1984) · Annals of Plastic Surgery · doi:10.1097/00000637-198408000-00004 · Cited by 307
An Alternative to the Classical Nerve Graft for the Management of the Short Nerve Gap
Dellon, A. L., & Mackinnon, S. E. (1988) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-198811000-00020 · Cited by 292
Chiu, D. T. W., & Strauch, B. (1990) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-199011000-00015 · Cited by 259
In Vivo Regeneration of Cut Nerves Encased in Silicone Tubes: Growth across a Six-millimeter Gap
LUNDBORG, G., GELBERMAN, R. H., LONGO, F. M., POWELL, H. C., & VARON, S. (1982) · Journal of Neuropathology and Experimental Neurology · doi:10.1097/00005072-198207000-00004 · Cited by 243
Degradable implant materials: A review of synthetic absorbable polymers and their applications
Barrows, T. (1986) · Clinical Materials · doi:10.1016/s0267-6605(86)80015-4 · Cited by 215
Polyglycolic Acid Sutures: Laboratory and Clinical Evaluation of a New Absorbable Suture Material
Herrmann, J. B. (1970) · Archives of Surgery · doi:10.1001/archsurg.1970.01340220162027 · Cited by 202
Selective reinnervation of distal motor stumps by peripheral motor axons
Brushart, T. M. E., & Seiler, W. A. (1987) · Experimental Neurology · doi:10.1016/0014-4886(87)90090-2 · Cited by 198
Anatomy of the sural nerve complex
Ortigiiela, M. E., Wood, M. B., & Cahill, D. R. (1987) · The Journal of Hand Surgery · doi:10.1016/s0363-5023(87)80129-6 · Cited by 193
Regeneration of peripheral nerve through a polyglactin tube
Molander, H., Olsson, Y., Engkvist, O., Bowald, S., & Eriksson, I. (1982) · Muscle & Nerve · doi:10.1002/mus.880050110 · Cited by 186
Cited by
Challenges in tissue engineering
Ikada, Y. (2006) · Journal of The Royal Society Interface · doi:10.1098/rsif.2006.0124 · Cited by 919
Kehoe, S., Zhang, X. F., & Boyd, D. (2012) · Injury · doi:10.1016/j.injury.2010.12.030 · Cited by 725
Neural tissue engineering options for peripheral nerve regeneration
Gu, X., Ding, F., & Williams, D. F. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.04.064 · Cited by 630
“Birmingham, AL [33,35,36,40,43,45,51,52,56]”
Gu, X., Ding, F., Yang, Y., & Liu, J. (2011) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2010.11.002 · Cited by 583
Repairing injured peripheral nerves: Bridging the gap
Deumens, R., Bozkurt, A., Meek, M. F., Marcus, M. A. E., Joosten, E. A. J., Weis, J., & Brook, G. A. (2010) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2010.10.002 · Cited by 510
Chapter 8 Current Techniques and Concepts in Peripheral Nerve Repair
Siemionow, M., & Brzezicki, G. (2009) · International Review of Neurobiology · doi:10.1016/s0074-7742(09)87008-6 · Cited by 453
Peripheral nerve regeneration through guidance tubes
Belkas, J. S., Shoichet, M. S., & Midha, R. (2004) · Neurological Research · doi:10.1179/016164104225013798 · Cited by 415
Biomaterials for the Development of Peripheral Nerve Guidance Conduits
Nectow, A. R., Marra, K. G., & Kaplan, D. L. (2012) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2011.0240 · Cited by 395
Current applications and future perspectives of artificial nerve conduits
Jiang, X., Lim, S. H., Mao, H.-Q., & Chew, S. Y. (2010) · Experimental Neurology · doi:10.1016/j.expneurol.2009.09.009 · Cited by 394
Pfister, B. J., Gordon, T., Loverde, J. R., Kochar, A. S., Mackinnon, S. E., & Cullen, D. K. (2011) · Critical Reviews™ in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v39.i2.20 · Cited by 358
Designing ideal conduits for peripheral nerve repair
de Ruiter, G. C. W., Malessy, M. J. A., Yaszemski, M. J., Windebank, A. J., & Spinner, R. J. (2009) · Neurosurgical Focus · doi:10.3171/foc.2009.26.2.e5 · Cited by 352
Battiston, B., Geuna, S., Ferrero, M., & Tos, P. (2005) · Microsurgery · doi:10.1002/micr.20127 · Cited by 346
Biocompatibility evaluation of silk fibroin with peripheral nerve tissues and cells in vitro
Yang, Y., Chen, X., Ding, F., Zhang, P., Liu, J., & Gu, X. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.12.004 · Cited by 333
Brooks, D. N., Weber, R. V., Chao, J. D., Rinker, B. D., Zoldos, J., Robichaux, M. R., Ruggeri, S. B., Anderson, K. A., Bonatz, E. E., Wisotsky, S. M., et al. (2012) · Microsurgery · doi:10.1002/micr.20975 · Cited by 329
Self-citationPeripheral Nerve Repair and Reconstruction
Griffin, J. W., Hogan, M. V., Chhabra, A. B., & Deal, D. N. (2013) · The Journal of Bone & Joint Surgery · doi:10.2106/jbjs.l.00704 · Cited by 310
Nerve conduits and growth factor delivery in peripheral nerve repair
Pfister, L. A., Papaloïzos, M., Merkle, H. P., & Gander, B. (2007) · Journal of the Peripheral Nervous System · doi:10.1111/j.1529-8027.2007.00125.x · Cited by 294
Wang, X., Hu, W., Cao, Y., Yao, J., Wu, J., & Gu, X. (2005) · Brain · doi:10.1093/brain/awh517 · Cited by 292
Meek, M. F., & Coert, J. H. (2008) · Annals of Plastic Surgery · doi:10.1097/sap.0b013e31804d441c · Cited by 271
Nerve Repair by Means of Tubulization: Past, Present, Future
Konofaos, P., & Ver Halen, J. (2013) · Journal of Reconstructive Microsurgery · doi:10.1055/s-0032-1333316 · Cited by 269
Limitations of Conduits in Peripheral Nerve Repairs
Moore, A. M., Kasukurthi, R., Magill, C. K., Farhadi, H. F., Borschel, G. H., & Mackinnon, S. E. (2009) · HAND · doi:10.1007/s11552-008-9158-3 · Cited by 268
Synthetic Nerve Guide Implants in Humans: A Comprehensive Survey
Schlosshauer, B., Dreesmann, L., Schaller, H.-E., & Sinis, N. (2006) · Neurosurgery · doi:10.1227/01.neu.0000235197.36789.42 · Cited by 245
Karabekmez, F. E., Duymaz, A., & Moran, S. L. (2009) · HAND · doi:10.1007/s11552-009-9195-6 · Cited by 243
“The results of this study have shown nerve recovery which is comparable to previous reports of primary nerve repair as well as nerve repair with conduits [1, 3, 4, 7, 17, 30].”
Bertleff, M. J. O. E., Meek, M. F., & Nicolai, J.-P. A. (2005) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.12.009 · Cited by 233
Ichihara, S., Inada, Y., & Nakamura, T. (2008) · Injury · doi:10.1016/j.injury.2008.08.029 · Cited by 222
Next Generation Nerve Guides: Materials, Fabrication, Growth Factors, and Cell Delivery
Bell, J. H. A., & Haycock, J. W. (2012) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2011.0498 · Cited by 208
Gaudin, R., Knipfer, C., Henningsen, A., Smeets, R., Heiland, M., & Hadlock, T. (2016) · BioMed Research International · doi:10.1155/2016/3856262 · Cited by 207
“found in a randomized prospective multicenter evaluation of digital nerve repair that PGA conduits were equivalent or superior to traditional autografts for reconstruction of long sensory nerve gaps up to 3 cm [72].”
BackgroundGrowth factor enhancement of peripheral nerve regeneration through a novel synthetic hydrogel tube
Midha, R., Munro, C. A., Dalton, P. D., Tator, C. H., & Shoichet, M. S. (2003) · Journal of Neurosurgery · doi:10.3171/jns.2003.99.3.0555 · Cited by 207
Defining and designing polymers and hydrogels for neural tissue engineering
Aurand, E. R., Lampe, K. J., & Bjugstad, K. B. (2012) · Neuroscience Research · doi:10.1016/j.neures.2011.12.005 · Cited by 206
Past, Present, and Future of Nerve Conduits in the Treatment of Peripheral Nerve Injury
Muheremu, A., & Ao, Q. (2015) · BioMed Research International · doi:10.1155/2015/237507 · Cited by 199
“[16] performed a randomized controlled study of 136 patientswith peripheral nerve injury in 5USmedical centers.”
MethodChitosan-film enhanced chitosan nerve guides for long-distance regeneration of peripheral nerves
Meyer, C., Stenberg, L., Gonzalez-Perez, F., Wrobel, S., Ronchi, G., Udina, E., Suganuma, S., Geuna, S., Navarro, X., Dahlin, L. B., et al. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2015.10.040 · Cited by 181
“size of endoneurial tubes) and mismatch in Schwann cell phenotypes (sensory vs motor nerve peripheral glia cells) [4].”
Schwann cell delivery of neurotrophic factors for peripheral nerve regeneration
Madduri, S., & Gander, B. (2010) · Journal of the Peripheral Nervous System · doi:10.1111/j.1529-8027.2010.00257.x · Cited by 177
“Artificial nerve conduits (NC) were introduced as a promising alternative to autologus nerve grafts for bridging nerve gaps of typically 3–10 mm (Lundborg et al., 1982; Archibald et al., 1991; Weber et al., 2000).”
BackgroundBozkurt, A., Deumens, R., Beckmann, C., Olde Damink, L., Schügner, F., Heschel, I., Sellhaus, B., Weis, J., Jahnen-Dechent, W., Brook, G. A., et al. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.09.017 · Cited by 176
Scaffolds for peripheral nerve repair and reconstruction
Yi, S., Xu, L., & Gu, X. (2019) · Experimental Neurology · doi:10.1016/j.expneurol.2018.05.016 · Cited by 172
Chitosan tubes of varying degrees of acetylation for bridging peripheral nerve defects
Haastert-Talini, K., Geuna, S., Dahlin, L. B., Meyer, C., Stenberg, L., Freier, T., Heimann, C., Barwig, C., Pinto, L. F. V., Raimondo, S., et al. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.08.074 · Cited by 170
“Conduits, which are approved by the Food and Drug Administration (FDA) and authorized by the EC respectively, include Neurotube poly(glycolide) (PGA) tubes (successfully used in the clinical repair of digital nerves with defects of up to 3 cm in length [7]), Neura-Gen collagen nerve tubes [8,9], and Neurolac tubes [10…”
BackgroundNakamura, T., Inada, Y., Fukuda, S., Yoshitani, M., Nakada, A., Itoi, S.-I., Kanemaru, S.-I., Endo, K., & Shimizu, Y. (2004) · Brain Research · doi:10.1016/j.brainres.2004.08.040 · Cited by 165
Olson, H. E., Rooney, G. E., Gross, L., Nesbitt, J. J., Galvin, K. E., Knight, A., Chen, B., Yaszemski, M. J., & Windebank, A. J. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2008.0364 · Cited by 163
“5,10,15 Multilumen scaffolds have the mechanical and physical attributes to provide an appropriate microenvironment for re-generation.”
Techniques of Peripheral Nerve Repair
Dahlin, L. B. (2008) · Scandinavian Journal of Surgery · doi:10.1177/145749690809700407 · Cited by 163
Yang, C.-Y., Huang, W.-Y., Chen, L.-H., Liang, N.-W., Wang, H.-C., Lu, J., Wang, X., & Wang, T.-W. (2021) · Journal of Materials Chemistry B · doi:10.1039/d0tb01605e · Cited by 161
Collagen Tube Conduits in Peripheral Nerve Repair: A Retrospective Analysis
Wangensteen, K. J., & Kalliainen, L. K. (2010) · HAND · doi:10.1007/s11552-009-9245-0 · Cited by 161
“A multicenter study of 136 nerve repairs suggested that PGA conduits are at least as effective as nerve grafting for repairing avulsed nerves, with 44% having excellent results, 30% having good results, and 26% having poor results [12].”
BackgroundAn aligned 3D neuronal-glial co-culture model for peripheral nerve studies
Daud, M. F. B., Pawar, K. C., Claeyssens, F., Ryan, A. J., & Haycock, J. W. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.05.008 · Cited by 158
“to autografting for small nerve gaps [6,7], but typically restricted to a regeneration distance of just a few millimetres [8].”
BackgroundNerve conduits for nerve repair or reconstruction
Deal, N. D., Griffin, J. W., & Hogan, M. V. (2012) · Journal of the American Academy of Orthopaedic Surgeons · doi:10.5435/jaaos-20-02-063 · Cited by 126
Update in facial nerve paralysis: tissue engineering and new technologies
Langhals, N. B., Urbanchek, M. G., Ray, A., & Brenner, M. J. (2014) · Current Opinion in Otolaryngology & Head and Neck Surgery · doi:10.1097/moo.0000000000000062 · Cited by 41
DADACI, M., KARAGÜLLE, N., SÖNMEZ, E., DADACI, Z., İŞCİ, E. T., İNCE, B., VARGEL, İ., PİŞKİN, E., & ERK, A. Y. (2016) · TURKISH JOURNAL OF MEDICAL SCIENCES · doi:10.3906/sag-1412-110 · Cited by 7
Metadata
- Authors
- Weber, R. A., Breidenbach, W. C., Brown, R. E., Jabaley, M. E., & Mass, D. P.
- Venue
- Plastic and Reconstructive Surgery
- Published
- 2000-10
- Volume
- 106
- Issue
- 5
- Pages
- 1036-1045
- ISSN
- 0032-1052 (ISSN-L)
- OpenAlex
- W2048670135
- Cited by
- 552
- References
- 21
- FWCI
- 9.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.