Interbody Lumbar Fusion Using a Carbon Fiber Cage Implant Versus Allograft Bone: An Investigational Study in the Spanish Goat
The DOI matches its Crossref record.
Abstract
STUDY DESIGN: A carbon fiber-reinforced polymer implant, designed to aid interbody lumbar fusion, was tested biologically in an experimental surgical model. Twenty-seven Spanish goats had interbody lumbar fusion surgery in a randomized protocol. Seventeen goats were implanted with the carbon fiber-reinforced polymer cage packed with autologous bone, and 10 goats were implanted with ethylene oxide-sterilized allograft bone. OBJECTIVES: To determine fusion success, biocompatibility of the carbon polymer material, and possibility of carbon wear debris at intervals after surgical implantation. METHODS: Goats were killed at 6 months, 12 months, and 24 months and full-body autopsies were done. Spine specimens were studied by plain radiography, three-dimensional reformatted computed tomography studies, and histology. RESULTS: At 6 months, one of three allograft implantations showed histologic and radiographic fusion, whereas five of five carbon fiber-reinforced polymer cage fusions showed at least partial fusion. At 12 months, two of three allograft implantations and five of five carbon fiber-reinforced polymer cage fusions were solidly fused. At 24 months, five of five allograft implantations and three of three carbon fiber-reinforced polymer cage implantations were solidly fused. CONCLUSIONS: Interbody fusion using a carbon cage implant packed with autologous bone achieved a quicker and more reliable fusion compared with ethylene oxide-sterilized allograft bone. There were no adverse effects from the implant material.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
PEEK biomaterials in trauma, orthopedic, and spinal implants
Kurtz, S. M., & Devine, J. N. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.07.013 · Cited by 2,388
Brantigan, J. W., Steffee, A. D., Lewis, M. L., Quinn, L. M., & Persenaire, J. M. (2000) · Spine · doi:10.1097/00007632-200006010-00017 · Cited by 348
Self-citationBono, C. M., & Lee, C. K. (2004) · Spine · doi:10.1097/01.brs.0000090825.94611.28 · Cited by 330
Current Concepts Review - Interbody Fusion Cages in Reconstructive Operations on the Spine*
MCAFEE, P. C. (1999) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199906000-00014 · Cited by 306
Self-citationWeiner, B. K., & Fraser, R. D. (1998) · Spine · doi:10.1097/00007632-199803010-00020 · Cited by 242
McAfee, P. C., Regan, J. J., Geis, W. P., & Fedder, I. L. (1998) · Spine · doi:10.1097/00007632-199807010-00009 · Cited by 232
Self-citationChristensen, F. B., Hansen, E. S., Eiskjær, S. P., Høy, K., Helmig, P., Neumann, P., Niedermann, B., & Bünger, C. E. (2002) · Spine · doi:10.1097/00007632-200212010-00006 · Cited by 202
“The vessels were protected by rubber-coated Steinmann pins, and ALIF Brantigan cages (9, 11, or 13 mm) were carefully placed according to guidelines established by Brantigan et al.4 Antibiotic prophylaxis or thrombosis prophylaxis was used.”
MethodPlasma-sprayed titanium coating to polyetheretherketone improves the bone-implant interface
Walsh, W. R., Bertollo, N., Christou, C., Schaffner, D., & Mobbs, R. J. (2015) · The Spine Journal · doi:10.1016/j.spinee.2014.12.018 · Cited by 197
“Developments starting from stainless steel cages [5,6] to carbon fiber implants [7,8] and degradable polylactides [9,10] have provided some improvements and increased understanding of the complexity of interbody fusion.”
BackgroundVillavicencio, A. T., Burneikiene, S., Nelson, E. L., Bulsara, K. R., Favors, M., & Thramann, J. (2005) · Journal of Neurosurgery: Spine · doi:10.3171/spi.2005.3.6.0436 · Cited by 188
Saito, N., Aoki, K., Usui, Y., Shimizu, M., Hara, K., Narita, N., Ogihara, N., Nakamura, K., Ishigaki, N., Kato, H., et al. (2011) · Chemical Society Reviews · doi:10.1039/c0cs00120a · Cited by 183
Polyetheretherketone (PEEK) cages in cervical applications: a systematic review
Kersten, R. F. M. R., van Gaalen, S. M., de Gast, A., & Öner, F. C. (2015) · The Spine Journal · doi:10.1016/j.spinee.2013.08.030 · Cited by 177
“In addition, an animal study was performed in which Spanish goats received either a PEKEKK cage with autologous iliac crest graft (CFRP cage) or allograft bone blocks [30].”
van Dijk, M., Smit, T. H., Sugihara, S., Burger, E. H., & Wuisman, P. I. (2002) · Spine · doi:10.1097/00007632-200204010-00003 · Cited by 165
In vitro and in vivo degradation of bioabsorbable PLLA spinal fusion cages
van Dijk, M., Tunc, D. C., Smit, T. H., Higham, P., Burger, E. H., & Wuisman, P. I. J. M. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10466 · Cited by 78
Metadata
- Authors
- Brantigan, J. W., McAfee, P. C., Cunningham, B. W., Wang, H., & Orbegoso, C. M.
- Venue
- Spine
- Published
- 1994-07
- Volume
- 19
- Issue
- 13
- Pages
- 1436-1443
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W1981476160
- Cited by
- 182
- References
- 0
- FWCI
- 1.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.